1. Introduction
This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Sharp KC-G60EUW Air Purifier with Humidifier. Please read this manual thoroughly before using the appliance and keep it for future reference.
The Sharp KC-G60EUW is designed to purify and humidify the air in rooms up to 50 square meters. It features a 5-stage filtration system and Plasmacluster Ion technology to improve air quality by removing various pollutants, allergens, and odors.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.
- Ensure the power supply voltage matches the rating label on the unit.
- Do not operate the unit with a damaged power cord or plug.
- Keep the unit away from water and moisture. Do not immerse in water.
- Do not block air inlets or outlets.
- Unplug the unit before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Do not use the unit near flammable gases or combustible materials.
3. Product Overview
The Sharp KC-G60EUW combines air purification and humidification functions. Key components include the control panel, air inlets/outlets, water tank, and a multi-stage filter system.
3.1 Main Unit

Image 3.1: Front view of the Sharp KC-G60EUW Air Purifier, showing the Sharp logo and Plasmacluster ion indicator.

Image 3.2: Side view of the Sharp KC-G60EUW Air Purifier, illustrating its slim profile and power cord connection.
3.2 Control Panel
The control panel is located on the top of the unit and allows you to manage all functions.

Image 3.3: Top view of the Sharp KC-G60EUW, showing the control panel with various function buttons and indicators.

Image 3.4: Detailed view of the control panel buttons, including Power, Mode, Humidification, Spot, and Intelligent Auto mode.
3.3 Filtration System
The unit employs a 5-stage filtration system for comprehensive air purification:
- Pre-filter: Captures large particles like dust, hair, and pet dander (up to 240 microns).
- Carbon Filter with Silica Gel: Absorbs unpleasant odors, volatile organic compounds (VOCs) such as benzene, formaldehyde, and benzo(a)pyrene. The silica gel layer enhances the removal of nitrogen and sulfur oxides.
- HEPA H13 Filter: Removes 99.97% of PM 2.5 particles, pollen, and other fine airborne allergens.
- Humidifier Filter: Retains sediment from water, reducing scale buildup and ensuring clean humidification.
- Plasmacluster Ionizer: Generates positive and negative ions to neutralize airborne viruses, bacteria, mold spores, and odors.

