1. Introduction
The Pic Solution ClearRAPID is an advanced automatic arm-type blood pressure monitor designed for accurate and comfortable home use. It incorporates Rapid Tech - Comfort Experience technology, which measures blood pressure during cuff inflation, ensuring a quick and pleasant experience. The large, backlit display provides clear readings even in low light conditions. This device is equipped with features such as an irregular heartbeat detector, an arm movement sensor, and a real-time pressure level indicator. It also stores up to 200 readings for two users or morning/evening measurements and calculates the average of the last three readings, making it a valuable tool for consistent health monitoring.

Image: The Pic Solution ClearRAPID blood pressure monitor, its packaging, and the included carrying case.
2. Important Safety Information
Please read this manual thoroughly before using the device. Keep these instructions for future reference.
- This device is intended for non-invasive measurement and monitoring of arterial blood pressure in adults. It is not intended for use on infants or children.
- Do not use this device for diagnostic purposes. Always consult a healthcare professional for interpretation of blood pressure readings.
- Keep the device out of reach of children and pets.
- Do not disassemble or attempt to repair the device yourself. Refer all servicing to qualified personnel.
- Avoid using the device in environments with strong electromagnetic fields, such as near mobile phones or microwave ovens.
- Use only the specified cuff and accessories provided by the manufacturer.
3. Product Components
The Pic Solution ClearRAPID package includes the following items:
- 1 x Pic Solution ClearRAPID Automatic Arm-Type Blood Pressure Monitor Unit
- 1 x M-L Size Arm Cuff (22-42 cm)
- 1 x Carrying Case
- 4 x AAA Batteries (included)
- 1 x Instruction Manual

Image: The product packaging, showing the blood pressure monitor and its key features in English.
4. Setup
4.1 Battery Installation
1. Open the battery compartment cover located on the bottom of the device.
2. Insert four (4) AAA batteries, ensuring the correct polarity (+/-) as indicated inside the compartment.
3. Close the battery compartment cover securely.
4.2 Cuff Attachment
1. Connect the air tube of the cuff to the air jack on the side of the blood pressure monitor unit.
2. Ensure the cuff is suitable for your arm circumference (M-L size: 22-42 cm).
3. Wrap the cuff around your bare upper arm, approximately 2-3 cm (0.8-1.2 inches) above the elbow joint. The air tube should run down the inside of your arm.
4. The bottom edge of the cuff should be above the elbow. The artery mark on the cuff should be positioned over your brachial artery (on the inside of your arm).

Image: Detailed view of the blood pressure cuff, showing size indicators and proper arm placement.
5. Operating Instructions
5.1 Before Measurement
- Rest for at least 5 minutes before taking a measurement.
- Avoid eating, drinking alcohol, smoking, or exercising for 30 minutes prior to measurement.
- Sit comfortably with your back supported and feet flat on the floor. Do not cross your legs.
- Place your arm on a table so that the cuff is at heart level.
- Remain still and silent during the measurement.
5.2 Taking a Measurement
- Ensure the cuff is correctly attached to your arm and the air tube is connected to the monitor.
- Press the START/STOP button to turn on the device. The cuff will begin to inflate automatically.
- Remain still and do not talk during the inflation and measurement process. The Rapid Tech - Comfort Experience technology will measure during inflation.
- Once the measurement is complete, the cuff will deflate, and your systolic (SYS), diastolic (DIA), and pulse (Pul/min) readings will be displayed on the screen.
- Press the START/STOP button again to turn off the device, or it will automatically shut off after a period of inactivity.

Image: The blood pressure monitor's large digital display showing systolic, diastolic, and pulse readings.
5.3 Understanding Readings
- SYS (Systolic Pressure): The highest pressure in the arteries when the heart beats.
- DIA (Diastolic Pressure): The lowest pressure in the arteries when the heart rests between beats.
- Pul/min (Pulse Rate): The number of heartbeats per minute.
- Irregular Heartbeat Detector: If an irregular heartbeat is detected, a corresponding symbol will appear on the display. Consult your doctor if this symbol appears frequently.
- Arm Movement Sensor: An icon will appear if excessive arm movement is detected during measurement, indicating a potentially inaccurate reading.
5.4 Memory Function
The ClearRAPID monitor can store up to 200 readings, organized into two user areas (A and B), or for morning and evening measurements. It also automatically calculates the average of the last 3 readings.
- To access stored readings, press the MEM button.
- Use the SET button to switch between user areas (A/B) or to view different stored readings.
- The average of the last 3 readings will be displayed first when accessing the memory.

Image: A close-up view of the control buttons on the blood pressure monitor, including MEM, START/STOP, and SET.
6. Maintenance and Care
- Clean the device and cuff with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.
- Store the device in its carrying case in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity.
- Remove batteries if the device will not be used for an extended period to prevent battery leakage.
- Do not bend or crease the cuff's air tube excessively.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on. | Batteries are dead or incorrectly inserted. | Replace batteries or check polarity. |
| "Error" message on display. | Cuff not properly applied, excessive movement during measurement, or air leakage. | Re-apply cuff correctly, remain still, check cuff connection. Repeat measurement. |
| Inconsistent readings. | Improper measurement technique, external factors (stress, caffeine). | Ensure proper preparation and technique (see Section 5.1). Take multiple readings over time. |
| Cuff does not inflate. | Air tube disconnected or kinked. | Check air tube connection to the monitor and ensure it is not kinked. |
8. Technical Specifications
| Feature | Specification |
|---|---|
| Product Name | Blood Pressure Monitor |
| Brand | Pic Solution |
| Model Number | 02022526000000 |
| Manufacturer | Pikdare S.p.A. |
| Product Dimensions | 19.81 x 10.16 x 15.24 cm |
| Weight | 500 g |
| Power Source | 4 x AAA Batteries (included) |
| Cuff Size | M-L (22-42 cm) |
| Memory Capacity | 200 readings (2 users), average of last 3 readings |
| Measurement Method | Oscillometric |
9. Warranty and Support
The Pic Solution ClearRAPID Automatic Arm-Type Blood Pressure Monitor is guaranteed for a period of 5 years from the date of purchase against manufacturing defects.
For warranty claims, technical support, or any questions regarding the operation of your device, please contact the retailer where you purchased the product or refer to the contact information provided on the product packaging or the manufacturer's official website.