1. Introduction
This manual provides detailed instructions for the safe installation, operation, and maintenance of the Leviton T5015-T 15 Amp, 125 Volt, Narrow Body Single Receptacle. This commercial-grade, tamper-resistant device is designed for reliable performance in various electrical applications. It features impact-resistant thermoplastic construction, back-wire and side-wire terminal options, a heavy-gauge zinc-plated steel wraparound strap, a brass staked self-grounding clip, and heavy-duty triple-wipe brass contacts for extended service life.
2. Safety Information
WARNING: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. Installation should be performed by a qualified electrician in accordance with all national and local electrical codes.
- Always disconnect power before working on electrical circuits.
- Use appropriate personal protective equipment (PPE).
- Ensure all wire connections are secure and properly insulated.
- Do not exceed the specified electrical ratings of the device.
- This device is for indoor use only.
3. Package Contents
- Leviton T5015-T 15 Amp 125 Volt Tamper-Resistant Receptacle
- Mounting Screws (typically pre-installed or included)
4. Installation Instructions
Follow these steps carefully to install your Leviton T5015-T receptacle.
- Turn Off Power: Locate the circuit breaker or fuse that supplies power to the outlet box where you will install the receptacle. Turn it OFF. Verify power is off using a voltage tester.
- Remove Old Receptacle (if applicable): Unscrew the wallplate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the old receptacle out of the box. Disconnect the wires.
- Prepare Wires: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure the wire ends are clean and straight.
- Identify Wires:
- Hot/Live Wire: Typically black or red. Connects to the brass-colored terminal screws.
- Neutral Wire: Typically white. Connects to the silver-colored terminal screws.
- Ground Wire: Typically green or bare copper. Connects to the green hexagonal ground screw.
- Wire the Receptacle: The Leviton T5015-T offers both back-wire and side-wire terminal options.

Image: Front view of the Leviton T5015-T 15 Amp 125 Volt Tamper-Resistant Receptacle. It shows the light almond colored body, the two tamper-resistant slots, the grounding hole, and the metal mounting straps with screws. A green grounding screw is visible on the side.
Side Wiring:- Form a hook at the end of each wire.
- Connect the hot wire(s) to the brass terminal screws.
- Connect the neutral wire(s) to the silver terminal screws.
- Connect the ground wire to the green hexagonal ground screw.
- Tighten all terminal screws firmly.
- Insert the stripped end of the hot wire(s) into the back-wire holes adjacent to the brass terminal screws.
- Insert the stripped end of the neutral wire(s) into the back-wire holes adjacent to the silver terminal screws.
- Connect the ground wire to the green hexagonal ground screw using the side-wire method.
- Tighten all terminal screws firmly to secure the back-wired connections.
- Mount the Receptacle: Carefully fold the wires into the electrical box, leaving enough room for the receptacle. Secure the receptacle to the electrical box using the provided mounting screws.
- Install Wallplate: Attach the wallplate (not included) over the receptacle.
- Restore Power: Turn the power back ON at the circuit breaker or fuse box. Test the receptacle with a known working device.
5. Operation
The Leviton T5015-T is a standard 15 Amp, 125 Volt single receptacle. Its tamper-resistant (TR) feature includes internal shutters that prevent the insertion of single objects into the slots, enhancing safety, especially in homes with children. To operate, simply insert a standard two- or three-prong plug into the receptacle openings. The shutters will open only when a two- or three-prong plug is inserted simultaneously into both slots.
6. Maintenance
- Cleaning: Clean the receptacle face with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Inspection: Periodically inspect the receptacle for any signs of damage, discoloration, or loose connections. If any issues are found, disconnect power and consult a qualified electrician.
7. Troubleshooting
- No Power:
- Check the circuit breaker or fuse for the circuit. Reset if tripped or replace if blown.
- Verify all wire connections are secure within the electrical box.
- Plug Does Not Insert:
- Ensure you are inserting a two- or three-prong plug straight and simultaneously into both slots. The tamper-resistant shutters require simultaneous pressure.
- Inspect the plug for bent prongs.
- Receptacle is Hot to Touch:
- Immediately disconnect power. This indicates a potential overload or faulty wiring. Consult a qualified electrician.
8. Specifications
| Feature | Specification |
|---|---|
| Manufacturer | Leviton |
| Model Number | T5015-T |
| Amperage | 15 Amps |
| Voltage | 125 Volts |
| Material | Thermoplastic (Body) |
| Color | Light Almond |
| Item Weight | 1.6 ounces |
| Certifications | CSA, UL |
| Wiring Options | Back-wire and Side-wire |
| Feature | Tamper-Resistant, Grounding |
9. Warranty and Support
This Leviton T5015-T receptacle is covered by a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or visit the official Leviton website. For technical support or further assistance, please contact Leviton customer service.
Leviton Official Website: www.leviton.com