Walfront MS-190

Walfront MS-190 Motor Wind Screw Alarm User Manual

Electronic Security System

Introduction

This user manual provides detailed instructions for the installation, operation, and maintenance of the Walfront MS-190 220V Red Continuous Sound 120DB Motor Wind Screw Alarm Electronic Security System. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

Product Overview

The Walfront MS-190 is a robust motor-driven alarm designed for various security and signaling applications. It produces a continuous, loud sound of 120dB, making it suitable for factories, construction sites, and road fault devices.

Walfront MS-190 Motor Wind Screw Alarm

Figure 1: Front view of the Walfront MS-190 Motor Wind Screw Alarm, showcasing its red casing and sound vents.

Specifications

AttributeValue
Model NumberMS-190
Working Voltage220V
Sound TypeContinuous Sound (Motor Wind Screw Type)
ColorRed
Electricity50mA
Voice Size120dB
Power25W
WeightApprox. 400g (14.1oz)
MaterialIron
Product Dimensions3.94 x 1.97 x 3.15 inches

The MS-190 alarm is designed for durability and stable performance, featuring high and low temperature resistance.

Package Contents

Upon opening the package, please verify that all components are present and undamaged:

Safety Information

To ensure safe operation and prevent damage to the device or injury to personnel, please observe the following safety precautions:

Setup and Installation

The MS-190 alarm features a fixed base installation for easy mounting. Follow these steps for proper setup:

  1. Choose a Location: Select a stable and secure mounting surface. Ensure the location allows for optimal sound propagation and is protected from direct impact or excessive vibration.
  2. Mount the Base: Use appropriate screws and anchors (not included) to securely fasten the alarm's fixed base to the chosen surface. The base allows for adjustment of the sound outlet (Tuyere) up and down.
  3. MS-190 alarm with fixed base installation

    Figure 2: The MS-190 alarm showing its fixed base installation, which allows for vertical adjustment of the sound outlet.

  4. Wiring: Connect the two wires from the alarm unit to your 220V power source. Ensure correct polarity if specified, though for AC devices like this, polarity is often not critical. It is recommended to use a circuit breaker or fuse for protection.
  5. Video 1: A demonstration of handling the MS-190 alarm, showing its components and how the wires are connected. This video illustrates the physical aspects of the alarm and its wiring points.

  6. Secure Connections: Double-check all electrical connections to ensure they are secure and insulated to prevent short circuits.
  7. Final Check: Before applying power, visually inspect the installation to confirm everything is correctly mounted and wired.
Rear view of MS-190 alarm showing wiring

Figure 3: Rear view of the MS-190 alarm, highlighting the wiring entry point and mounting bracket.

Operating Instructions

The Walfront MS-190 alarm is designed for straightforward operation:

  1. Power On: Once installed and wired correctly, apply 220V power to the alarm. The alarm will immediately begin to produce a continuous sound.
  2. Power Off: To stop the alarm, disconnect the 220V power supply.

The alarm is intended for applications requiring a continuous audible signal, such as emergency alerts, warning signals, or process completion indicators in industrial or commercial settings.

MS-190 alarm in an industrial setting

Figure 4: An illustration of the MS-190 alarm's potential application in an industrial environment, such as a factory or construction site.

Maintenance

The Walfront MS-190 alarm requires minimal maintenance to ensure long-term reliability:

Troubleshooting

If you encounter issues with your MS-190 alarm, refer to the following table for common problems and solutions:

ProblemPossible CauseSolution
Alarm does not soundNo power supplyCheck power connection, circuit breaker, and ensure 220V supply.
Alarm sounds weak or intermittentInsufficient voltage or loose wiringVerify 220V supply. Check all wiring connections for tightness and corrosion.
Unusual noise or vibrationLoose mounting or internal component issueEnsure the alarm is securely mounted. If the issue persists, contact customer support.

If the problem persists after attempting these solutions, please contact Walfront customer support for further assistance.

Warranty and Support

Walfront products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or replacement parts, please refer to the official Walfront website or contact their customer service department. Keep your purchase receipt as proof of purchase for warranty claims.

For direct support, you may visit the Walfront Store on Amazon.

Related Documents - MS-190

Preview Fluke 190 Series III ScopeMeter Test Tool Users Manual
Comprehensive users manual for the Fluke 190 Series III ScopeMeter Test Tools and MDA-550-III Motor Drive Analyzer, covering operation, features, measurements, and troubleshooting for industrial electrical and electronic systems.
Preview Fire-Lite MS-9600LS/MS-9600UDLS Series Addressable Fire Alarm Control Panel Manual
This manual provides comprehensive guidance on the installation, operation, and programming of the Fire-Lite MS-9600LS, MS-9600LSE, MS-9600UDLS, MS-9600UDLSE, and MS-9600LSC addressable fire alarm control panels. It covers system setup, device configuration, operational procedures, and essential safety information.
Preview Grundfos MS, MMS Submersible Motors: Installation and Operating Instructions
Comprehensive installation and operating instructions for Grundfos MS and MMS submersible motors, covering delivery, storage, general description, preparation, electrical connection, installation, maintenance, fault finding, and cable sizing.
Preview Integrated Wireless Mini Scoreboards User Guide - Colorado Time Systems
User guide for Colorado Time Systems Integrated Wireless Mini Scoreboards (2.4 GHz wireless) for team sports. Covers product overview, installation, operating instructions, battery replacement, and technical standards for models MS-0055 through MS-0080.
Preview Fluke 190 Series III ScopeMeter Test Tools: High-Performance Oscilloscopes for Industrial Environments
Explore the Fluke 190 Series III ScopeMeter Test Tools, rugged portable oscilloscopes designed for harsh industrial environments. Discover features like high-speed sampling, deep memory, Connect-and-View™ triggering, TrendPlot™ recorder, and FlukeView™ software for efficient troubleshooting and analysis.
Preview Radio Station 190 (Ra 190) Technical Manual - Part II
Detailed technical manual for the Radio Station 190 (Ra 190), covering construction, function, service, and technical data. This manual is intended for service personnel and provides in-depth information on the transmitter, receiver, and associated components.