Rinnai EX17CTP

Rinnai EX17CTP Direct Vent Propane Gas Wall Furnace User Manual

Model: EX17CTP

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Rinnai EX17CTP Space Heater Wall Furnace.

1. Introduction

The Rinnai EX17CTP Direct Vent Wall Furnace is designed to provide efficient and consistent heating for indoor spaces. This unit features stainless steel bunsen burners, a warm air outlet with forced combustion and convection through bottom front louvers, and an enameled tray humidifier. It is suitable for homes, apartments, condominiums, and commercial settings, and is approved for modular/mobile home use.

Key features include an electronic spark ignition, a seven-stage modulating gas valve, timer settings, a variable speed inducer motor with pressure switch, and an electronic thermostat with a temperature range of 60°F to 80°F. For safety, it incorporates a child lock and self-diagnostic electronics that monitor functions, provide auto shutdown codes, and automatically restart if ignition or combustion fails.

Video: Rotational view of the Rinnai EX17CTP Wall Furnace, highlighting its exterior design and compact form factor.

Video: Overview of Rinnai's features and benefits, including energy efficiency and heating performance.

2. Setup and Installation

The Rinnai EX17CTP is designed for indoor installation only and requires direct venting. Professional installation by a qualified technician is highly recommended to ensure proper and safe operation, as well as compliance with local codes and regulations.

2.1 Unpacking and Inspection

Carefully unpack the unit and inspect it for any shipping damage. Report any damage immediately to your dealer or installer.

2.2 Location Requirements

  • Ensure the installation location allows for proper direct venting to the outside.
  • Maintain adequate clearances from combustible materials as specified in the installation manual.
  • The unit is wall-mounted; ensure the wall structure can support the unit's weight (57 lbs).
  • The unit requires a standard electrical outlet for its electronic spark ignition and fan operation.

2.3 Gas Connection

Connect the unit to a propane gas supply. All gas connections must be performed by a licensed professional.

2.4 Venting

The direct vent system draws combustion air from outside and exhausts combustion by-products outside, ensuring safe indoor air quality. Follow the detailed instructions in the separate installation manual for proper venting.

Rinnai EX17CTP Space Heater Wall Furnace

Image: Front view of the Rinnai EX17CTP Direct Vent Wall Furnace.

3. Operating Instructions

The Rinnai EX17CTP features a user-friendly control panel for easy operation.

3.1 Power On/Off

  • Press the On/Off button to turn the unit on or off.

3.2 Setting Temperature

  • Use the Temp Up/Down arrows to adjust the desired room temperature. The thermostat range is 60°F to 80°F.
  • The unit will automatically modulate its heat output to maintain the set temperature.

3.3 Timer Settings

  • The unit includes programmable timer settings (Timer 1, Timer 2) to schedule heating cycles. Refer to the detailed programming section in the full manual for specific instructions.

3.4 Child Lock

  • Activate the Lock function to prevent unintended changes to settings, especially useful in households with children.

3.5 Economy Mode

  • Engage Economy mode to optimize energy consumption. In this mode, the unit allows the temperature to drop by a few degrees before actively heating, reducing continuous operation.

4. Maintenance

Regular maintenance ensures the longevity and efficient operation of your Rinnai EX17CTP furnace.

4.1 Filter Cleaning

The unit is equipped with a mesh filter that collects dust and debris. A 'Filter' indicator light on the control panel will illuminate when cleaning is required.

  • Turn off the unit before attempting to clean the filter.
  • Locate the filter access panel, typically at the top or front of the unit.
  • Gently pull out the mesh filter.
  • Clean the filter by rinsing it with water or vacuuming off accumulated dust and lint. Ensure it is completely dry before reinserting.
  • Reinsert the filter and close the access panel. Turn the unit back on.
Rinnai EX17CTP with feature icons

Image: Diagram illustrating key features of the Rinnai EnergySaver Direct Vent Wall Furnace, including indoor installation, consistent heating, user-friendly control panel, wall thermostat compatibility, high altitude approval, modulating technology with convection fan, and warranty details.

4.2 Annual Inspection

It is recommended to have a qualified service technician inspect the unit annually to ensure all components are functioning correctly and safely.

5. Troubleshooting

The Rinnai EX17CTP features self-diagnostic electronics. If an issue occurs, the unit may display an error code or shut down automatically.

