1. Introduction
This manual provides detailed instructions for the safe and effective use of your BTMETER BT-960C Mini Digital Infrared Thermometer. This device is designed for non-contact surface temperature measurement across a wide range of applications, including food preparation, grilling, and general household use. It is not intended for measuring human body temperature.
2. Safety Information
- Do not point the infrared sensor at eyes or directly at people.
- Keep the device away from extreme temperatures, humidity, or direct sunlight.
- Do not immerse the device in water or other liquids.
- This thermometer is for surface temperature measurement only and is not suitable for medical use or measuring human body temperature.
- Keep out of reach of children.
3. Product Overview
The BTMETER BT-960C is a compact, pen-style infrared thermometer featuring a digital display and a pocket clip for portability. It offers quick and accurate temperature readings without direct contact.
Key Features:
- Instant Read: Provides temperature readings in approximately 0.5 seconds.
- Wide Temperature Range: Measures from -30℃ to 275℃ (-22℉ to 527℉).
- Non-Contact Measurement: Utilizes a sensitive IR temperature sensor. Ideal testing distance is 30mm to 40mm.
- Switchable Units: Easily switch between Celsius (℃) and Fahrenheit (℉).
- Data Hold: Freezes the current reading on the display.
- Auto Power Off: Conserves battery life by automatically shutting down after a period of inactivity.
- Memory Function: Remembers the previously used temperature unit.
- Compact Design: Pen-type with a pocket clip for convenient carrying.

Figure 1: BTMETER BT-960C Mini Digital Infrared Thermometer.
4. Setup
Battery Installation:
The BT-960C thermometer requires two LR44 button batteries. To install or replace batteries:
- Remove the cap from the end of the thermometer opposite the probe. This cap also serves as an extended handle.
- Locate the battery compartment.
- Insert two LR44 batteries, ensuring correct polarity (+/-).
- Replace the cap securely.

Figure 2: View of the battery compartment with the cap removed.
Video 1: Demonstrates battery installation and basic operation of the BT-960C thermometer.
5. Operating Instructions
5.1. Turning On/Off
Press the 'MEAS' button to turn on the thermometer. The device will automatically power off after a period of inactivity to save battery life.
5.2. Taking a Measurement
- Point the infrared sensor towards the surface you wish to measure. The ideal testing distance is 30mm to 40mm.
- Press and hold the 'MEAS' button. The display will show the real-time temperature.
- Release the 'MEAS' button to hold the current reading on the screen.

Figure 3: The thermometer displaying a temperature reading with the 'HOLD' function active.
5.3. Switching Temperature Units (℃/℉)
To switch between Celsius (℃) and Fahrenheit (℉), locate the ℃/℉ button on the back of the device and press it. The display will update to the selected unit. The device remembers the last used unit.

Figure 4: Illustration of switching between Celsius and Fahrenheit temperature units.
5.4. Max/Min/Avg Functions
The thermometer features buttons for 'MAX/MIN' to display the maximum or minimum temperature recorded during a continuous measurement session. Refer to the on-screen indicators for these modes.
6. Maintenance
6.1. Cleaning
To clean the thermometer, wipe it with a soft, damp cloth. Do not use abrasive cleaners or immerse the device in water. Ensure the infrared sensor lens is clean for accurate readings.
6.2. Battery Replacement
When the battery indicator on the display shows low power, replace the LR44 batteries as described in the 'Battery Installation' section (Section 4).
7. Troubleshooting
- Inaccurate Readings: Ensure the sensor lens is clean and the measurement distance is within the ideal range (30-40mm). Check for any obstructions between the thermometer and the target surface.
- Display Defaults to Celsius: If the unit consistently reverts to Celsius, ensure you are pressing the ℃/℉ button correctly to select Fahrenheit. The device should remember your last setting. If the issue persists, try replacing the batteries.
- Error Codes/No Functionality: Check battery installation and replace with fresh batteries if necessary. If the device still does not function, contact customer support.
- Dim Display: Ensure batteries are fresh. The device may not have a dedicated backlight button, so optimal lighting conditions are recommended for viewing.
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | BT-960C |
| Temperature Range | -30℃ to 275℃ / -22℉ to 527℉ |
| Response Time | 0.5 seconds |
| Emissivity | 0.95 (fixed) |
| Resolution | 0.1℃ / 0.1℉ |
| Power Source | 2 x LR44 batteries |
| Auto Power Off | Yes |
| Display Type | LCD |
| Outer Material | Plastic |
| Dimensions | 6.26 x 1.89 x 1.65 inches |
| Weight | 1.13 ounces |
9. Warranty and Support
BTMETER products are backed by a 100% satisfaction guarantee. If you encounter any issues with your BT-960C thermometer, please contact BTMETER customer support for assistance or replacement.