Goodman HKSX05XC

Goodman HKSX05XC 5 kW Electric Heat Kit

Model: HKSX05XC | Brand: Goodman

Introduction

This manual provides essential information for the proper installation, operation, and maintenance of the Goodman HKSX05XC 5 kW 208/240 V 1 Phase Electric Heat Kit. This electric heat kit is designed for use with compatible Goodman air handlers to provide supplemental or primary heating. Please read all instructions thoroughly before proceeding with installation or operation.

Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer or service agency.

  • Always disconnect all power to the air handler and heat kit before performing any service or installation.
  • Ensure all wiring complies with national and local electrical codes.
  • This unit operates at high voltage. Exercise extreme caution.
  • Do not operate the unit without proper grounding.
  • Keep combustible materials away from the heat kit.

Setup and Installation

The Goodman HKSX05XC Electric Heat Kit is designed for internal installation within a compatible Goodman air handler. Installation requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician.

General Installation Steps (for Qualified Technicians):

  1. Power Disconnection: Ensure all electrical power to the air handler unit is completely disconnected at the main breaker. Verify with a voltage meter.
  2. Access Air Handler: Open the access panel of the compatible Goodman air handler where the heat kit will be installed.
  3. Mounting: Carefully slide the HKSX05XC heat kit into the designated slot within the air handler. Secure it according to the specific air handler's instructions.
  4. Electrical Connections: Connect the heat kit's wiring to the air handler's control board and power supply terminals as indicated in the wiring diagram provided with both the heat kit and the air handler. Ensure all connections are tight and secure.
  5. Grounding: Verify proper grounding of the heat kit and air handler.
  6. Close and Secure: Replace and secure all access panels on the air handler.
  7. Power Restoration and Test: Restore power to the air handler. Test the heat kit operation through the thermostat to ensure it functions correctly and safely.
Internal view of a Goodman indoor air handler unit, showing the blower, coils, and control board. This is where the electric heat kit would be installed.

Figure 1: Illustrative internal view of a Goodman indoor air handler unit. The HKSX05XC electric heat kit is installed within such a unit to provide heating.

Operating Instructions

The Goodman HKSX05XC Electric Heat Kit operates in conjunction with your air handler and thermostat. There are no direct user controls on the heat kit itself.

Basic Operation:

  1. Thermostat Setting: Set your thermostat to the 'Heat' mode.
  2. Temperature Adjustment: Adjust the desired temperature on your thermostat to a setting higher than the current room temperature.
  3. Automatic Activation: The heat kit will automatically activate when the thermostat calls for heat, providing supplemental or primary heating as needed.

Refer to your air handler and thermostat manuals for specific operating instructions and advanced features.

Maintenance

Regular maintenance is crucial for the efficient and safe operation of your HVAC system, including the electric heat kit. All maintenance should be performed by a qualified HVAC technician.

Recommended Maintenance (by Qualified Technician):

  • Annual Inspection: Have a qualified technician inspect the heat kit and air handler annually, preferably before the heating season.
  • Electrical Connections: Check all electrical connections for tightness and signs of wear or corrosion.
  • Heating Elements: Inspect heating elements for damage or excessive dust accumulation.
  • Air Filter: Ensure the air handler's filter is clean and replaced regularly as per the air handler's manual. A dirty filter can restrict airflow and reduce heating efficiency.
  • Airflow: Verify proper airflow through the air handler and heat kit.

Troubleshooting

If you experience issues with your heating system, consult this section for common problems and potential solutions. For complex issues, always contact a qualified HVAC technician.

ProblemPossible CauseRecommended Action
No Heat
  • Thermostat set incorrectly
  • Power supply interrupted
  • Blown fuse or tripped breaker
  • Faulty heating element or control
  • Check thermostat settings (Heat mode, desired temperature)
  • Verify power to the air handler at the breaker panel
  • Check for tripped circuit breakers or blown fuses
  • Contact a qualified HVAC technician for diagnosis and repair
Insufficient Heat
  • Dirty air filter
  • Restricted airflow
  • Undersized heat kit
  • Partial heating element failure
  • Check and replace air filter if dirty
  • Ensure vents are open and not blocked
  • Contact a qualified HVAC technician for system evaluation and repair
Unusual Noises or Odors
  • Loose components
  • Electrical issue
  • Dust burning off elements (initial use)
  • If persistent or strong, immediately turn off power and contact a qualified HVAC technician
  • A slight burning smell during initial operation is normal as dust burns off. If it persists, seek professional help.

Specifications

FeatureDetail
Model NumberHKSX05XC
ManufacturerGoodman
Heating Capacity5 kW (5000 watts)
Voltage208/240 V
Phase1 Phase
Power SourceCorded Electric
Item Weight15 pounds
Item Package Quantity1
Date First AvailableJanuary 25, 2019

Warranty Information

Goodman offers comprehensive warranty coverage for its products. For the HKSX05XC Electric Heat Kit, when registered, you may be eligible for:

  • A 10-year unit replacement limited warranty (for the main HVAC unit, if applicable).
  • A lifetime compressor limited warranty (for the main HVAC unit, if applicable).
  • A 10-year parts limited warranty that provides replacement part(s) for any part found to be defective due to workmanship or materials under normal use and maintenance.

To ensure you receive the full benefits of your warranty, it is essential to register your new Goodman unit. Please refer to the official Goodman website or your product documentation for detailed warranty terms, conditions, and registration procedures.

Support and Contact

For technical assistance, warranty claims, or professional service, please contact a qualified HVAC technician or your Goodman dealer. You can also visit the official Goodman website for additional resources and contact information.

Goodman Manufacturing Company, L.P.
Website: www.goodmanmfg.com

Related Documents - HKSX05XC

Preview Goodman CPLE Series 10 SEER Split System Heat Pump Product Specifications
Detailed product specifications for the Goodman CPLE Series 10 SEER Split System Heat Pump. This document includes comprehensive information on standard features, cabinet construction, air handler and coil compatibilities, available accessories, detailed specifications, electrical data, unit dimensions, and extensive cooling and heating performance ratings for models ranging from 1½ to 5 Ton.
Preview Goodman Light Commercial 3-6 Ton Belt Drive Pkg Heat Pumps Repair Parts Catalog
Comprehensive repair parts catalog for Goodman Light Commercial 3-6 Ton Belt Drive Packaged Heat Pumps (RP-633). Details components, part numbers, and model applicability for HVAC technicians, covering various assemblies like top panel, cabinet, condenser/evaporator coils, blower, and control box.
Preview Goodman & Amana R-410A Split System Service Instructions
Comprehensive service manual for Goodman and Amana R-410A split system heat pumps, condensing units, air handlers, and coils, detailing product identification, troubleshooting, and servicing procedures for HVAC technicians.
Preview Goodman GSZ13/SSZ14 Split System Heat Pumps R-410A Service Instructions
Service manual for Goodman GSZ13 and SSZ14 split system heat pumps using R-410A refrigerant. Includes detailed information on blowers, coils, accessories, safety, operation, and troubleshooting for HVAC professionals.
Preview Goodman SD Side Discharge Inverter System - Efficient & Quiet HVAC
Discover the Goodman SD Side Discharge Inverter System, offering superior energy efficiency, quiet operation, and flexible installation for optimal home comfort. Learn about its advanced features, heritage, and specifications.
Preview Goodman PHK Series 10 SEER Self-Contained Packaged Heat Pump Specifications
Detailed product specifications, features, dimensions, cooling and heating performance ratings, electrical data, and accessory information for the Goodman PHK Series 10 SEER Self-Contained Packaged Heat Pump.