Junkers Hydronext 5700 S

Junkers Hydronext 5700 S Natural Gas Water Heater 12L User Manual

Model: Hydronext 5700 S | Brand: Junkers

1. Introduction

Thank you for choosing the Junkers Hydronext 5700 S Natural Gas Water Heater. This appliance is designed to provide efficient and reliable hot water for your home. Featuring a compact design and thermostatic control, it ensures comfort and energy savings. Please read this manual carefully before installation, operation, or maintenance to ensure safe and optimal performance.

  • Capacity: 12 Liters per minute
  • Fuel Type: Natural Gas
  • Special Features: WiFi Connectivity, Compact Design
  • Material: Stainless Steel
  • Efficiency: High
  • Installation Type: Wall-mounted
  • Dimensions (H x W x D): 575 x 335 x 180 mm
  • Low NOx: Designed for reduced nitrogen oxide emissions.
  • Flue Gas Exhaust: Up to 12 meters.

2. Safety Instructions

Always observe the following safety precautions to reduce the risk of fire, electric shock, personal injury, or property damage.

  • Qualified Personnel: Installation and servicing must be performed by a qualified technician in accordance with local codes and regulations.
  • Gas Supply: Ensure the gas supply is turned off before any maintenance or service.
  • Ventilation: Ensure adequate ventilation in the installation area. Do not obstruct air vents.
  • Flammable Materials: Keep flammable liquids and materials away from the water heater.
  • Water Pressure: Do not exceed the maximum permissible water pressure.
  • Children: Keep children away from the appliance during operation.
  • Leak Detection: Regularly check for gas or water leaks. In case of a gas leak, immediately shut off the gas supply, ventilate the area, and contact a qualified technician.
  • Power Supply: Disconnect electrical power before performing any service.

3. Product Overview

The Junkers Hydronext 5700 S is a compact, wall-mounted natural gas water heater. It features a modern design with an intuitive digital display for easy temperature control and monitoring.

Junkers Hydronext 5700 S water heater with flue pipe

Figure 3.1: Front view of the Junkers Hydronext 5700 S water heater with its associated flue pipe components. This image illustrates the compact design and the connection point for the exhaust system.

Junkers Hydronext 5700 S digital display

Figure 3.2: Close-up of the Junkers Hydronext 5700 S digital control panel. The display shows the current water temperature (e.g., 42°C) and includes touch controls for adjustment and settings.

Key Components:

  • Main Unit: The primary body housing the heat exchanger, burner, and control electronics.
  • Digital Display: Front-mounted interface for temperature setting and status indication.
  • Water Inlet/Outlet: Connections for cold water supply and hot water delivery.
  • Gas Inlet: Connection for the natural gas supply.
  • Flue Gas Outlet: Connection point for the exhaust system to safely vent combustion gases.
  • WiFi Module: Integrated for smart connectivity and remote control (if configured).

4. Setup and Installation

Installation of the Hydronext 5700 S must be carried out by a certified professional. Refer to the technical drawing and local regulations for proper installation.

Junkers Hydronext 5700 S technical drawing with dimensions and connections

Figure 4.1: Technical drawing illustrating the dimensions and connection points for the Junkers Hydronext 5700 S water heater. This diagram provides critical measurements for installation, including water and gas connections.

Installation Steps (Summary - Consult Professional):

  1. Location Selection: Choose a suitable wall-mounted location, ensuring adequate space for maintenance and ventilation.
  2. Mounting: Securely mount the appliance to the wall using appropriate fasteners, considering its weight (15 kg).
  3. Water Connections: Connect the cold water inlet and hot water outlet pipes. Ensure all connections are watertight.
  4. Gas Connection: Connect the natural gas supply line to the appliance. This step is critical and must be performed by a qualified gas technician.
  5. Flue System: Install the flue gas exhaust system, ensuring it meets the specified length (up to 12 meters) and is properly sealed to prevent gas leakage.
  6. Electrical Connection: Connect the appliance to the electrical supply as per local codes.
  7. Initial Startup: Follow the manufacturer's instructions for initial startup, including purging air from the system and checking for leaks.

