1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Clivet EZCOOL 70M monosplit air conditioner. Please read this manual thoroughly before using the appliance and keep it for future reference. Proper use and maintenance will ensure optimal performance and longevity of your unit.
2. Safety Information
Always adhere to the following safety precautions to prevent injury, damage to property, or electric shock.
- Professional Installation: Installation, maintenance, and repair must be performed by qualified and authorized personnel only.
- Power Supply: Ensure the power supply matches the specifications of the unit. Do not use damaged power cords or plugs.
- Ventilation: Ensure proper ventilation around the outdoor unit to prevent overheating.
- Refrigerant: This unit uses R32 refrigerant. Handle with care and ensure proper disposal by certified technicians.
- Cleaning: Disconnect power before cleaning. Use a soft, dry cloth. Do not use water directly on the unit.
- Children and Pets: Keep children and pets away from the unit, especially during operation.
3. Product Overview
The Clivet EZCOOL 70M is a high-efficiency monosplit air conditioning system designed for optimal climate control. It consists of an indoor unit, an outdoor unit, and a remote control.

Image showing the complete Clivet EZCOOL 70M monosplit air conditioner system, including the indoor unit, outdoor unit, and remote control.

Front view of the Clivet EZCOOL 70M indoor unit, designed for wall mounting.

Front view of the Clivet EZCOOL 70M outdoor unit, featuring a large fan grille.

Lifestyle image depicting the Clivet EZCOOL 70M indoor unit installed in a living room setting, highlighting its integration with smart home devices and a 4-year warranty.
Key Features:
- Inverter Compressor: Provides energy-efficient and precise temperature control.
- R32 Refrigerant: Environmentally friendly refrigerant with lower global warming potential.
- Advanced Filtration: Features a high-density filter and a cold catalyst filter for improved air quality.
- Multiple Control Methods: Can be controlled via remote, app, and voice commands.
- Monosplit System: One indoor unit connected to one outdoor unit.
4. Setup and Installation
The installation of the Clivet EZCOOL 70M air conditioner requires specialized knowledge and tools. It is strongly recommended that installation be carried out by a certified HVAC professional to ensure safety, proper functioning, and compliance with local regulations.
General Installation Steps (for professional reference):
- Site Selection: Choose appropriate locations for both indoor and outdoor units, considering air circulation, drainage, and noise levels.
- Mounting: Securely mount the indoor unit on the wall and the outdoor unit on a stable surface or wall bracket.
- Piping Connection: Connect the refrigerant pipes between the indoor and outdoor units, ensuring no leaks.
- Electrical Wiring: Connect the power supply and communication cables according to the wiring diagram.
- Drainage: Install the condensate drain pipe to ensure proper water removal.
- Vacuuming and Refrigerant Charging: Evacuate the system to remove air and moisture, then charge with the correct amount of R32 refrigerant.
- Test Run: Perform a test run to verify all functions are operating correctly.
5. Operating Instructions
Remote Control Operation:
The remote control allows you to manage all functions of your air conditioner. Ensure the remote control is pointed towards the indoor unit when sending commands.
- Power Button: Turns the unit ON/OFF.
- Mode Button: Cycles through operating modes: Auto, Cool, Dry, Fan, Heat (if applicable).
- Temperature Buttons (▲/▼): Adjusts the desired temperature.
- Fan Speed Button: Adjusts the fan speed (Auto, Low, Medium, High).
- Swing Button: Controls the louver movement for air direction.
- Timer Button: Sets ON/OFF timers.
Smart Control (App/Voice):
The Clivet EZCOOL 70M supports control via a dedicated mobile application and voice commands through compatible smart home devices. Refer to the separate smart control setup guide for detailed instructions on connecting your unit to your home network and integrating with voice assistants.
6. Maintenance
Regular maintenance ensures the efficiency and longevity of your air conditioner. Always disconnect the power supply before performing any maintenance.
Filter Cleaning:
The air filters should be cleaned regularly, typically every two weeks, or more frequently depending on usage and air quality.
- Open the front panel of the indoor unit.
- Remove the air filters.
- Clean the filters using a vacuum cleaner or wash them with lukewarm water and a mild detergent.
- Allow the filters to dry completely in a shaded area before reinserting them.
- Close the front panel.
Unit Cleaning:
- Wipe the indoor and outdoor units with a soft, dry cloth. For stubborn dirt, use a damp cloth with a mild detergent, then wipe dry.
- Do not use harsh chemicals, abrasive cleaners, or solvents.
- Ensure the outdoor unit's coils are free from debris (leaves, dirt) to maintain airflow.
Seasonal Checks:
Before the cooling or heating season, it is advisable to have a professional technician inspect the refrigerant levels, electrical connections, and overall system performance.
7. Troubleshooting
Before contacting customer support, please refer to the following common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply; Remote control batteries low; Circuit breaker tripped. | Check power connection; Replace batteries; Reset circuit breaker. |
| Insufficient cooling/heating | Dirty air filters; Blocked outdoor unit; Doors/windows open; Temperature setting incorrect. | Clean filters; Clear obstructions from outdoor unit; Close doors/windows; Adjust temperature setting. |
| Unusual noise | Loose parts; Fan obstruction; Unit not level. | Check for loose parts; Remove obstructions; Ensure unit is level. If noise persists, contact service. |
| Water leakage from indoor unit | Clogged drain pipe; Improper installation. | Clear drain pipe; Contact professional for inspection. |
If the problem persists after attempting these solutions, please contact qualified service personnel.
8. Technical Specifications
| Specification | Detail |
|---|---|
| Brand | CLIVET |
| Model Number | ILA1-Y70M / MLA1-Y70M |
| Cooling Capacity | 24000 British Thermal Units (BTU) / 2 Tons |
| Product Dimensions | 33.6 x 24.4 x 67.3 cm |
| Refrigerant Type | R32 |
| Special Feature | Inverter Compressor |
| Filter Type | High-density filter and Cold catalyst filter |
| Control Method | Remote, App, Voice |
| Form Factor | Mini-split |
| Country of Origin | Italy |
9. Warranty and Customer Support
Warranty Information:
The Clivet EZCOOL 70M air conditioner comes with a limited warranty. For specific terms and conditions, please refer to the warranty card included with your product or contact Clivet customer service. Keep your proof of purchase for warranty claims.
Customer Support:
For technical assistance, service requests, or inquiries regarding your Clivet air conditioner, please contact your authorized dealer or visit the official Clivet website for support contact information.
Official Website: www.clivet.com (Please check for your regional website)