1. Product Overview
The uxcell Key Switch is designed for access control systems, functioning as an emergency exit switch. It features a mechanical key for operation and includes an LED indicator that changes color based on the switch's state. This SPST (Single Pole Single Throw) switch is suitable for regulating entry and exit in various applications.
The key is removable in both ON and OFF positions, providing flexibility in operation. The anti-disassembly signal output enhances security.
2. Package Contents
Verify that all items listed below are included in your package:
- 1 x Key Operated Switch
- 2 x Keys
- 2 x Mounting Screws
3. Specifications
| Feature | Detail |
|---|---|
| Panel Material | 304 Stainless Steel |
| Switch Rated Power | 4A 125V AC / 2A 250V AC |
| Indicator Rated Voltage | DC 12V |
| Switch Type | SPST (Single Pole Single Throw) |
| Contacts Type | 1 NO (Normally Open), 1 NC (Normally Closed), 1 COM (Common), 2 TAMP (Tamper) |
| Panel Size (L*W) | 115 x 70mm / 4.53" x 2.76" |
| Mounting Cut Hole (L*W) | 54 x 36mm / 2.13" x 1.42" |
| Panel Mounting Hole Diameter | 4.5mm / 0.18" |
| Panel Mounting Hole Distance | 83mm / 3.27" |
| Operation Mode | ON-OFF |
| Mounting Type | Door Mount |
4. Setup and Installation
This key switch is designed for flush mounting on a door frame or wall. Ensure proper wiring and secure mounting for optimal performance and safety.
- Prepare Mounting Location: Identify a suitable location for the switch. The mounting cut hole dimensions are 54 x 36mm (2.13" x 1.42"). Ensure there is enough space behind the panel for wiring.
- Cut Mounting Hole: Carefully cut a rectangular hole of 54 x 36mm (2.13" x 1.42") in the desired mounting surface.
- Mount the Switch: Insert the key switch assembly into the cut hole. Align the mounting holes on the panel with the pre-drilled holes (4.5mm / 0.18" diameter, 83mm / 3.27" distance). Secure the panel using the provided mounting screws.
- Wiring Connections:
The switch has contacts for NO (Normally Open), NC (Normally Closed), COM (Common), and TAMP (Tamper). Refer to your access control system's wiring diagram for specific connections.
- NO-COM Configuration: When the switch is ON, the GREEN indicator will be ON. When the switch is OFF, the RED indicator will be ON.
- NC-COM Configuration: When the switch is ON, the RED indicator will be ON. When the switch is OFF, the GREEN indicator will be ON.
Connect the DC 12V power supply to the indicator terminals as required. Ensure all connections are secure and insulated.
- Test Functionality: After wiring, test the switch operation with the provided keys and verify the LED indicator's behavior according to your chosen configuration.

Figure 1: Front view of the uxcell Key Switch, showing overall dimensions and keyhole placement. The panel measures 115mm x 70mm, with mounting holes 83mm apart and 4.5mm in diameter. The key switch barrel is 19mm.

Figure 2: Rear view of the uxcell Key Switch, illustrating the wiring terminals (NO, NC, COM, TAMP) and the 19mm barrel diameter. Proper connection to these terminals is crucial for functionality.
5. Operating Instructions
The uxcell Key Switch operates as a simple ON-OFF mechanism for your access control system.
- Insert Key: Insert one of the provided keys into the keyhole.
- Turn to ON/OFF: Rotate the key to the desired position (ON or OFF). The key is removable in both positions.
- Observe LED Indicator: The integrated LED indicator will change color to reflect the switch's state.
- For NO-COM wiring: Green indicates ON, Red indicates OFF.
- For NC-COM wiring: Red indicates ON, Green indicates OFF.
- Remove Key: Once the desired state is set, the key can be removed.
Video 1: Demonstration of a similar 12mm metal key lock switch, showing the key insertion, turning action, and the LED indicator changing color. This illustrates the basic operation of such key switches.
6. Maintenance
The uxcell Key Switch requires minimal maintenance to ensure long-term reliability.
- Cleaning: Periodically wipe the stainless steel panel with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the finish or internal components.
- Key Care: Keep keys clean and free from debris. Do not force the key if it feels stiff; apply a small amount of graphite lubricant if necessary.
- Connection Check: Annually inspect wiring connections to ensure they remain secure and free from corrosion.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Switch does not activate/deactivate access control. | Incorrect wiring; loose connections; faulty access control system. | Verify wiring against your system's diagram. Ensure all terminals are securely connected. Test the access control system independently. |
| LED indicator does not light up or changes color incorrectly. | Incorrect DC 12V power connection to indicator; faulty LED; incorrect wiring for NO/NC-COM. | Check the DC 12V power supply to the indicator. Confirm correct NO-COM or NC-COM wiring based on desired LED behavior. |
| Key is difficult to turn or remove. | Debris in keyhole; worn key/lock mechanism. | Clean the keyhole. Apply a small amount of graphite lubricant. If the issue persists, the mechanism may be worn and require replacement. |
8. Warranty and Support
For warranty information or technical support, please contact uxcell customer service through their official website or the retailer where the product was purchased. Please have your model number (a190111900ux0754) and purchase details ready.
You can visit the uxcell store for more products and support: uxcell Store