TUXING TXED011

TUXING 4500Psi Double Cylinder PCP Air Compressor (Model TXED011) User Manual

Brand: TUXING | Model: TXED011

1. Introduction

This manual provides essential instructions for the safe and efficient operation, setup, maintenance, and troubleshooting of your TUXING TXED011 4500Psi Double Cylinder PCP Air Compressor. Please read this manual thoroughly before using the compressor to ensure proper function and to prevent injury or damage.

The TUXING TXED011 is a high-pressure air compressor designed for filling PCP air rifles, paintball tanks, and other high-pressure air equipment. It features a double-cylinder, two-stage compression system with both water and fan cooling for stable performance and efficient heat dissipation.

TUXING TXED011 4500Psi Double Cylinder PCP Air Compressor

Front view of the TUXING TXED011 air compressor, showcasing its robust frame and dual cylinder design.

2. Safety Information

WARNING: Failure to follow these safety instructions may result in serious injury or property damage.

  • Always inspect the outer packaging and the machine for any damage upon receipt.
  • The compressor temperature must not exceed 85°C (185°F). Continuous running time should not exceed 45 minutes. Allow the unit to cool down between cycles.
  • Before operation, ensure the breathing rod is installed and the oil cap is replaced. Add oil to the level of the red dot on the dipstick.
  • When connecting the filter and hose, verify that the blue filter and hose are correctly assembled and there are no leaks.
  • Due to transportation restrictions, silicone oil is not included. Users must prepare silicone oil separately for lubrication.
  • The filling pressure must not exceed 300 Bar / 4500 PSI / 30 MPa.
  • Never operate the machine without a properly set up external water cooling system. Ensure cooling water is prepared in an external bucket before starting.
  • Keep hands and loose clothing away from moving parts.
  • Operate in a well-ventilated area.
  • Do not modify the compressor in any way.

3. Setup

3.1 Unpacking and Initial Inspection

Carefully remove the compressor from its packaging. Check all components against the packing list. Inspect the unit for any visible damage that may have occurred during shipping.

3.2 Adding Lubricating Oil

  • Locate the oil filler cap and the breathing rod.
  • Remove the oil filler cap and insert the breathing rod.
  • Add appropriate silicone oil (not included) until the oil level reaches the red dot on the dipstick.
  • Ensure the breathing rod is securely in place before operation.

3.3 Setting Up the Cooling System

The TXED011 requires an external water cooling system to operate safely. Prepare a bucket of clean water (approximately 10-15 liters) and connect the compressor's water inlet and outlet hoses to the bucket. Ensure the water pump is submerged and functioning correctly to circulate water through the compressor.

TUXING TXED011 compressor with fan cooling system

Side view of the compressor showing the integrated fan cooling system for efficient heat dissipation. This unit also requires an external water cooling system.

3.4 Connecting the Filling Hose and Filter

  • Connect the filling hose to the compressor's output port.
  • Ensure the inline filter (blue filter) is properly assembled with the filling hose to maintain air quality.
  • Connect the other end of the filling hose to the tank or device you intend to fill.
  • Verify all connections are tight and leak-free.

3.5 Power Connection

Connect the compressor to a standard 110V, 60Hz power outlet. Ensure the power source can handle the 2.2kW power requirement of the compressor.

4. Operating Instructions

4.1 Pre-Operation Checks

  • Confirm oil level is correct.
  • Verify water cooling system is active and circulating water.
  • Ensure all hose connections are secure.
  • Check that the tank to be filled is rated for the desired pressure and is securely connected.

4.2 Starting the Compressor

  • Turn on the power switch. The compressor will begin to operate.
  • Monitor the pressure gauge and the digital thermometer.

4.3 Filling Procedure and Monitoring

The compressor features a manual shut-off for precise control. Continuously monitor the pressure gauge. Once the desired pressure is reached (do not exceed 300 Bar / 4500 PSI), manually switch off the compressor.

Double cylinder head of TUXING TXED011 compressor with water cooling design and fill times

Close-up of the compressor's double cylinder head, highlighting the water cooling design and approximate fill times for 0.5L and 6.8L tanks.

Approximate Fill Times:

  • 0.5L tank from 0 to 300 Bar (4500 PSI): Approximately 3 minutes.
  • 6.8L tank from 0 to 300 Bar (4500 PSI): Approximately 45 minutes.

During operation, ensure the compressor's temperature remains below 85°C. If the temperature approaches this limit, stop the compressor and allow it to cool down before resuming.

4.4 Shutting Down

  • Once filling is complete, turn off the compressor's power switch.
  • Slowly release any residual pressure in the hose before disconnecting.
  • Disconnect the filling hose from the tank.

5. Maintenance

5.1 Oil Level and Replacement

Regularly check the oil level before each use. Replace the silicone oil periodically, or if it appears discolored or contaminated. Refer to the red dot on the dipstick for the correct oil level.

5.2 Filter Replacement

The inline filter (blue filter) and filter cotton are crucial for maintaining air quality. Replace the filter cotton regularly, especially if you notice reduced airflow or moisture in the output air. Spare filter cotton is typically included.

TUXING TXED011 compressor details including 2200W motor, oil water filter, filter cotton, 8mm quick connector

Detailed view of the compressor's 2200W motor and included accessories like the oil-water filter, filter cotton, and 8mm quick connector.

5.3 Cooling System Maintenance

Keep the external water bucket clean and ensure the water pump is free from debris. Periodically flush the water cooling system to prevent buildup. Ensure the fan cooling system is clear of obstructions.

5.4 General Cleaning

Keep the exterior of the compressor clean and free of dust and dirt. Use a dry cloth for cleaning. Do not use harsh chemicals or abrasive cleaners.

6. Troubleshooting

ProblemPossible CauseSolution
Compressor does not startNo power, faulty switch, motor issueCheck power connection, ensure switch is ON. If problem persists, contact support.
Low pressure outputLeaking connections, clogged filter, low oilCheck all connections for leaks, replace filter cotton, check and add oil.
Compressor overheatsInsufficient water cooling, prolonged operation, blocked fanEnsure water cooling is adequate, allow unit to cool, clear fan obstructions. Do not exceed 45 minutes continuous operation.
Excessive noiseLoose parts, worn componentsInspect for loose bolts or components. If noise is unusual, discontinue use and contact support.

7. Specifications

FeatureSpecification
BrandTUXING
Model NameTXED011
Voltage110 Volts (AC)
Power2.2 Kilowatts (2200W)
Frequency60Hz
Working Pressure30 MPa / 300 Bar / 4500 PSI
Flow Rate40 L/min (3.15 Cubic Meters Per Minute)
Cooling SystemWater-cooled & Fan-cooled
Noise Level85 Decibels
Item Weight31 Kilograms (68.2 pounds)
Product Dimensions20.47 x 15.75 x 18.9 inches
MaterialStainless Steel
Included ComponentsHose
Hose Length0.5 Meters
Batteries2 LR44 batteries required (included for digital thermometer)

8. Warranty and Support

The main parts of the TUXING TXED011 Air Compressor come with a 1-year warranty from the date of purchase. Please retain your proof of purchase for warranty claims.

For technical support, troubleshooting assistance, or warranty inquiries, please contact TUXING customer service. You can visit the official TUXING Store on Amazon for more information and contact options: TUXING Official Store.

9. Product Videos

No official product videos from the seller were available in the provided data to embed in this manual.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.