Pic Solution 02022526000000

Pic Solution ClearRAPID Automatic Arm-Type Blood Pressure Monitor User Manual

Model: 02022526000000

1. Introduction

The Pic Solution ClearRAPID is an advanced automatic arm-type blood pressure monitor designed for accurate and comfortable home use. It incorporates Rapid Tech - Comfort Experience technology, which measures blood pressure during cuff inflation, ensuring a quick and pleasant experience. The large, backlit display provides clear readings even in low light conditions. This device is equipped with features such as an irregular heartbeat detector, an arm movement sensor, and a real-time pressure level indicator. It also stores up to 200 readings for two users or morning/evening measurements and calculates the average of the last three readings, making it a valuable tool for consistent health monitoring.

Pic Solution ClearRAPID Blood Pressure Monitor with box and carrying case

Image: The Pic Solution ClearRAPID blood pressure monitor, its packaging, and the included carrying case.

2. Important Safety Information

Please read this manual thoroughly before using the device. Keep these instructions for future reference.

3. Product Components

The Pic Solution ClearRAPID package includes the following items:

Pic Solution ClearRAPID Blood Pressure Monitor box with English text

Image: The product packaging, showing the blood pressure monitor and its key features in English.

4. Setup

4.1 Battery Installation

1. Open the battery compartment cover located on the bottom of the device.
2. Insert four (4) AAA batteries, ensuring the correct polarity (+/-) as indicated inside the compartment.
3. Close the battery compartment cover securely.

4.2 Cuff Attachment

1. Connect the air tube of the cuff to the air jack on the side of the blood pressure monitor unit.
2. Ensure the cuff is suitable for your arm circumference (M-L size: 22-42 cm).
3. Wrap the cuff around your bare upper arm, approximately 2-3 cm (0.8-1.2 inches) above the elbow joint. The air tube should run down the inside of your arm.
4. The bottom edge of the cuff should be above the elbow. The artery mark on the cuff should be positioned over your brachial artery (on the inside of your arm).

Close-up of the blood pressure cuff with size and placement instructions

Image: Detailed view of the blood pressure cuff, showing size indicators and proper arm placement.

5. Operating Instructions

5.1 Before Measurement

5.2 Taking a Measurement

  1. Ensure the cuff is correctly attached to your arm and the air tube is connected to the monitor.
  2. Press the START/STOP button to turn on the device. The cuff will begin to inflate automatically.
  3. Remain still and do not talk during the inflation and measurement process. The Rapid Tech - Comfort Experience technology will measure during inflation.
  4. Once the measurement is complete, the cuff will deflate, and your systolic (SYS), diastolic (DIA), and pulse (Pul/min) readings will be displayed on the screen.
  5. Press the START/STOP button again to turn off the device, or it will automatically shut off after a period of inactivity.
Pic Solution ClearRAPID Blood Pressure Monitor display showing readings

Image: The blood pressure monitor's large digital display showing systolic, diastolic, and pulse readings.

5.3 Understanding Readings

5.4 Memory Function

The ClearRAPID monitor can store up to 200 readings, organized into two user areas (A and B), or for morning and evening measurements. It also automatically calculates the average of the last 3 readings.

Close-up of the Pic Solution ClearRAPID blood pressure monitor buttons

Image: A close-up view of the control buttons on the blood pressure monitor, including MEM, START/STOP, and SET.

6. Maintenance and Care

7. Troubleshooting

ProblemPossible CauseSolution
Device does not turn on.Batteries are dead or incorrectly inserted.Replace batteries or check polarity.
"Error" message on display.Cuff not properly applied, excessive movement during measurement, or air leakage.Re-apply cuff correctly, remain still, check cuff connection. Repeat measurement.
Inconsistent readings.Improper measurement technique, external factors (stress, caffeine).Ensure proper preparation and technique (see Section 5.1). Take multiple readings over time.
Cuff does not inflate.Air tube disconnected or kinked.Check air tube connection to the monitor and ensure it is not kinked.

8. Technical Specifications

FeatureSpecification
Product NameBlood Pressure Monitor
BrandPic Solution
Model Number02022526000000
ManufacturerPikdare S.p.A.
Product Dimensions19.81 x 10.16 x 15.24 cm
Weight500 g
Power Source4 x AAA Batteries (included)
Cuff SizeM-L (22-42 cm)
Memory Capacity200 readings (2 users), average of last 3 readings
Measurement MethodOscillometric

9. Warranty and Support

The Pic Solution ClearRAPID Automatic Arm-Type Blood Pressure Monitor is guaranteed for a period of 5 years from the date of purchase against manufacturing defects.

For warranty claims, technical support, or any questions regarding the operation of your device, please contact the retailer where you purchased the product or refer to the contact information provided on the product packaging or the manufacturer's official website.

Related Documents - 02022526000000

Preview Manuale d'uso: Kit Misurazione Glicemia Pic GlucoTest Diary
Guida completa per l'utilizzo del kit di misurazione della glicemia Pic GlucoTest e Pic GlucoTest Diary, con istruzioni dettagliate, impostazioni, manutenzione e risoluzione dei problemi.
Preview PiC Solution ThermoDiary EAR: Infrared Ear Thermometer User Manual
User manual for the PiC Solution ThermoDiary EAR infrared ear thermometer. Learn about its features, specifications, usage instructions, battery replacement, care, maintenance, and important warnings. This connected thermometer syncs with the PIC HEALTH STATION app.
Preview Fiche Technique Urinal PIC Solution - Spécifications et Conformité
Fiche technique détaillée pour l'urinal homme PIC Solution. Inclut les spécifications techniques, caractéristiques générales, indications d'utilisation, modalités de lavage, élimination, conformité et informations fabricant.
Preview Price Intelligent Controller (PIC) Engineering Guide
This engineering guide provides comprehensive details on the Price Intelligent Controller (PIC), a cutting-edge zone control package for building automation systems. It covers features, thermostat options, expansion modules, installation, setup, typical applications, networking, and technical specifications.
Preview Prodigy Digital VAV Diffusers Installation Manual
This manual provides comprehensive installation and operational guidance for the Price Prodigy Digital VAV Diffusers. It covers product overview, detailed installation procedures, power supply options, thermostat integration, BACnet networking, and troubleshooting.