Introduction
The Dukers D83R Commercial 3-Door Reach-in Refrigerator is designed for optimal performance in commercial settings. Featuring a 64.8 cu. ft. capacity, stainless steel interior and exterior, and digital temperature controls, this unit provides reliable refrigeration for various food service needs. This manual provides essential information for the safe and efficient operation and maintenance of your refrigerator.

Image: The Dukers D83R refrigerator with its three doors open, revealing a spacious interior with adjustable shelves holding various food products.
Safety Instructions
Read all instructions before using the appliance to reduce the risk of fire, electric shock, or injury. Keep this manual for future reference.
- Ensure the refrigerator is connected to a grounded power outlet (NEMA 5-20P).
- Do not operate the appliance with a damaged power cord or plug.
- Maintain adequate ventilation around the unit to prevent overheating.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Keep all ventilation openings clear of obstruction.
- Only qualified personnel should perform repairs or servicing.
Unpacking and Setup
What's in the Box
- Dukers D83R Commercial 3-Door Reach-in Refrigerator Unit
- 12 adjustable and removable wire shelves (4 for each door)
- 6 casters (wheels)
- 9 ft. power cord
Placement and Installation
1. Carefully remove all packaging materials. Inspect the unit for any shipping damage.
2. Install the provided casters. Ensure all casters are securely locked once the unit is in its final position to prevent movement.
3. Position the refrigerator on a level, stable surface capable of supporting its weight (approximately 595 lbs empty, plus contents).
4. Ensure there is sufficient clearance around the unit for proper ventilation. Avoid placing the unit near heat sources or in direct sunlight.
5. Connect the 9 ft. power cord to a dedicated 115V/60Hz, 8.6 Amps, 760 watts power outlet with a NEMA 5-20P plug. Do not use extension cords.

Image: A clear front view of the Dukers D83R refrigerator, highlighting its stainless steel construction and three distinct doors.
Operating Instructions
Initial Startup
After installation, allow the refrigerator to stand upright for at least 2 hours before plugging it in. Once plugged in, allow the unit to run empty for several hours (e.g., 4-6 hours) to reach its stable operating temperature before loading with products.
Temperature Control
The Dukers D83R features digital temperature controls with an LED display for precise adjustment. The temperature range is approximately 33°F to 41°F. Use the up and down arrows on the control panel to set the desired temperature. Press the 'SET' button to confirm your selection. The display will show the current internal temperature.
Shelving Adjustment
The refrigerator includes 12 adjustable and removable wire shelves, allowing for flexible storage configurations. To adjust a shelf, empty its contents, lift the shelf slightly, and reposition the shelf clips to the desired height. Ensure all clips are securely seated before placing items back on the shelf.

Image: The interior of the Dukers D83R refrigerator, showcasing the adjustable wire shelves and the bright internal lighting for clear visibility of contents.
Maintenance
Cleaning
Regular cleaning is essential for hygiene and optimal performance. Disconnect the power before cleaning.
- Interior: Wipe down the stainless steel interior and shelves with a mild detergent and warm water. Rinse thoroughly and dry completely to prevent water spots.
- Exterior: Clean the stainless steel exterior with a soft cloth and a non-abrasive stainless steel cleaner.
- Glass Doors: Use a glass cleaner for the glass panels.
- Condenser Coil: Periodically clean the condenser coil (located at the bottom) to ensure efficient cooling. Use a brush or vacuum cleaner to remove dust and debris.
Defrosting
The Dukers D83R features an automatic defrosting system, which helps maintain lower energy costs and consistent cold temperatures. Manual defrosting is generally not required under normal operating conditions.
Troubleshooting
If you experience issues with your refrigerator, consult the following general troubleshooting tips. For complex problems, contact a qualified service technician.
- Unit Not Cooling: Check if the power cord is securely plugged in. Verify the circuit breaker or fuse. Ensure the temperature setting is appropriate. Check for obstructions around the condenser coil.
- Excessive Noise: Ensure the unit is level. Check if any internal components or stored items are vibrating against each other.
- Water on Floor: Check the drain pan for overflow or blockage. Ensure the unit is level.
- Door Not Sealing Properly: Inspect door gaskets for damage or debris. Ensure shelves are not preventing the door from closing fully.
Technical Specifications
| Feature | Specification |
|---|---|
| Brand Name | Dukers |
| Model Info | D83R |
| Item Weight | 595 pounds |
| Product Dimensions (W x D x H) | 82.62 x 32.62 x 80.57 inches |
| Capacity | 64.8 Cubic Feet |
| Temperature Range | 33 to 41°F (approx.) |
| Voltage | 115 Volts |
| Wattage | 760 watts |
| Amperage | 8.6 Amps |
| Number of Doors | 3 |
| Shelves | 12 (adjustable wire) |
| Defrost System | Automatic |
| Material Type | Stainless Steel |
| Certifications | NSF/ANSI 7 Standard, ETL Listed / ETL Sanitation |
| Refrigerant | Natural R290 |
Warranty and Support
For warranty information, technical support, or service inquiries, please contact Dukers customer service directly. Keep your purchase receipt and model number (D83R) readily available when contacting support.