TOPGREENER TDHS5
TOPGREENER TDHS5 Humidity Sensor Switch User Manual
Model: TDHS5-N
Brand: TOPGREENER
Introduction
The TOPGREENER TDHS5 Humidity Sensor Switch is designed to automatically control your ventilation fan based on ambient humidity levels. This device is ideal for high-humidity environments such as bathrooms, laundry rooms, and basements, helping to prevent issues like mold, mildew, and paint peeling by ensuring proper ventilation. It features adjustable humidity sensitivity and a manual override for convenience.
Figure 1: Front view of the TOPGREENER TDHS5 Humidity Sensor Switch.
Product Features
- Automated Humidity Detection: Automatically turns the ventilation fan ON when humidity exceeds a preset level and OFF when it drops, eliminating excess moisture.
- Adjustable Humidity Levels: Offers three sensitivity settings (low, medium, high) to customize ventilation based on room needs.
- Manual ON/OFF Switch: Allows for manual control of the fan, bypassing the humidity sensor when desired.
- Time Delay: Features a 20-minute time delay for efficient operation.
- Neutral Wire Required: Designed for installations requiring a neutral wire.
- UL Listed: Ensures safety and quality standards are met.
- LED Indicator: An LED light illuminates when the fan is in use.
Figure 2: Key components of the TDHS5 switch, including the humidity sensor and fan switch.
Setup and Installation
Important Safety Information: Installation should only be performed by a qualified electrician or a knowledgeable individual familiar with electrical wiring. Always turn off power at the circuit breaker before beginning any electrical work to prevent electric shock.
Wiring Requirements:
- Neutral Wire: A neutral wire is required for the operation of this switch. This is typically found in newer homes.
- Voltage: 120VAC.
- Maximum Fan Load: 3A.
- Single-Pole Use Only: This switch is designed for single-pole applications.
Installation Steps:
- Turn Off Power: Locate the circuit breaker controlling the fan circuit and turn it OFF. Verify power is off using a voltage tester.
- Remove Old Switch: Carefully remove the existing wall plate and switch from the electrical box.
- Identify Wires: Identify the Line (hot), Load (to fan), Neutral, and Ground wires. The TDHS5 requires a neutral wire.
- Wire the Switch: Connect the wires to the TDHS5 switch terminals according to the wiring diagram provided with the product packaging. Ensure all connections are secure.
- Mount the Switch: Gently push the wired switch into the electrical box and secure it with screws.
- Install Wall Plate: Attach the new wall plate.
- Restore Power: Turn the power back ON at the circuit breaker.
Figure 3: The TDHS5 switch installed, emphasizing the neutral wire requirement for compatibility, typically in newer homes.
Operating Instructions
Automatic Humidity Control:
The TDHS5 switch will automatically activate the connected ventilation fan when it detects that the humidity level in the room exceeds the preset threshold. The fan will continue to run until the humidity drops below this level, after which it will turn off with a 20-minute time delay.
Figure 4: The TDHS5 switch in a bathroom, illustrating its use in high-humidity locations. The LED indicator lights up when the fan is active.
Adjusting Humidity Sensitivity (45%-80% range):
The switch offers three levels of humidity sensitivity: Low, Medium (default), and High. To change the setting:
- Step 1: Press and hold the fan button for 8 seconds until the fan indicator light illuminates. This indicates entry into the setting mode.
- Step 2: Press the fan button again to cycle through the modes:
- Press once for Low sensitivity.
- Press twice for Medium sensitivity (default).
- Press three times for High sensitivity.
- The selected setting will be saved automatically after a few seconds of inactivity.
Figure 5: Instructions for adjusting the humidity sensitivity levels (Low, Medium, High) on the TDHS5 switch.
Manual ON/OFF Operation:
To manually turn the fan ON or OFF, simply press the fan button. This will override the automatic humidity sensing until the next humidity cycle or manual intervention.
Figure 6: The TDHS5 switch installed in a laundry room, illustrating its function in detecting and managing humidity.
Maintenance
The TOPGREENER TDHS5 Humidity Sensor Switch requires minimal maintenance. Keep the surface of the switch clean by wiping it with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the humidity sensor vents are not obstructed by dust or debris, as this can affect its accuracy.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn ON automatically. |
|
|
| Fan runs continuously. |
|
|
| Manual ON/OFF button does not work. |
|
|
Specifications
| Attribute | Value |
|---|---|
| Model Number | TDHS5 |
| Operating Voltage | 120 VAC |
| Current Rating | 3 Amps (Max Fan Load) |
| Humidity Range | 45% - 80% |
| Time Delay | 20 minutes |
| Operation Mode | ON-NONE-ON |
| Contact Type | Normally Open |
| Connector Type | Screw Terminals |
| Circuit Type | 1-way (Single-Pole) |
| Actuator Type | Push Button |
| Material | Metal (Contact Material) |
| Certifications | UL Listed |
| Dimensions (Package) | 4.65 x 2.44 x 2.36 inches |
Warranty and Support
The TOPGREENER TDHS5 Humidity Sensor Switch comes with a 1-year warranty from the date of purchase. This warranty covers defects in material and workmanship under normal use.
For technical support, troubleshooting assistance, or warranty claims, please contact TOPGREENER customer service. Refer to the contact information provided on the product packaging or visit the official TOPGREENER website.
Manufacturer: Top Greener Inc
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.