Zerone B07K6FWC17

Zerone Logo

Zerone Automatic Pump Control Pressure Switch Controller 110V User Manual

Model: B07K6FWC17

1. Product Overview

The Zerone Automatic Pump Control Pressure Switch Controller is designed to automate the operation of various water pumps. It replaces traditional pump control systems, offering functions such as automatic pump start/stop, water level monitoring, and dry-run protection. This controller is suitable for well pumps, jet pumps, garden pumps, clarified water pumps, and centrifugal pumps.

Zerone Automatic Pump Control Pressure Switch Controller

Figure 1: Zerone Automatic Pump Control Pressure Switch Controller

2. Key Features

3. Installation and Setup

Proper installation is crucial for the safe and efficient operation of the pump controller. If you are unsure about any steps, consult a qualified professional.

3.1 Components Overview

Angled view of the pump controller

Figure 2: Angled view of the controller showing inlet and outlet ports.

3.2 Mounting

Mount the controller vertically on a wall or stable surface using appropriate fasteners. Ensure it is protected from direct sunlight, rain, and freezing temperatures. The unit should be installed above the highest water level of the pump to prevent water ingress into the electrical components.

3.3 Plumbing Connections

  1. Connect the pump's discharge pipe to the controller's inlet port (typically marked 'IN' or with an arrow indicating flow into the unit).
  2. Connect the household water supply pipe to the controller's outlet port (typically marked 'OUT' or with an arrow indicating flow out of the unit).
  3. Ensure all connections are watertight using thread sealant tape or appropriate gaskets.
Various installation examples of the pump controller

Figure 3: Examples of pump controller installations with various pump types.

3.4 Electrical Connections

This device operates on 110V AC. All electrical wiring should be performed by a qualified electrician in accordance with local codes and regulations.

  1. Ensure the main power supply is disconnected before making any electrical connections.
  2. Connect the power supply cable (110V AC) to the designated input terminals on the controller.
  3. Connect the pump's power cable to the designated output terminals on the controller.
  4. Secure all wiring connections and ensure proper grounding.
More examples of pump controller installations

Figure 4: Additional installation scenarios for the pump controller.

4. Operation

Once properly installed and powered, the Zerone Automatic Pump Control operates automatically.

4.1 Initial Start-up

  1. Open a tap in your water system to allow water to flow.
  2. Restore power to the controller. The 'Power on' indicator should illuminate.
  3. The pump will start automatically. Allow it to run until water flows steadily from the open tap, indicating the system is primed.
  4. Close the tap. The pump should continue to run for a few seconds to build pressure, then stop. The 'Pump on' indicator will turn off.

4.2 Automatic Function

The controller monitors water pressure and flow. When a tap is opened, the pressure drops, and the controller starts the pump. When the tap is closed, the pressure rises, and the controller stops the pump after a short delay.

4.3 Dry-Run Protection and Restart

If the pump runs without water (dry-run), the 'Failure' indicator will illuminate, and the pump will stop to prevent damage. To restart the pump after a dry-run event:

  1. Ensure the water supply to the pump is restored.
  2. Press the Restart button on the controller. The pump will attempt to restart.
  3. If the water supply is still insufficient, the 'Failure' indicator will re-illuminate, and the pump will stop again. Repeat the process once water supply is confirmed.

Video 1: Demonstration of the 110V Automatic Pump Control Pressure Switch Electronic. This video shows the physical unit and its indicator lights.

Video 2: Overview of the Automatic Pump Control Pressure Switch. This video highlights the features and design of the unit.

5. Maintenance

The Zerone Automatic Pump Control is designed for minimal maintenance. However, regular checks can ensure longevity and optimal performance.

6. Troubleshooting

Refer to the following table for common issues and their solutions.

ProblemPossible CauseSolution
Pump does not start when tap is opened.No power; 'Failure' indicator on; pump motor issue.Check power supply. If 'Failure' is on, press Restart button after ensuring water supply. Check pump motor for issues.
Pump runs continuously.Leak in plumbing system; check valve issue; controller malfunction.Inspect plumbing for leaks. Check if the pump's check valve is functioning correctly. If issues persist, consult support.
'Failure' indicator is on.Dry-run (no water supply); air in the system.Ensure water supply is available. Press the Restart button. Prime the pump if necessary to remove air.
Pump cycles on and off rapidly.Small leak in the system; pressure fluctuations.Check for minor leaks. Ensure stable water pressure from the source.

7. Specifications

Dimensions of the Zerone Automatic Pump Control Pressure Switch Controller

Figure 5: Product dimensions.

AttributeValue
Operation ModeAutomatic
Current Rating10 Amps
Operating Voltage110 Volts (AC)
Frequency50/60 Hz
Max Pump Power1.1 KW
Max Working Pressure10 Bar (1 MPa)
Contact TypeNormally Open
Connector TypePipe Fitting (for Water), Hardwired (for Electrical)
MaterialMetal, Plastic
Item Dimensions (L x W x H)9.45 x 0.67 x 6.69 inches
Item Weight2.67 pounds
Mounting TypeWall Mount
Compatible DevicesSelf-priming pumps, Jet pumps, Garden pumps, Clarified water pumps, Centrifugal pumps

8. Warranty and Support

For warranty information or technical support, please contact Zerone customer service. Keep your purchase receipt and product model number (B07K6FWC17) handy for faster service.