Aexit modle

Aexit Electric Cooker Thermostat Controller User Manual

Product Overview

This manual provides essential information for the installation, function, and maintenance of the Aexit Electric Cooker Thermostat Controller. This bimetal thermostat is designed as a reliable replacement part for electric cookers, ensuring precise temperature control and quick contact action.

Aexit Electric Cooker Thermostat Controller

Image: The Aexit Electric Cooker Thermostat Controller, showing its metal and ceramic construction with mounting points and electrical contacts.

Installation Guide

This thermostat controller is intended as a direct replacement part. Professional installation is recommended. Always ensure the electric cooker is unplugged and completely cool before attempting any installation or repair.

Safety Precautions:

  • Disconnect power to the electric cooker before beginning.
  • Wear appropriate personal protective equipment (PPE), such as gloves and eye protection.
  • If unsure about any step, consult a qualified electrician or appliance repair technician.

Installation Steps:

  1. Access the Thermostat: Carefully open the electric cooker's housing to locate the existing thermostat. This may involve removing screws or panels.
  2. Disconnect Old Thermostat: Note the wiring connections to the old thermostat. Take photos if necessary for reference. Carefully disconnect all wires and remove the old thermostat from its mounting.
  3. Mount New Thermostat: Position the Aexit Thermostat Controller in the same location as the old one. Secure it using the existing screw holes. The screw hole diameter is 4mm (0.16") and fix hole diameter is 2.5mm (0.098").
  4. Connect Wiring: Reconnect the wires to the new thermostat, ensuring they match the original configuration. This thermostat is rated for AC 250V 10A.
  5. Reassemble Cooker: Carefully reassemble the electric cooker's housing, ensuring all screws are tightened and panels are securely in place.
  6. Test Functionality: Plug the electric cooker back into a power outlet and test its operation to ensure the new thermostat is functioning correctly.

Functionality

The Aexit Thermostat Controller is a bimetal type, designed to regulate the temperature within your electric cooker. It operates by sensing the internal temperature and automatically opening or closing electrical contacts to control the heating element. This "heat compensate control" ensures a steady temperature and quick contact action, which is crucial for efficient and safe cooking.

Once installed, the thermostat operates automatically based on the cooker's design and temperature settings. No direct user interaction with the thermostat itself is required during normal operation of the electric cooker.

Maintenance

As a sealed electronic component, the Aexit Thermostat Controller requires minimal maintenance. However, to ensure its longevity and proper function within your electric cooker, consider the following:

  • Keep Dry: Ensure the area around the thermostat inside the cooker remains dry and free from moisture, which can damage electrical components.
  • Cleanliness: During routine cleaning of your electric cooker, ensure no liquids or debris enter the thermostat's housing.
  • Regular Inspection: If you open your cooker for other maintenance, visually inspect the thermostat for any signs of physical damage, corrosion, or loose connections.
  • Avoid Overheating: Always operate your electric cooker within its intended parameters to prevent excessive heat buildup that could stress the thermostat.

Troubleshooting

If your electric cooker is not functioning correctly after replacing the thermostat, consider the following common issues:

ProblemPossible CauseSolution
Cooker not heating at all.Incorrect wiring, faulty thermostat (rare for new part), or other cooker component failure.Double-check all wiring connections. Ensure power is supplied to the cooker. If problem persists, consult a professional.
Cooker overheating or not regulating temperature.Thermostat not properly installed or faulty.Verify thermostat is securely mounted and its sensing element is correctly positioned. If issue continues, the thermostat may be defective.
Intermittent heating.Loose connections or internal issue with the thermostat.Check all wire connections for tightness. If problem persists, replacement may be necessary.

Important: Always disconnect power before inspecting or attempting any repairs. If you are not comfortable performing these checks, seek assistance from a qualified appliance repair technician.

Product Specifications

FeatureDetail
Product NameThermostat Controller
Fit forElectric Cooker
Power RatingAC 250V 10A
Screw Hole Diameter4mm / 0.16"
Fix Hole Diameter2.5mm / 0.098"
Overall Size (L*W*T)3.5 x 3.5 x 3.8cm / 1.4" x 1.4" x 1.5"
MaterialMetal, Ceramic
Main ColorSilver Tone, White
Weight25g / 0.882 ounces
Voltage250 Volts
Model Numbermodle (f190413ae006163)

Warranty and Support

As a replacement part, specific warranty details may vary depending on the retailer and original purchase terms. Please refer to your purchase receipt or contact the seller directly for warranty information.

For technical support or further inquiries regarding the Aexit Thermostat Controller, please contact Aexit customer service or the retailer from whom the product was purchased. Always provide the product model number (modle) and any relevant purchase details when seeking support.

For general information about Aexit products, you may visit their official website if available, or search for "Aexit" online.

© 2023 Aexit. All rights reserved. This manual is for informational purposes only.