The BT-1800 is a non-contact infrared thermometer designed for measuring extremely high temperatures in industrial applications such as metal melting furnaces, forges, kilns, and ceramic firing. It features a wide temperature range, high distance-to-spot ratio, and adjustable emissivity for accurate measurements.

Safety Information

  • Laser Safety: This device uses a Class 2 laser product (Wavelength 630-670 nm, Output <0.5mW). Do not stare directly into the laser beam. Avoid directing the laser beam at eyes or reflective surfaces.
  • Intended Use: This thermometer is designed for measuring the temperature of inanimate objects only. It is not accurate for measuring human or animal body temperature and should not be used for medical purposes.
  • Handling: Handle the device with care. Avoid dropping or subjecting it to strong impacts.
  • Environment: Do not expose the device to extreme temperatures, humidity, or corrosive environments.
  • Cleaning: Refer to the Maintenance section for proper cleaning instructions.

Product Overview

The BTMETER BT-1800 is a handheld infrared thermometer featuring a robust design and advanced measurement capabilities. Key components are illustrated below:

BTMETER BT-1800 Infrared Thermometer with labeled parts
Figure 1: BTMETER BT-1800 Infrared Thermometer with labeled components including LCD screen, mode button, laser button, trigger, backlight/flashlight button, unit conversion buttons, and battery door.
  • LCD Screen: Displays temperature readings, mode indicators, and settings.
  • MODE Button: Used to cycle through measurement modes (MAX/AVG/MIN/DIF/LAL/HAL), select emissivity, and set high/low temperature alarms.
  • Laser Pointer Button: Toggles the laser pointer on/off.
  • Trigger: Activates measurement and laser.
  • Backlit Screen/Flashlight Button: Toggles screen backlight and the integrated flashlight.
  • °C/DN Button: Changes temperature unit to Celsius and navigates down in menus.
  • °F/UP Button: Changes temperature unit to Fahrenheit and navigates up in menus.
  • Battery Door: Provides access for battery installation.
BTMETER BT-1800 Infrared Thermometer front view
Figure 2: Front view of the BTMETER BT-1800 Infrared Thermometer, showing the laser hole and infrared lens.

The device also features a metal screw hole for tripod mounting and a D-shape buckle for attachment to belt loops, enhancing portability and stability during use.

BTMETER BT-1800 Infrared Thermometer showing tripod mount and D-shape buckle
Figure 3: The BT-1800 with its tripod mounting screw hole and D-shape buckle for secure carrying. Note: Tripod is not included.

Setup

Battery Installation

The BT-1800 requires a 9V battery for operation. Follow these steps to install or replace the battery:

  1. Locate the battery compartment on the handle of the thermometer.
  2. Open the battery door.
  3. Connect the 9V battery to the battery connector, ensuring correct polarity.
  4. Place the battery into the compartment and close the battery door securely.
Video 1: Demonstrates the process of removing and inserting the 9V battery into the BTMETER BT-1800 Infrared Thermometer. This video also shows how to attach the carabiner to the device's base.

Attaching the Carabiner

For convenient carrying, you can attach the provided carabiner to the base of the thermometer:

  1. Locate the small screw at the bottom of the handle.
  2. Use a small screwdriver to remove this screw.
  3. Insert the carabiner's loop into the hole and secure it by re-inserting and tightening the screw.

Operating Instructions

Video 2: Provides a general overview of the BTMETER BT-1800 Industrial Pyrometer, demonstrating its features and basic operation, including temperature measurement and mode changes.

Basic Temperature Measurement

  1. Point the thermometer at the target object.
  2. Press and hold the Trigger to begin measurement. The laser pointer will activate to indicate the measurement area.
  3. The temperature reading will be displayed on the LCD screen. Release the trigger to hold the reading.
BTMETER BT-1800 Infrared Thermometer measuring temperature of molten metal
Figure 4: The BT-1800 in use, demonstrating non-contact temperature measurement of a high-temperature object.
Examples of temperature readings on the BTMETER BT-1800 for a hot object and a cold object
Figure 5: Examples of temperature readings displayed on the BT-1800, showing measurements for both high (1989°F) and low (44.9°F) temperatures.

Unit Conversion (°F/°C)

To switch between Celsius (°C) and Fahrenheit (°F), press the °C/DN or °F/UP button while the device is on.

Mode Selection and Emissivity Adjustment

Press the MODE button to cycle through various functions:

  • MAX: Displays the maximum temperature recorded during a scan.
  • MIN: Displays the minimum temperature recorded during a scan.
  • AVG: Displays the average temperature recorded during a scan.
  • DIF: Displays the difference between the maximum and minimum temperatures.
  • LAL (Low Alarm): Set a low temperature alarm. The device will flash if the measured temperature falls below this value.
  • HAL (High Alarm): Set a high temperature alarm. The device will flash if the measured temperature exceeds this value.
  • Emissivity (E): Adjust the emissivity setting (0.1 to 1.0) to match the surface being measured for improved accuracy. Consult a reference table for common material emissivities.

