Sonew Sonewd4gcansgbh

Sonew RFID Touch Metal Access Control Keypad Machine Controller User Manual

Model: Sonewd4gcansgbh | Brand: Sonew

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Sonew RFID Touch Metal Access Control Keypad Machine Controller. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Product Overview

The Sonew RFID Touch Metal Access Control Keypad is a professional system designed for secure access management in homes, offices, factories, and communities. It supports multiple unlocking methods including RFID key card, password, or a combination of both.

2.1. Key Features

2.2. Package Contents

3. Specifications

FeatureDetail
MaterialPVC
Working VoltageDC 12V
Identification WaySmart Card
Inductive WayID Card + Password
Card Reading Distance2-10cm
Storage Capacity1000 Users
Unlock TypeID Card / Password / ID Card + Password
SizeApprox. 11.8 * 7.6 * 2.1cm (4.6 * 3.0 * 0.8in)
Item Weight4.9 ounces
ColorSilver

4. Setup and Installation

Proper installation is crucial for the optimal performance and security of your access control system. Follow these steps carefully.

4.1. Component Identification

Familiarize yourself with the main components of the access control keypad.

Sonew RFID Touch Metal Access Control Keypad front view

Figure 1: Front view of the Sonew RFID Touch Metal Access Control Keypad, showing the numeric keypad and bell button.

Sonew RFID Touch Metal Access Control Keypad with dimensions

Figure 2: Side view of the keypad illustrating its dimensions (11.8cm/4.6inch height, 7.6cm/3.0inch width).

Back of Sonew RFID Touch Metal Access Control Keypad showing wiring terminals

Figure 3: Rear view of the keypad, revealing the wiring terminals and product information label.

Wiring harness for Sonew RFID Touch Metal Access Control Keypad

Figure 4: Included wiring harness with color-coded wires for connection to the access control system.

4.2. Wiring Diagram and Connections

Refer to the following video for a detailed demonstration of the wiring process for the access control keypad, power supply, and electric lock.

Video 1: Wiring of Wiegand Access Control System. This video demonstrates how to connect the RFID reader, power supply, electric lock (fail-safe and fail-secure), and exit button to the access control panel.

Ensure all connections are secure and follow local electrical codes. Incorrect wiring can damage the device or pose a safety risk.

5. Operating Instructions

This section covers the basic operations of your access control keypad, including adding users and unlocking methods.

5.1. Default Admin Code

The default factory master code is 999999. This code is required to enter programming mode for adding or deleting users.

5.2. Adding Keyfobs (RFID Cards)

To add new RFID keyfobs for user access:

  1. Ensure the keypad is in standby mode (red light is always on).
  2. Press * to enter admin mode. The red light will flash.
  3. Enter the default admin code (999999) followed by # to confirm. The green light will illuminate, indicating successful entry into admin mode.
  4. Press 1 to enter the add user mode.
  5. Present the new keyfob to the keypad. The keypad will beep to confirm the addition. You can add multiple keyfobs consecutively.
  6. Press * twice to exit programming mode.

Video 2: S601ID Add Keyfobs, Add User Code Operation. This video demonstrates the process of adding keyfobs and user codes to the access control system.

Video 3: How to add users with Retekess T-AC03? This video provides a general guide on adding users to an access control keypad, which can be applied to this model.

5.3. Adding User Codes (Passwords)

To add new user passwords for access:

  1. Ensure the keypad is in standby mode (red light is always on).
  2. Press * to enter admin mode. The red light will flash.
  3. Enter the default admin code (999999) followed by # to confirm. The green light will illuminate.
  4. Press 1 to enter the add user mode.
  5. Input a unique user number (e.g., 79) followed by #.
  6. Input a 4-digit user code (e.g., 2468) followed by # to confirm.
  7. Press * twice to exit programming mode.

Video 4: K1201, K1202 Add User Code Operation. This video demonstrates the procedure for adding user codes to the access control keypad.

Video 5: K10 Keypad Add User Code. Another demonstration of adding user codes, providing additional visual guidance.

5.4. Unlocking the Door

To unlock the door using the keypad:

Sonew RFID Touch Metal Access Control Keypad showing multiple access methods

Figure 5: The keypad supports various access methods: card, password, or a combination of both.

Sonew RFID Touch Metal Access Control Keypad with password input highlighted

Figure 6: The keypad allows for 3-6 digit password entry for door access.

5.5. Tuya App Integration (If Applicable)

If your model supports Tuya App integration, follow these steps to connect and manage your access control system remotely.

Video 6: How to connect Tuya App. This video guides you through the process of connecting your access control keypad to the Tuya smart home application for remote management and unlocking.

6. Maintenance

To ensure the longevity and reliable operation of your access control keypad, follow these maintenance guidelines:

7. Troubleshooting

If you encounter issues with your access control keypad, refer to the following common problems and solutions:

8. Warranty and Support

For any product-related issues, please contact Sonew customer support. We are committed to providing timely assistance and solutions.