1. Introduction
This manual provides essential instructions for the safe and effective use of your Salter BPW-9101-EU Digital Wrist Blood Pressure Monitor. This device is designed for home use to measure systolic and diastolic blood pressure and pulse rate from the wrist. It also detects irregular heartbeats.
Regular monitoring of blood pressure can provide valuable insights into your health. Please read this manual thoroughly before first use and keep it for future reference.
2. Important Safety Information
- Consult your physician before using this device if you have any medical conditions.
- Do not use this device to diagnose or treat any health problem. Always consult a medical professional for diagnosis and treatment.
- Do not adjust medication based on measurements from this monitor without consulting your doctor.
- This device is intended for adult use only.
- Avoid taking measurements in a moving vehicle, during exercise, or immediately after bathing.
- Keep the device out of reach of children.
- Use only specified batteries. Do not mix old and new batteries.
3. Device Components

Image 1: Front view of the Salter BPW-9101-EU Digital Wrist Blood Pressure Monitor, showing the display, cuff, and control buttons.
- Display Screen: Shows blood pressure readings (systolic, diastolic), pulse rate, time, and memory indicators.
- Wrist Cuff: Adjustable cuff for placement on the wrist.
- MEM Button: Accesses stored measurement records.
- SET Button: Used for setting date/time and other parameters.
- Power Button (On/Off): Starts and stops measurements.
- WHO Classification Indicator: Color-coded bar on the left side of the display to indicate blood pressure classification (Severe, Moderate, Mild, High-normal, Normal, Optimal, Hypotension).
- Irregular Heartbeat Detector: Symbol on the display that appears if an irregular heartbeat is detected during measurement.
4. Setup
4.1 Battery Installation
- Open the battery compartment cover on the back of the device.
- Insert 2 AAA batteries, ensuring correct polarity (+ and -).
- Close the battery compartment cover securely.
4.2 Setting Date and Time
Accurate date and time settings are important for tracking your measurements.
- With the device off, press and hold the SET button for a few seconds until the year flashes.
- Press the MEM button to adjust the year. Press SET to confirm and move to the month.
- Repeat this process for month, day, hour, and minute.
- Once all settings are confirmed, the device will exit setup mode.
4.3 Applying the Wrist Cuff

Image 2: The Salter BPW-9101-EU monitor correctly positioned on a user's wrist, showing the display facing upwards.
The cuff is designed to fit wrist circumferences between 13.5 and 21.5 cm.
- Remove any tight clothing or accessories from your left wrist.
- Place the monitor on your left wrist with the display facing upwards, approximately 1-2 cm from your palm.
- Wrap the cuff snugly around your wrist. Ensure it is not too tight or too loose. The hook-and-loop fastener should be secure.
- Position your arm so the monitor is at heart level. You can support your elbow on a table and keep your palm open.

Image 3: Close-up view of the adjustable wrist cuff, highlighting its design for a secure and comfortable fit.
5. Operating Instructions
5.1 Taking a Measurement
- Sit comfortably with your back supported and feet flat on the floor. Relax for 5 minutes before taking a measurement.
- Ensure the cuff is correctly applied to your wrist and your arm is positioned at heart level.
- Press the Power button to start the measurement. The cuff will inflate automatically.
- Remain still and silent during the measurement.
- Once the measurement is complete, the systolic pressure, diastolic pressure, and pulse rate will be displayed.
- The result will be automatically stored in the device's memory.
- Press the Power button again to turn off the device, or it will automatically shut off after 1 minute of inactivity.
5.2 Interpreting Results

Image 4: The monitor's display illustrating the traffic light style WHO classification indicator and the irregular heartbeat detection symbol.
The monitor features a WHO (World Health Organization) classification indicator on the left side of the display. This color-coded bar helps you understand your blood pressure readings at a glance:
- Red (Sev.): Severe Hypertension
- Orange (Mod.): Moderate Hypertension
- Yellow (Mild): Mild Hypertension
- Light Green (High-norm.): High-Normal Blood Pressure
- Green (Norm.): Normal Blood Pressure
- Dark Green (Opt.): Optimal Blood Pressure
- Blue (Hype.): Hypotension (low blood pressure)
If the irregular heartbeat symbol appears on the display, it indicates that an irregular pulse was detected during the measurement. This is not a diagnosis, but a suggestion to consult your doctor.
5.3 Viewing Memory Records
The device can store up to 60 measurement records.
- With the device off, press the MEM button.
- The most recent measurement will be displayed first.
- Press the MEM button repeatedly to scroll through older records.
- To exit memory mode, press the Power button or wait for automatic shut-off.
6. Maintenance
6.1 Cleaning
- Clean the device and cuff with a soft, dry cloth.
- Do not use abrasive cleaners or immerse the device in water.
6.2 Storage
- Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- If the device will not be used for an extended period, remove the batteries to prevent leakage.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Batteries are dead or incorrectly inserted. | Replace batteries or check polarity. |
| Error message on display. | Cuff not applied correctly, movement during measurement, or other technical issue. | Re-apply cuff, remain still, or consult the full error code list in the comprehensive manual (if available). |
| Inconsistent readings. | Improper cuff placement, movement, talking, or incorrect body posture. | Ensure correct cuff placement, remain still and silent, and maintain proper posture. Take multiple readings at different times. |
If problems persist, contact Salter customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | BPW-9101-EU |
| Measurement Method | Oscillometric |
| Measurement Location | Wrist |
| Wrist Circumference | 13.5 - 21.5 cm |
| Memory Capacity | 60 records |
| Power Source | 2 x AAA batteries (included) |
| Display Type | Large LCD |
| Irregular Heartbeat Detection | Yes |
| WHO Classification Indicator | Yes |
| Product Dimensions (L x W x H) | 8.5 x 7 x 6.5 cm (approx.) |
| Product Weight | 140 grams (approx.) |
| Country of Origin | CN |
9. Warranty and Support
Salter products are manufactured to high standards. For warranty information, please refer to the warranty card included with your purchase or visit the official Salter website. For technical support or inquiries, please contact Salter customer service through their official channels.