Walfront Walfrontztcx8gqs0y

User Manual: HT-86 Temperature Humidity Meter

Model: HT-86 | Brand: Walfront

Introduction

The Walfront HT-86 Temperature Humidity Meter is a portable, digital instrument designed for accurate measurement of temperature and humidity. This device is suitable for a wide range of applications, including industrial, agricultural, meteorological, and daily life environments. This manual provides detailed instructions on the setup, operation, and maintenance of your HT-86 meter to ensure optimal performance and longevity.

Product Overview and Key Features

The HT-86 meter offers a combination of precision and user-friendly features:

Walfront HT-86 Temperature Humidity Meter

Figure 1: Front view of the Walfront HT-86 Temperature Humidity Meter, showing the display and control buttons.

Hand holding HT-86 meter highlighting professional quality and fast response time

Figure 2: The HT-86 meter held in hand, illustrating its professional quality with 0.01% RH and 0.01°C/F accuracy, and fast response time for quick measurements.

Labeled diagram of HT-86 meter components

Figure 3: Detailed diagram of the HT-86 meter, pointing out key components such as the double LCD display, data hold function, low battery warning, ergonomic design, automatic shutdown, fast response time, and maximum/minimum measurement capabilities.

Icons representing features of HT-86 meter

Figure 4: Visual representation of the meter's functions, including High Accuracy Sensor, Data Hold, C/F Conversion, Maximum/Minimum, Wet Bulb Temperature, Dew Point Temperature, Data Storage, LCD Screen, and Automatic Shutdown.

Setup

Battery Installation

The HT-86 Temperature Humidity Meter requires one 9-volt battery for operation. The battery compartment is located on the back of the device.

  1. Locate the battery cover on the back of the meter.
  2. Carefully slide or unclip the battery cover to open the compartment.
  3. Insert a new 9-volt battery, ensuring the polarity (+/-) matches the indicators inside the compartment.
  4. Replace the battery cover, ensuring it clicks securely into place.

Note: Always use a fresh 9-volt battery for optimal performance. The device may come with a battery pre-installed or included in the packaging.

Back view of HT-86 meter showing battery compartment warning

Figure 5: Rear view of the HT-86 meter, showing the battery compartment and a warning label indicating it uses a 9V battery (NEDA 1604 IEC 6F22).

Operating Instructions

Power On/Off

Press the power button (usually marked with a power symbol) to turn the device on. Press and hold the power button to turn it off. The meter features an automatic shutdown function to conserve battery life, which can also be disabled if needed.

Taking Measurements

Once powered on, the meter will immediately begin displaying current temperature and humidity readings. Allow a few seconds for the readings to stabilize, especially when moving the meter to a new environment.

Mode Button

Use the "MODE" button to cycle through different display modes, such as ambient temperature, dew-point temperature, and wet bulb temperature. Refer to the on-screen indicators to identify the current mode.

MAX/MIN Function

Press the "MAX/MIN" button to view the maximum and minimum recorded temperature and humidity values since the device was last reset or powered on. Press again to cycle through MAX, MIN, and current readings.

Data Hold Function

To freeze the current readings on the display, press the "HOLD" button. This is useful for recording values without needing to write them down immediately. Press the "HOLD" button again to release the data hold and resume live readings.

Temperature Unit Conversion (°C/°F)

The meter supports both Celsius (°C) and Fahrenheit (°F) temperature units. Consult the manual or device interface for specific instructions on how to switch between these units, typically via a dedicated button or a combination of button presses.

Maintenance

Cleaning

To clean the meter, wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the casing or display. Keep the sensor area clean and free from dust or debris for accurate readings.

Storage

When not in use for extended periods, remove the battery to prevent leakage and store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

Battery Replacement

Replace the 9-volt battery when the low battery indicator appears on the display. Follow the battery installation steps outlined in the "Setup" section.

Troubleshooting

Specifications

FeatureSpecification
Product Dimensions6.89 x 2.36 x 1.38 inches; 5.33 ounces (17.5cm x 5cm)
Model NumberWalfrontztcx8gqs0y (HT-86)
ManufacturerWalfront
Battery Type9 volts (NEDA 1604 IEC 6F22)
Mounting TypeTabletop
Upper Temperature Rating80 Degrees Celsius (176°F)
Wet Bulb Temperature Range0 to 80°C (32 to 176°F)
Dew-point Temperature Range-20 to 80°C (-4 to 176°F)
Humidity Resolution0.01% RH
Temperature Resolution0.01°C
HT-86 meter with dimensions 17.5cm by 5cm

Figure 6: Dimensions of the HT-86 meter, showing its height of 17.5cm (6.9in) and width of 5cm (2in).

Application

The Walfront HT-86 Temperature Humidity Meter is a versatile tool suitable for a variety of professional and daily applications where precise environmental monitoring is crucial. Its robust design and accurate sensors make it an ideal instrument for:

Collage of application scenarios for HT-86 meter

Figure 7: Examples of environments where the HT-86 meter can be effectively used, including greenhouses, residential spaces, medical facilities, laboratories, wine cellars, and industrial warehouses.