  • No Heat/Unit Not Turning On: Check the power supply and gas connection. Ensure the unit is switched on and the thermostat is set above the current room temperature.
  • Filter Light On: Clean the air filter as described in the Maintenance section.
  • Unusual Noises: While the unit is designed for quiet operation, any new or loud noises should be investigated. Ensure the fan is not obstructed.
  • Error Codes: If an error code appears on the display, consult the detailed troubleshooting guide in the full product manual or contact Rinnai customer support.

For persistent issues, contact a qualified service technician.

6. Specifications

FeatureSpecification
BrandRinnai
Model NumberEX17CTP
Fuel TypePropane
Heat Output17,000 British Thermal Units (BTU)
Heating Coverage340-354 square feet
Min Temperature Setting60°F
Max Temperature Setting80°F
Power SourceCorded Electric, Gas Powered
Form FactorWall-Mounted
Indoor/Outdoor UsageIndoor
Item Weight57 Pounds
UPC766156009860
Rinnai EX17CTP Product Dimensions and Specifications

Image: Detailed product specifications for the Rinnai EX17CTP, including depth, height, width, weight, gas type, installation type, power consumption, noise level, altitude approval, wall thermostat compatibility, and warranty.

Rinnai EnergySaver Direct Vent Wall Furnace Model Comparison

Image: Comparison table of various Rinnai EnergySaver Direct Vent Wall Furnace models (EX08CT, EX11CT, EX17CT, EX22CT, EX38CT), showing differences in gas type, fan CFM output, power consumption, noise level, and BTU range. The EX17CTP is highlighted.

National Heat Zones and Heating Area Size for Rinnai EX17CTP

Image: Map of National Heat Zones with a table indicating recommended cubic feet and square feet heating area for the EX17CTP model across different zones.

Comparison of Rinnai EX17CTP and EX17DTP models

Image: Side-by-side comparison of the Rinnai EX17CTP and EX17DTP models, detailing similarities in power consumption, length x width x height, and noise level, and differences in weight.

7. Warranty and Support

7.1 Warranty Information

Rinnai products are built to high standards. The EX17CTP typically includes a residential warranty:

  • Heat Exchanger: 10 Years
  • Labor: 2 Years
  • Parts: 5 Years

*Terms & Conditions may apply. Please refer to your product registration or Rinnai's official website for complete warranty details.

7.2 Customer Support

For technical assistance, troubleshooting, or warranty claims, please contact Rinnai Customer Support. High-quality, safe, and efficient appliances are a priority for Rinnai, and their customer support is available to assist you.

You can visit the Rinnai Store on Amazon for more information or to explore other Rinnai products.

Related Documents - EX17CTP

Preview Rinnai EX38CT Direct Vent Wall Furnace Installation and Operation Manual
This manual provides comprehensive installation, operation, and maintenance instructions for the Rinnai EX38CT Direct Vent Wall Furnace (RHFE-1005FTA2). It includes safety guidelines, troubleshooting, and warranty information for licensed professionals and consumers.
Preview Rinnai Gas Direct Vent Wall Furnace Limited Warranty - EX17CT, EX22CT
Official limited warranty document for Rinnai Gas Direct Vent Wall Furnaces, including models EX17CT and EX22CT. Details coverage, exclusions, and service procedures.
Preview Rinnai EX17DT/EX22DT Direct Vent Wall Furnace Installation and Operation Manual
Detailed installation and operation guide for Rinnai Direct Vent Wall Furnaces, models EX17DT and EX22DT. Covers safety, specifications, installation, operation, maintenance, troubleshooting, and warranty information.
Preview Rinnai 2001 Radiant Convection Heater: Installation and Operating Manual
Comprehensive guide for installing and operating the Rinnai 2001 Radiant/Convection space heater. Includes features, safety information, installation procedures, and troubleshooting.
Preview Rinnai Novo DV Inbuilt Gas Fireplace Installation Guide (RDV2320MN/L, RDV2320CN/L)
This comprehensive installation guide provides detailed instructions for the Rinnai Novo DV direct vent inbuilt gas fireplaces (Models RDV2320MN/L, RDV2320CN/L). It covers essential information on specifications, positioning, clearances, gas and electrical connections, flueing options, burn media installation, commissioning, Wi-Fi module setup, and safety precautions. Ensure a safe and correct installation by following these Rinnai guidelines.
Preview Rinnai Granada 252 (REH-252UCH2) Portable Radiant/Convection Gas Space Heater: Operation & Installation Manual
This manual provides comprehensive instructions for the Rinnai Granada 252 (REH-252UCH2) portable radiant/convection gas space heater. It covers installation, operation, safety precautions, maintenance, and troubleshooting to ensure safe and efficient use.