Image 3.5: The multi-stage filtration system of the Sharp KC-G60EUW, showing the individual filters removed from the back of the unit.
4. Setup
Follow these steps to set up your air purifier for the first time:
- Unpack the Unit: Carefully remove the air purifier from its packaging. Retain packaging for future transport or storage.
- Remove Filter Packaging: Open the back cover of the unit. Remove all filters (pre-filter, carbon filter, HEPA filter) and unwrap them from their protective plastic bags. Reinstall the filters in the correct order, ensuring they are securely seated. Refer to Image 3.5 for filter arrangement.
- Fill Water Tank (for Humidification): Remove the water tank from the side of the unit. Fill it with clean tap water. Do not use distilled water or water with additives. Reinsert the water tank securely.
- Position the Unit: Place the air purifier on a flat, stable surface, ensuring there is adequate space (at least 20 cm) around the air inlets and outlets for optimal airflow.
- Connect Power: Plug the power cord into a suitable electrical outlet.
5. Operating Instructions
The Sharp KC-G60EUW offers various operating modes and settings.
5.1 Power On/Off
- Press the ON/OFF button on the control panel to turn the unit on or off.
5.2 Mode Selection
Press the MODE button to cycle through different purification modes:
- Auto Mode: The unit automatically adjusts fan speed and humidification based on sensor readings (dust, odor, humidity). This is the recommended mode for general use.
- Max Mode: Operates at maximum fan speed for rapid air purification.
- Med Mode: Medium fan speed for balanced purification.
- Low Mode: Low fan speed for quiet operation.
- Sleep Mode: Operates at the lowest fan speed with dimmed indicators for undisturbed sleep.
5.3 Humidification Function
To activate or deactivate humidification:
- Press the HUMIDIFY ON/OFF button. The humidification indicator will light up when active.
- Ensure the water tank is filled for humidification to function.
5.4 Plasmacluster Ion Function
The Plasmacluster Ion function is typically active by default. If there is a dedicated button, press the ION button to toggle it on or off. The Plasmacluster indicator will confirm its status.
5.5 Intelligent Auto Mode
Press the INTELLIGENT MODE button to engage the advanced automatic operation, which optimizes purification and humidification based on environmental conditions detected by the unit's sensors.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air purifier.
6.1 Cleaning the Pre-filter
- Frequency: Approximately once a month, or when the filter indicator lights up.
- Procedure:
- Unplug the unit.
- Remove the back panel.
- Carefully remove the pre-filter.
- Use a vacuum cleaner to remove dust and debris from the pre-filter. For stubborn dirt, wash it gently with water and a mild detergent. Rinse thoroughly and allow it to air dry completely before reinstalling.
- Reinstall the pre-filter and back panel.
6.2 Cleaning the Humidifier Filter and Water Tank
- Frequency: Weekly or as needed, especially if scale buildup is visible.
- Procedure:
- Unplug the unit.
- Remove the water tank and humidifier filter assembly.
- Empty any remaining water from the tank.
- Clean the water tank with a soft brush and mild detergent. Rinse thoroughly.
- Clean the humidifier filter by rinsing it under running water. For scale buildup, soak the filter in a descaling solution (e.g., citric acid solution) as per the solution's instructions, then rinse thoroughly.
- Allow all parts to air dry completely before reassembling and reinstalling.
6.3 HEPA and Carbon Filter Replacement
- Frequency: The HEPA and Carbon filters are not washable and must be replaced periodically. Refer to the filter replacement indicator on the unit or the manufacturer's recommendations (typically every 2-5 years depending on usage and air quality).
- Procedure:
- Unplug the unit.
- Remove the back panel and the old HEPA and Carbon filters.
- Install new, genuine Sharp replacement filters, ensuring correct orientation.
- Close the back panel.
- Reset the filter replacement indicator (refer to the control panel instructions, usually by pressing and holding a specific button for 3 seconds).
7. Troubleshooting
If you encounter issues with your Sharp KC-G60EUW, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power supply. | Check if the power cord is securely plugged into the unit and the wall outlet. Ensure the outlet is functional. |
| No humidification. | Water tank is empty or not properly installed. Humidification function is off. | Fill the water tank. Ensure the tank is correctly seated. Press the HUMIDIFY ON/OFF button. |
| Weak airflow or poor purification. | Filters are dirty or blocked. Air inlets/outlets are obstructed. | Clean the pre-filter. Check if HEPA/Carbon filters need replacement. Ensure no objects are blocking air vents. |
| Unusual noise. | Foreign object inside the unit. Filters not installed correctly. | Unplug the unit and check for any foreign objects. Reinstall filters correctly. If noise persists, contact customer support. |
| Odor persists. | Carbon filter is saturated. | Replace the carbon filter. |
If the problem persists after trying these solutions, please contact Sharp customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | KC-G60EUW |
| Brand | Sharp |
| Applicable Floor Area | Up to 50 m² (538 sq ft) |
| Max Purification Efficiency | 408 m³/h |
| Max Humidification Efficiency | 630 ml/h |
| Noise Level | 24 dB (minimum) |
| Filtration System | 5-stage (Pre-filter, Carbon, HEPA H13, Humidifier, Plasmacluster Ionizer) |
| Particle Retention (Pre-filter) | Up to 240 microns |
| Special Features | Plasmacluster Technology, Intelligent AUTO mode |
| Power Source | Corded Electric |
| Control Method | Remote Control, Button Control |
| Item Weight | 28.44 Pounds (approx. 12.9 kg) |
9. Warranty and Support
Sharp products are manufactured to high-quality standards and are warranted against manufacturing defects. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Sharp website for your region.
For technical assistance, troubleshooting beyond this manual, or to order replacement parts/filters, please contact Sharp customer support:
- Online Support: Visit the official Sharp support website.
- Phone Support: Refer to your product documentation or the Sharp website for local contact numbers.
- When contacting support, please have your model number (KC-G60EUW) and serial number ready.