1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of your TEMPCO Flexible Strip Heater. This heater is designed for applications requiring localized, flexible heating with an adhesive backing for easy mounting. Please read this manual thoroughly before use and retain it for future reference.
The TEMPCO Flexible Strip Heater operates on 120VAC, provides 140 Watts of heating power, and has an overall length of 9 inches. Its adhesive backing allows for secure attachment to various surfaces.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or property damage.
- Always disconnect power before installing, servicing, or cleaning the heater.
- Ensure the power supply matches the heater's specifications (120VAC).
- Do not operate the heater if it is damaged or if the insulation is compromised.
- Do not immerse the heater in liquids.
- Ensure proper ventilation around the heater to prevent overheating.
- Do not use the heater in explosive atmospheres or near flammable materials.
- Keep children and unauthorized personnel away from the heater during operation.
- Consult a qualified electrician for installation if you are unsure about electrical connections.
- The adhesive backing is for mounting; ensure the surface is clean, dry, and suitable for adhesion.
3. Setup and Installation
- Prepare the Surface:
Clean the surface where the heater will be mounted. Ensure it is free of dust, grease, moisture, and any other contaminants. A clean, dry, and smooth surface is crucial for optimal adhesive performance.
- Position the Heater:
Carefully determine the exact placement of the strip heater. Once the adhesive makes contact, repositioning may compromise its effectiveness.
- Apply the Heater:
Peel off the protective liner from the adhesive backing. Align the heater with the desired position and firmly press it onto the surface, working from one end to the other to avoid air bubbles. Apply even pressure across the entire length of the heater.
- Electrical Connection:
Connect the heater's leads to a 120VAC power source. Ensure all electrical connections are secure and comply with local electrical codes. It is recommended to use a fused circuit appropriate for the heater's wattage (140W).
- Verify Installation:
Double-check all connections and ensure the heater is securely mounted before applying power.
4. Operating Instructions
Once properly installed and connected to a 120VAC power source, the TEMPCO Flexible Strip Heater will begin to generate heat. This heater is designed for continuous operation within its specified temperature limits.
- Apply power to the circuit connected to the heater.
- Monitor the initial heating to ensure proper function and to confirm the desired temperature is being achieved in the application area.
- If temperature control is required, integrate an external temperature controller (not included) into the power circuit.
- To turn off the heater, disconnect power from the circuit.
5. Maintenance
The TEMPCO Flexible Strip Heater requires minimal maintenance. Regular inspection is recommended to ensure optimal performance and safety.
- Periodic Inspection: Regularly inspect the heater and its connections for any signs of damage, wear, or loose wiring.
- Cleaning: Ensure power is disconnected before cleaning. Gently wipe the surface of the heater with a dry, soft cloth to remove dust or debris. Do not use abrasive cleaners or solvents.
- Adhesion Check: Periodically check the adhesive bond to ensure the heater remains securely attached to the surface.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Heater not generating heat. | No power supply; Loose electrical connections; Damaged heater element. | Check power source and circuit breaker; Secure all electrical connections; Inspect heater for visible damage. If damaged, replace the heater. |
| Heater not adhering properly. | Improper surface preparation; Contaminated adhesive; Surface material incompatibility. | Ensure surface is clean, dry, and smooth before application. If adhesion fails, consider additional mechanical fastening methods or replacement. |
| Overheating. | Insufficient ventilation; Incorrect application; No temperature control. | Ensure adequate airflow around the heater. Verify the heater is suitable for the application. Consider installing an external temperature controller. |
If troubleshooting steps do not resolve the issue, contact TEMPCO customer support.
7. Specifications
| Brand | TEMPCO |
| Model | Flexible Strip Heater |
| Voltage | 120VAC |
| Wattage | 140 Watts |
| Overall Length | 9 inches |
| Mounting | Adhesive Backing |
| ASIN | B07HLXZ6V |
8. Warranty and Support
For warranty information and technical support, please contact TEMPCO directly through their official website or customer service channels. Keep your purchase receipt as proof of purchase.
For further assistance, visit the official TEMPCO website: www.tempco.com