Note: The maximum operating pressure is 500,000 Pascal. Ensure your water supply pressure is within acceptable limits.

5. Operating Instructions

The Hydronext 5700 S features user-friendly controls for setting your desired hot water temperature.

Basic Operation:

  1. Power On: Ensure the appliance is connected to the power supply and the gas valve is open.
  2. Temperature Adjustment: Use the controls on the digital display (refer to Figure 3.2) to set the desired water temperature. The thermostatic control will maintain this temperature.
  3. Hot Water Delivery: Open a hot water tap. The water heater will automatically ignite and begin heating water as it flows through the unit, up to a maximum flow rate of 12 liters per minute.
  4. WiFi Connectivity: If enabled, use the dedicated mobile application to monitor and control your water heater remotely. Refer to the separate WiFi setup guide for detailed instructions.

The appliance is designed for high efficiency, providing hot water on demand while minimizing energy consumption.

6. Maintenance

Regular maintenance ensures the longevity and efficient operation of your water heater. It is recommended that a qualified technician performs annual inspections and servicing.

User Maintenance (Monthly/Quarterly):

  • Visual Inspection: Check for any visible signs of leaks, corrosion, or damage to the unit and its connections.
  • Ventilation: Ensure that the area around the water heater is clear and that all ventilation openings are unobstructed.
  • Cleaning: Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners.

Professional Maintenance (Annually):

  • Burner and Heat Exchanger Cleaning: To ensure optimal efficiency and safety.
  • Flue System Inspection: Check for blockages, corrosion, and proper sealing.
  • Gas Pressure Check: Verify correct gas pressure settings.
  • Safety Device Check: Test all safety devices, including temperature and pressure relief valves.
  • Water Filter Cleaning: If applicable, clean or replace any inline water filters.

7. Troubleshooting

Before contacting customer support, please refer to the following common issues and their potential solutions.

Problem Possible Cause Solution
No hot water Gas supply off, power supply off, pilot light out (if applicable), water inlet valve closed. Check gas and power supply. Ensure water inlet valve is open. Consult a technician if pilot light is an issue.
Water not hot enough Temperature setting too low, insufficient gas flow, scale buildup. Increase temperature setting on the digital display. Contact a technician to check gas flow or descale the unit.
Error code on display Internal fault, sensor issue, or specific operational problem. Note the error code and consult the full service manual or contact a qualified technician.
Unusual noises Sediment buildup, loose components, or fan issues. Contact a qualified technician for inspection and repair.
Gas smell Gas leak. Immediately turn off the gas supply, ventilate the area, and contact emergency services and a qualified gas technician. Do not operate any electrical switches.

If the problem persists after attempting these solutions, or if you are unsure, always contact a qualified service technician.

8. Technical Specifications

Detailed technical information for the Junkers Hydronext 5700 S water heater.

Feature Value
Model Number Hydronext 5700 S (WTD124AMEN)
Brand Junkers
Manufacturer ROBERT BOSCH
Product Dimensions (L x W x H) 33.5 x 33.5 x 57.5 cm (15 kilograms)
Capacity 12 Liters
Power Source Natural Gas
Special Feature WiFi Connectivity, Compact Design
Color White
Material Stainless Steel
Maximum Flow Rate 12 Liters per minute
Efficiency High (Energy efficiency class A)
Style Compact
Installation Type Wall-mounted
Maximum Pressure 500,000 Pascal
Item Depth Greater than or equal to 335 millimeters

9. Warranty and Support

For warranty information, please refer to the documentation provided with your purchase or contact Junkers customer service. The manufacturer, ROBERT BOSCH, stands behind the quality of this product.

If you require technical assistance, spare parts, or service, please contact your local Junkers dealer or authorized service center. When contacting support, please have your model number (Hydronext 5700 S) and serial number ready.

Online Resources: Visit the official Junkers website for additional product information, FAQs, and support resources.

© 2024 Junkers. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.