AIRAM 4126207

AIRAM K2-142 GR Ceiling Lamp User Manual

Model: 4126207

1. Introduction

Thank you for choosing the AIRAM K2-142 GR Ceiling Lamp. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new lighting fixture. Please read this manual thoroughly before installation and retain it for future reference.

The K2-142 chandelier features a colored glass shade surrounding the classic WIR lamp by Tapio Wirkkala. The elegant WIR lamp's shape and light beautifully shine through the lampshade. The slender K2-142 chandelier is beautiful on its own, but multiple units can be used in various configurations to create a spectacular lighting group. The product includes a dimmable WIR-85 LED lamp, a lamp holder, a black metal ceiling rose, and a 3.1-meter cable. The lampshades are made of mouth-blown clear glass, each lampshade is handmade and unique.

2. Safety Information

Always follow basic safety precautions when installing or using electrical products to reduce the risk of fire, electric shock, and personal injury.

  • WARNING: To avoid electric shock, ensure power is turned off at the circuit breaker or fuse box before installation or servicing.
  • Installation must be performed by a qualified electrician in accordance with all local electrical codes.
  • Do not connect this fixture to an ungrounded electrical system.
  • Do not modify the fixture or its components.
  • Ensure the mounting surface can support the weight of the fixture.
  • Use only the specified bulb type and wattage. This fixture includes a dimmable WIR-85 LED lamp.
  • Keep flammable materials away from the lamp when in operation.
  • Do not look directly into the LED light source when illuminated.

3. Package Contents

Verify that all components are present and undamaged before beginning installation. If any parts are missing or damaged, do not attempt to install the fixture. Contact customer support for assistance.

  • K2-142 GR Lamp Shade (Mouth-blown clear glass)
  • WIR-85 Dimmable LED Lamp
  • Lamp Holder (E27 fitting)
  • Black Metal Ceiling Rose
  • 3.1-meter Electrical Cable
  • Mounting Hardware (screws, anchors, etc. - specifics may vary)
Components of the Airam K2-142 GR lamp, including the glass shade, bulb, and ceiling rose.

Image: Overview of the Airam K2-142 GR lamp components, showing the glass shade, the WIR-85 LED lamp, and the black metal ceiling rose with cable.

4. Setup and Installation

This section provides step-by-step instructions for installing your AIRAM K2-142 GR Ceiling Lamp. Professional installation is recommended.

  1. Prepare for Installation:
    • Turn off power at the main circuit breaker or fuse box.
    • Ensure the power is off by testing the circuit with a voltage tester.
    • Gather necessary tools: screwdriver, wire strippers, electrical tape, ladder, safety glasses.
  2. Mount the Ceiling Rose:
    • Attach the mounting bracket (if separate) to the junction box in the ceiling using the provided screws.
    • Connect the fixture's ground wire (usually green or bare copper) to the ground wire from the junction box.
    • Connect the fixture's live wire (usually black or brown) to the live wire from the junction box.
    • Connect the fixture's neutral wire (usually white or blue) to the neutral wire from the junction box.
    • Secure all wire connections with wire nuts and electrical tape.
    • Carefully tuck all wires into the junction box.
    • Attach the black metal ceiling rose to the mounting bracket, securing it with the provided screws.
  3. Assemble the Lamp:
    • Carefully unpackage the mouth-blown glass shade.
    • Screw the WIR-85 dimmable LED lamp into the E27 lamp holder.
    • Attach the glass shade to the lamp holder assembly according to the specific design (e.g., by screwing it on or securing with retaining rings).
  4. Final Check:
    • Ensure all connections are secure and the fixture is firmly mounted.
    • Restore power at the circuit breaker.
    • Test the lamp's functionality.
Airam K2-142 GR ceiling lamp hanging from the ceiling.

Image: The Airam K2-142 GR ceiling lamp installed and hanging, showcasing its design.

Technical drawing with dimensions of the Airam K2-142 GR ceiling lamp.

Image: Technical diagram illustrating the dimensions of the Airam K2-142 GR lamp, including total height, cable length, and shade diameter.

5. Operating Instructions

The AIRAM K2-142 GR Ceiling Lamp is designed for simple operation.

  • Turning On/Off: Operate the lamp using a standard wall switch connected to the fixture's circuit.
  • Dimming Function: The included WIR-85 LED lamp is dimmable. To utilize this feature, ensure your wall switch is compatible with LED dimmers. Follow the dimmer manufacturer's instructions for operation.
Airam K2-142 GR lamp illuminated, showing the light output.

Image: The Airam K2-142 GR lamp illuminated, demonstrating the light distribution and the appearance of the WIR-85 LED bulb through the glass shade.

6. Maintenance

Regular maintenance will help prolong the life and maintain the appearance of your AIRAM K2-142 GR Ceiling Lamp.

  • Cleaning:
    • Always turn off power and allow the lamp to cool before cleaning.
    • Wipe the glass shade and metal parts with a soft, dry, or slightly damp cloth.
    • Do not use abrasive cleaners, solvents, or polishes as they may damage the finish.
  • Bulb Replacement:
    • Ensure power is off and the bulb has cooled completely.
    • Carefully unscrew the old bulb from the E27 lamp holder.
    • Screw in a new E27 base LED bulb, ensuring it is dimmable if you wish to retain the dimming functionality.
    • Dispose of old bulbs according to local regulations.
  • Inspection: Periodically inspect the wiring and connections for any signs of wear or damage. If any issues are found, consult a qualified electrician.

7. Troubleshooting

If you encounter issues with your AIRAM K2-142 GR Ceiling Lamp, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Lamp does not light up.No power to the fixture.
Bulb is loose or faulty.
Incorrect wiring.
Check circuit breaker/fuse.
Ensure bulb is screwed in tightly; replace if necessary.
Consult a qualified electrician to check wiring.
Lamp flickers.Loose bulb.
Incompatible dimmer switch.
Faulty wiring.
Tighten bulb.
Ensure dimmer is compatible with LED bulbs.
Consult a qualified electrician.
Dimming not working.Non-dimmable bulb used.
Incompatible dimmer switch.
Ensure WIR-85 or other dimmable LED bulb is installed.
Verify dimmer switch is designed for LED dimming.
Glass shade appears cloudy or dirty.Dust or residue buildup.Clean with a soft, dry, or slightly damp cloth. Do not use harsh chemicals.

If the problem persists after attempting these solutions, please contact customer support or a qualified electrician.

8. Specifications

FeatureDetail
BrandAIRAM
Model Number4126207
ASINB07P15ZPH3
ColorGrey
MaterialGlass, Metal
Light Fixture FormChandelier (Pendant Lamp)
Room TypeLiving Room, Dining Room
Power SourceAC
Special FeaturesDimmable
Light Source TypeLED (WIR-85 included)
Lampshade MaterialGlass
Number of Light Sources1
Diameter195 Millimeters
Cable Length3.1 meters (approx.)
Mounting RequiredYes
Batteries RequiredNo

9. Warranty and Support

For warranty information or technical support, please refer to the product packaging or contact AIRAM customer service directly. Keep your purchase receipt as proof of purchase.

Note: Specific warranty terms and contact details may vary by region and purchase location.

© 2024 AIRAM. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.