To adjust values (e.g., alarm thresholds or emissivity), use the °F/UP and °C/DN buttons after selecting the desired mode with the MODE button.

Laser Pointer and Flashlight

  • Press the Laser Pointer Button to turn the laser on or off. The BT-1800 features dual laser pointers for precise targeting.
  • Press the Backlit Screen/Flashlight Button to activate the screen backlight or the integrated flashlight for use in dark environments.
BTMETER BT-1800 Infrared Thermometer showing dual laser pointers
Figure 6: The BT-1800 features dual laser pointers to accurately define the measurement area.

Distance to Spot Ratio (D:S)

The BT-1800 has a Distance to Spot (D:S) ratio of 50:1. This means that at a distance of 50 units from the target, the measurement spot diameter will be 1 unit. A higher D:S ratio allows for accurate temperature measurement from a greater distance, which is crucial for high-temperature applications.

Diagram illustrating the 50:1 Distance to Spot Ratio of the BTMETER BT-1800
Figure 7: Illustration of the 50:1 Distance to Spot Ratio, showing how the measurement spot size increases with distance.

Auto Power Off

The device features an automatic power-off function to conserve battery life. It will power off after a period of inactivity.

Maintenance

  • Cleaning: To clean the device, wipe it with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the lens is clean for accurate readings.
  • Battery Replacement: Replace the 9V battery when the low power indicator appears on the display. Refer to the "Battery Installation" section for instructions.
  • Storage: Store the thermometer in a cool, dry place when not in use.

Troubleshooting

ProblemPossible CauseSolution
Inaccurate Temperature Readings
  • Incorrect emissivity setting for the target material.
  • Target object does not fill the measurement spot.
  • Infrared lens is dirty or obstructed.
  • Measuring highly reflective surfaces directly.
  • Adjust the emissivity setting (E) to match the surface being measured.
  • Move closer to the target or ensure the target is larger than the measurement spot.
  • Clean the infrared lens with a soft, dry cloth.
  • For reflective surfaces, apply a non-reflective matte paint or tape to the measurement area and measure its temperature after it stabilizes.
Device Does Not Power On
  • Battery is dead or improperly installed.
  • Replace the 9V battery with a fresh one.
  • Ensure the battery is correctly connected to the terminals and the battery door is securely closed.
Screen Not Displaying Correctly / Blank Screen
  • Device malfunction or internal error.
  • Attempt to remove and reinsert the battery.
  • If the issue persists, contact customer support for assistance or warranty claim.

Specifications

FeatureDetail
BrandBTMETER
Model NameBT-1800
Special FeatureNon-Contact
ColorBT-1800 Blue (-58°F ~3272°F)
Included ComponentsIndustrial Thermometer
Outer MaterialPlastic
Specification MetCE, FCC
Display TypeDigital
Connectivity TechnologyInfrared
Product Care InstructionsWipe Clean
Power SourceBattery Powered (9V)
Temperature Range-58°F ~ 3272°F (-50°C ~ 1800°C)
Accuracy
  • +/- 3% +3 digits for -58 to 320°F
  • +/- 2% +2 digits for 32 to 2120°F
  • +/- 3% +3 digits for 2120 to 3272°F
Response Time0.25 seconds
Repeatability1% of reading or 1°C
Distance to Spot Ratio (D:S)50:1
EmissivityAdjustable 0.1 to 1.0
Laser TypeClass 2, Wavelength 630-670 nm, Output <0.5mW
Item Weight0.44 Pounds
Indoor/Outdoor UsageOutdoor
ReusabilityReusable

Warranty and Support

The BTMETER BT-1800 Infrared Thermometer comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For warranty claims, technical support, or any inquiries, please contact BTMETER customer service.

Manufacturer: BTMETER

For additional resources and product information, you may visit the BTMETER Store.

Related Documents - BT-1800

Preview BTMETER BT-1500 Quick Start Guide
A quick start guide for the BTMETER BT-1500 infrared thermometer, covering battery installation, basic operation, and display interpretation.
Preview BTMETER BT-1500 Non-Contact Infrared Thermometer User Manual
User manual for the BTMETER BT-1500 non-contact infrared thermometer, covering its introduction, how it works, safety warnings, quick start guide, maintenance procedures, and detailed specifications.
Preview User Manual for BTMETER Phone Thermal Camera
Comprehensive user manual for the BTMETER Phone Thermal Camera. Learn how to use the thermal imaging app, adjust settings, measure temperatures, and maintain your device.
Preview User Manual: BTMETER Dual Vision Thermal Camera
Comprehensive user guide for the BTMETER Dual Vision Thermal Camera, covering installation, app interface, temperature measurement features, and safety precautions.
Preview BTMETER BT-570CAPP Bluetooth Connection Guide
Step-by-step instructions for connecting the BTMETER BT-570CAPP clamp meter to your smartphone via Bluetooth.
Preview BTMETER BT-770M Digital Multimeter Operator's Manual - Specifications and Operation
Comprehensive operator's manual for the BTMETER BT-770M digital multimeter, detailing specifications, testing procedures, safety information, and maintenance for accurate electrical measurements.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.