1. Introduction
This manual provides detailed instructions for the proper installation, operation, and maintenance of the Red Lion Controls PAXP0000 Process Input Meter. Please read this manual thoroughly before attempting to install or operate the device to ensure safe and efficient use.
The PAXP0000 is a versatile process input meter designed for industrial applications, offering reliable measurement and display of various process parameters. Its field-upgradeable design allows for flexibility and adaptability to changing system requirements.
2. Safety Information
Always observe the following safety precautions to prevent personal injury and damage to the equipment:
- Ensure all power is disconnected before installation or maintenance.
- Installation and servicing should only be performed by qualified personnel.
- Do not operate the device in environments exceeding its specified operating conditions.
- Protect the device from moisture, dust, and extreme temperatures.
- Use only approved accessories and components.
3. Product Features
The Red Lion Controls PAXP0000 Process Input Meter offers a range of features designed for robust performance and ease of use:
- Process Input Capability: Designed to accept various process signals for measurement.
- Field Upgradeable: Allows for future enhancements and customization.
- Clear Digital Display: Provides easy-to-read measurement values.
- User-Friendly Interface: Intuitive buttons for configuration and operation.

Figure 1: Front panel of the Red Lion Controls PAXP0000 Process Input Meter. The display shows "67.4%" and five control buttons are visible: DSP (Display), PAR (Parameter), F1 (Function 1), F2 (Function 2), and RST (Reset).
4. Setup and Installation
Follow these steps for proper installation of your PAXP0000 meter:
- Mounting: Securely mount the meter in a suitable panel cutout according to the provided mounting dimensions (refer to product datasheet for exact dimensions).
- Wiring: Connect the process input signals, power supply, and any output connections to the appropriate terminals. Ensure all wiring conforms to local electrical codes and the device's specifications. Refer to the wiring diagram in the product datasheet.
- Power On: Once all connections are verified, apply power to the device. The display should illuminate.
- Initial Configuration: Access the parameter menu to configure input types, scaling, and desired display units.
5. Operating Instructions
The PAXP0000 features a user-friendly interface with dedicated buttons for operation and configuration:
- DSP (Display) Button: Used to cycle through various display modes or measured parameters.
- PAR (Parameter) Button: Used to enter the parameter configuration menu. Press and hold to access advanced settings.
- F1 (Function 1) Button: A programmable function button, typically used for specific actions or menu navigation.
- F2 (Function 2) Button: Another programmable function button, similar to F1, for additional actions or navigation.
- RST (Reset) Button: Used to reset certain functions, alarms, or values, depending on configuration.
Refer to the detailed programming guide for specific parameter settings and advanced operational modes.
6. Maintenance
The Red Lion Controls PAXP0000 is designed for minimal maintenance. Adhere to the following guidelines:
- Cleaning: Periodically clean the front panel with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Inspection: Regularly inspect wiring connections for tightness and signs of wear or corrosion.
- Calibration: Depending on the application and industry standards, periodic calibration may be required to ensure accuracy. Refer to your system's calibration procedures.
7. Troubleshooting
If you encounter issues with your PAXP0000 meter, consider the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank | No power, incorrect wiring, or internal fault. | Check power supply and wiring connections. Ensure correct voltage. If problem persists, contact technical support. |
| Incorrect readings | Incorrect input type configuration, scaling errors, or sensor issue. | Verify input type and scaling parameters in the configuration menu. Check sensor connections and functionality. |
| Buttons unresponsive | Temporary software glitch or physical damage. | Cycle power to the device. If buttons remain unresponsive, contact technical support. |
8. Specifications
Key specifications for the Red Lion Controls PAXP0000 Process Input Meter:
- Manufacturer: Red Lion Controls
- Model: PAXP0000
- ASIN: B07MZDG7P6
- Item Weight: 0.01 ounces (approximately 0.28 grams)
- Date First Available: January 21, 2019
- Input Type: Process Input (configurable)
- Upgradeability: Field Upgradeable
Note: For detailed electrical, environmental, and mechanical specifications, please refer to the official Red Lion Controls PAXP0000 datasheet.
9. Warranty Information
Red Lion Controls products are typically covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please refer to the official Red Lion Controls website or contact their customer service for detailed warranty information applicable to your purchase.
10. Technical Support
For technical assistance, troubleshooting beyond this manual, or inquiries regarding product functionality, please contact Red Lion Controls technical support. Support resources, including FAQs, documentation, and contact information, are usually available on the official Red Lion Controls website.
Website: www.redlion.net