1. Introduction
This manual provides essential information for the installation, operation, and maintenance of the Roger R20/310 Swing Gate Kit. This kit is designed to automate swing gates, enhancing convenience and security. Please read these instructions carefully before beginning any installation or operation to ensure proper function and safety.
2. Safety Information
WARNING: Improper installation or use can lead to serious injury or property damage. Always follow safety guidelines.
- Installation must be performed by qualified personnel in compliance with local electrical and safety regulations.
- Disconnect power before performing any maintenance or service.
- Keep hands, feet, and clothing clear of the gate and moving parts during operation.
- Do not allow children to play with or near the gate or its controls.
- Ensure all safety devices, such as photocells, are correctly installed and functioning.
- Regularly inspect the system for wear, damage, or misalignment.
3. Kit Contents
The Roger R20/310 Swing Gate Kit includes the following components:
2 x R20/300 Electromechanical Actuators: 230V AC irreversible short and fast actuators, suitable for swing gates up to 2.5 meters per leaf. Includes 1 microswitch limit switch and fixing plates.
1 x H70/200AC/BOX Control Unit: Central control unit for two 230V AC motors, featuring slowdown functions, housed in a plastic enclosure.
2 x E80/TX52R/2 Remote Controls: 433.92 MHz fixed code, 2-channel remote controls with copy function.
1 x H93/RX22A/I Radio Receiver: 2-channel radio receiver operating at 433.92 MHz, compatible with H70, B70, EDGE, and CTRL series control units.
1 x R90/F2ES Pair of Synchronized Outdoor Photocells: Safety devices to detect obstructions in the gate's path.
1 x R92/LED230 Flashing LED Light: 230V AC flashing light for visual indication of gate operation.
1 x R91/AN1/LR1 Antenna: Antenna for the R92 series flashing light, enhancing radio signal reception.
Actuator Fixing Plates: Plates for secure mounting of the actuators.- 1 x R99/C/001 "Automatic Opening" Sign: Warning sign for automatic gate operation.
4. Specifications
Technical specifications for the Roger R20/310 Swing Gate Kit components:

Image: Roger R20/300 Actuator dimensions and force graph.
| Parameter | Value |
|---|---|
| Line Power Supply | 230 V AC - 50 Hz |
| Motor Power Supply | 230 V AC |
| Rated Power | 200 W |
| Frequency of Use | 40 % |
| Thrust | 2500 N |
| Operating Temperature | -20 to +55 °C |
| Protection Degree | IP43 |
| Reducer Type | Irreversible |
| Maneuvering Speed | 1.66 cm/s |
| Opening Time (90°) | 19 s |
| Stroke | 320 mm |
| Motor Thermal Protection | 150 °C |
| Built-in Capacitor | 15 µF |
| Limit Switch | Microswitch on opening (optional on closing) |
| Max Product Dimensions (L x W x H) | 858.5 x 120 x 165 mm |
| Packaged Product Weight | 20.6 kg |
5. Setup and Installation
This section provides a general overview of the installation process. Refer to the detailed installation manual provided with the product for specific diagrams and step-by-step instructions.
5.1. Site Preparation
- Ensure the gate structure is sound and operates smoothly manually.
- Verify adequate space for actuator movement and gate swing.
- Plan cable routes for power and control wiring, ensuring they are protected from damage and moisture.
5.2. Actuator Installation
- Mount the fixing plates securely to the gate post and gate leaf according to the provided template.
- Attach the R20/300 actuators to the fixing plates, ensuring correct alignment and smooth operation throughout the gate's travel.
- Adjust the mechanical stops or limit switches for precise open and closed positions.
5.3. Control Unit and Wiring
- Mount the H70/200AC/BOX control unit in a protected, easily accessible location near the gate.
- Connect the 230V AC power supply to the control unit, ensuring proper grounding.
- Wire the two R20/300 actuators to the control unit as per the wiring diagram.
- Install the H93/RX22A/I radio receiver board into the designated slot on the control unit.
5.4. Safety Devices Installation
- Mount the R90/F2ES photocells at the recommended height and distance, ensuring they are perfectly aligned and free from obstructions.
- Wire the photocells to the control unit's safety input terminals.
5.5. Flashing Light and Antenna Installation
- Mount the R92/LED230 flashing light in a visible location.
- Connect the R91/AN1/LR1 antenna to the flashing light and wire the light to the control unit.
5.6. Initial Power-Up and Programming
- Apply power to the control unit.
- Follow the control unit's specific instructions for initial setup, motor learning, and programming the E80/TX52R/2 remote controls.
- Test all safety features and gate movements thoroughly before final use.
6. Operating Instructions
Once installed and programmed, the Roger R20/310 Swing Gate Kit is designed for simple operation.
6.1. Using the Remote Control
- Press the programmed button on your E80/TX52R/2 remote control to activate the gate.
- A single press typically initiates an open or close cycle. Another press during operation may stop the gate, and a third press will reverse its direction (depending on programming).
- Ensure a clear line of sight to the gate and that no obstructions are present before operating.
6.2. Manual Override
In case of power failure or system malfunction, the gate can be operated manually. Locate the manual release mechanism on each actuator (refer to the actuator's specific manual for details) and follow the instructions to disengage the motor, allowing the gate to be moved by hand.
7. Maintenance
Regular maintenance ensures the longevity and safe operation of your Roger R20/310 Swing Gate Kit.
- Monthly: Check the gate's mechanical components for wear, rust, or damage. Ensure hinges are lubricated and free-moving.
- Quarterly: Inspect all electrical connections for corrosion or loose wiring. Clean photocell lenses to ensure clear operation. Test the functionality of all safety devices.
- Annually: Have the system inspected by a qualified technician to check motor performance, control unit settings, and overall system integrity.
- Keep the area around the gate and actuators clear of debris, vegetation, and obstructions.
8. Troubleshooting
This section addresses common issues. For complex problems, contact a qualified technician.
- Gate does not respond to remote control:
- Check remote control battery.
- Ensure the radio receiver is correctly installed and powered.
- Verify the remote control is programmed correctly to the control unit.
- Gate opens but does not close, or vice versa:
- Check for obstructions in the gate's path, especially around the photocells. Clean photocell lenses.
- Inspect wiring to actuators and safety devices for damage.
- Verify limit switch settings.
- Gate operates intermittently or slowly:
- Check power supply voltage.
- Inspect mechanical components for excessive friction or damage.
- Ensure actuators are properly lubricated.
- Flashing light does not operate:
- Check power connection to the flashing light.
- Verify the bulb/LED is functional.
9. Warranty and Support
For warranty information, technical support, or service, please contact ROGER TECHNOLOGY directly or your authorized dealer. Keep your purchase receipt as proof of purchase.