1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of the ASCON D7-5055-0000 DIN Rail Mounting RS485 Transmitter. This device is designed for universal input and analogue retransmission, operating on 24VAC/DC power. Please read this manual thoroughly before using the product to ensure safe and efficient operation.
2. Safety Information
Always adhere to the following safety precautions to prevent injury or damage to the device:
- Ensure power is disconnected before installation or maintenance.
- Installation should only be performed by qualified personnel.
- Do not expose the device to excessive moisture, dust, or extreme temperatures.
- Verify correct wiring connections as per the wiring diagrams.
- Use appropriate personal protective equipment (PPE) during installation.
3. Product Features
The ASCON D7-5055-0000 transmitter offers the following key features:
- Universal Input: Compatible with various sensor types (e.g., thermocouples, RTDs, voltage, current).
- RS485 Communication: Enables digital data transmission and remote configuration.
- Analogue Retransmission: Provides a configurable analogue output (e.g., 4-20mA, 0-10V).
- DIN Rail Mounting: Easy integration into industrial control panels.
- 24VAC/DC Power Supply: Flexible power input for industrial environments.
- LED Indicators: Status LEDs for power, communication, and alarm conditions.
4. Package Contents
Upon unpacking, verify that all items are present and undamaged:
- 1 x ASCON D7-5055-0000 DIN Rail RS485 Transmitter
- 1 x User Manual (this document)
- (Optional) Mounting Screws or Clips (if applicable)
If any items are missing or damaged, contact your supplier immediately.
5. Setup and Installation
5.1. Physical Installation
The D7-5055-0000 is designed for DIN rail mounting. Follow these steps:
- Ensure the DIN rail is securely mounted within the control panel.
- Align the transmitter's DIN rail clip with the rail.
- Press firmly until the device clicks into place.
- Ensure adequate ventilation around the device to prevent overheating.
5.2. Wiring Connections
Refer to the image below for terminal identification. All wiring should comply with local electrical codes and standards.

Figure 1: Front view of the ASCON D7-5055-0000 transmitter. The image displays the device's front panel, featuring two sets of screw terminals (numbered 1-8 and 9-16), LED indicators (OP1, OP2, AL3, PWR, COM, ADDRESS), and the ASCON logo. The top terminals (1-8) and bottom terminals (9-16) are clearly visible, along with the D7 and RS485 symbols.
Terminal Assignments (Refer to Figure 1):
| Terminal No. | Description |
|---|---|
| 1-4 | Universal Input (e.g., Thermocouple, RTD, Voltage, Current) |
| 5-8 | Analogue Output (e.g., 4-20mA, 0-10V) |
| 9-12 | RS485 Communication (A, B, GND) |
| 13-16 | Power Supply (24VAC/DC) |
Wiring Steps:
- Connect the universal input sensor to terminals 1-4 according to the sensor's specifications.
- Connect the analogue output to your receiving device (PLC, DCS, etc.) using terminals 5-8.
- Connect the RS485 communication lines to terminals 9-12, ensuring correct polarity (A, B, GND).
- Connect the 24VAC/DC power supply to terminals 13-16. Observe polarity for DC power.
- Double-check all connections before applying power.
6. Operating Instructions
6.1. Power On and Initial Check
Once all wiring is complete and verified:
- Apply 24VAC/DC power to the device.
- Observe the PWR LED indicator. It should illuminate, indicating proper power supply.
- Check other LEDs (OP1, OP2, AL3, COM) for their status. Refer to the device's specific LED behavior for normal operation.
6.2. Configuration (via RS485)
The D7-5055-0000 is typically configured via its RS485 interface using a dedicated software tool provided by ASCON or a compatible Modbus RTU master. This allows for:
- Input type selection and range setting.
- Analogue output scaling and range.
- RS485 communication parameters (baud rate, parity, device address).
- Alarm setpoints and hysteresis.
- Calibration adjustments.
Refer to the ASCON configuration software manual for detailed instructions on parameter setup.
7. Maintenance
The ASCON D7-5055-0000 is designed for minimal maintenance. However, periodic checks are recommended:
- Visual Inspection: Regularly inspect the device for any signs of physical damage, loose connections, or corrosion.
- Cleaning: If necessary, gently clean the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Connection Integrity: Periodically check that all terminal connections are secure.
- Calibration Check: Depending on the application and required accuracy, periodic re-calibration of the input and output may be necessary. Refer to the configuration software manual for calibration procedures.
Note: There are no user-serviceable parts inside the unit. Do not attempt to open the enclosure.
8. Troubleshooting
This section provides guidance for common issues. For problems not listed here, contact ASCON technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| No Power (PWR LED off) | No power supply; incorrect voltage; faulty wiring. | Check power source, verify voltage (24VAC/DC), inspect wiring connections. |
| Incorrect Analogue Output | Incorrect input scaling; faulty sensor; wiring error; output load issue. | Verify input configuration in software; check sensor functionality; inspect output wiring; ensure load impedance is within specifications. |
| RS485 Communication Failure | Incorrect baud rate/parity; wrong device address; wiring polarity reversed; bus termination issues. | Check communication settings in software; verify device address; ensure A/B wiring is correct; check bus termination resistors. |
| Input Reading Inaccurate | Sensor issue; incorrect input type selected; calibration required. | Verify sensor operation; confirm input type and range in configuration; perform calibration if necessary. |
9. Specifications
Key technical specifications for the ASCON D7-5055-0000:
| Parameter | Value |
|---|---|
| Model | D7-5055-0000 |
| Input Type | Universal (Thermocouple, RTD, Voltage, Current) |
| Output Type | Analogue Retransmission (e.g., 4-20mA, 0-10V configurable) |
| Communication | RS485 (Modbus RTU) |
| Power Supply | 24VAC/DC |
| Mounting | DIN Rail |
| Operating Temperature | -10°C to +60°C (typical) |
| Dimensions | Standard DIN rail module size (refer to datasheet for exact dimensions) |
| Manufacturer | ASCON |
| Minimum Frequency | 50 Hz (for AC power) |
10. Warranty and Support
ASCON products are manufactured to high quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official ASCON website. Keep your purchase receipt as proof of purchase.
For technical assistance, troubleshooting beyond this manual, or spare parts inquiries, please contact ASCON technical support or your local distributor. When contacting support, please have your product model number (D7-5055-0000) and serial number (if applicable) ready.
ASCON Official Website: www.ascon.it (Note: This is a placeholder URL, please refer to official documentation for the correct support contact information.)