Green Cell AGM06

Green Cell AGM06 12V 9Ah VRLA Rechargeable Lead-Acid Battery User Manual

1. Product Overview

The Green Cell AGM06 is a 12V 9Ah Absorbent Glass Mat (AGM) Valve Regulated Lead-Acid (VRLA) rechargeable battery. This battery is designed for both cyclic and buffer applications, offering reliable and stable power. Its sealed, maintenance-free, and leak-proof construction ensures safety and a long operational life.

Green Cell AGM06 12V 9Ah VRLA battery

Image 1.1: Green Cell AGM06 12V 9Ah VRLA battery. This image displays the overall appearance of the battery.

Key Features:

  • AGM VRLA Technology: Ensures maintenance-free and leak-proof operation.
  • Versatile Use: Suitable for both cyclic (frequent charge/discharge) and buffer (standby power) applications.
  • Stable Performance: Provides consistent 12V output with 9Ah capacity.
  • Durability: Vibration-resistant and maintains performance across various temperatures.
  • Compact Design: Dimensions of 151x65x95mm with Faston 250 (F2) terminals.

Typical Applications:

  • Uninterruptible Power Supplies (UPS/ASI)
  • Alarm Systems and Video Surveillance
  • Photovoltaic and Off-grid Solar Systems
  • Children's Electric Vehicles, Toy Motorcycles, Quads
  • Electric Wheelchairs

2. Safety Instructions

Read and understand all safety instructions before using the battery. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Do Not Short-Circuit: Avoid connecting the positive and negative terminals directly, as this can cause severe damage to the battery and pose a fire hazard.
  • Keep Away from Water and Heat: Do not expose the battery to water, excessive moisture, or high temperatures.
  • Do Not Disassemble: The battery is sealed and maintenance-free. Do not attempt to open or disassemble the battery pack.
  • Proper Ventilation: Although VRLA batteries are sealed, ensure adequate ventilation if used in an enclosed space to prevent gas accumulation in case of malfunction.
  • Handle with Care: The battery contains lead. Avoid dropping or subjecting it to strong impacts.
  • Recycle Properly: Do not dispose of the battery in household waste. Always recycle lead-acid batteries at designated collection points.
Back label of Green Cell AGM06 battery with safety warnings

Image 2.1: Back label of the Green Cell AGM06 battery, showing constant voltage charge parameters and safety warnings such as 'Do not short-circuit' and 'Do not dispose of'.

3. Setup and Installation

Follow these general guidelines for installing your Green Cell AGM06 battery. Specific installation steps may vary depending on the device or system you are connecting it to.

  1. Inspect the Battery: Before installation, visually inspect the battery for any signs of damage, cracks, or leaks. Do not install a damaged battery.
  2. Prepare the Device: Ensure the device or system where the battery will be installed is turned off and disconnected from any power source.
  3. Identify Terminals: The battery features Faston 250 (F2) terminals. Identify the positive (+) and negative (-) terminals on both the battery and your device. The positive terminal is typically marked with a red indicator or a plus sign, and the negative with a black indicator or a minus sign.
  4. Connect Cables: Connect the positive cable from your device to the positive terminal of the battery. Then, connect the negative cable from your device to the negative terminal of the battery. Ensure connections are secure and tight to prevent arcing or poor performance.
  5. Secure the Battery: Place the battery in a stable position within the device, ensuring it is secured to prevent movement or vibration during operation.
  6. Initial Charge: For optimal performance, it is recommended to fully charge the battery before its first use. Refer to the 'Operation' section for charging parameters.
Person installing Green Cell battery in a red toy car

Image 3.1: A person installing the Green Cell AGM06 battery into the battery compartment of a red electric toy car, demonstrating a typical application.

Close-up of Green Cell battery being installed in a device

Image 3.2: A close-up view of hands connecting the Green Cell AGM06 battery within a device, showing the terminals and wiring.

4. Operation

The Green Cell AGM06 battery is designed for reliable performance in various modes of operation.

Charging Instructions:

Always use a charger compatible with 12V lead-acid batteries. Incorrect charging can reduce battery life or cause damage.

  • Constant Voltage Charge: This is the recommended charging method.
  • Cycle Use: For applications involving regular discharge and recharge cycles, charge between 14.4V and 14.9V.
  • Standby Use (Buffer): For applications where the battery is kept fully charged and used as a backup, charge between 13.5V and 13.8V.
  • Initial Current: The initial charging current should be less than 2.7A.
Green Cell AGM06 battery with icons indicating safety in enclosed spaces and super long lifetime

Image 4.1: The Green Cell AGM06 battery highlighting its suitability for enclosed spaces and its super long lifetime, indicating reliable operation.

Operational Modes:

  • Cyclic Use: The battery is designed to withstand repeated charge and discharge cycles, making it suitable for portable devices, electric vehicles, and other applications requiring regular power delivery.
  • Buffer Use: In standby applications, the battery provides emergency power during outages, such as in UPS systems, alarm systems, and emergency lighting.

5. Maintenance

The Green Cell AGM06 battery is designed to be maintenance-free due to its VRLA (Valve Regulated Lead-Acid) and AGM (Absorbent Glass Mat) technology. This means there is no need to check electrolyte levels or add water.

General Care:

  • Keep Clean: Periodically wipe the battery casing with a dry cloth to remove dust and dirt. Ensure terminals are free from corrosion.
  • Avoid Over-Discharge: While the battery is robust, prolonged deep discharge can reduce its lifespan. Recharge promptly after use.
  • Temperature: Operate and store the battery within recommended temperature ranges (typically 20-25°C for optimal life). Extreme temperatures can affect performance and lifespan.
  • Storage: If storing the battery for an extended period, ensure it is fully charged and stored in a cool, dry place. Recharge every 3-6 months to prevent self-discharge and maintain capacity.
Green Cell AGM06 battery with 'Super long lifetime' icon

Image 5.1: The Green Cell AGM06 battery, emphasizing its super long lifetime, which is supported by its maintenance-free design and robust construction.

6. Troubleshooting

This section addresses common issues you might encounter with your Green Cell AGM06 battery.

ProblemPossible CauseSolution
Battery not chargingFaulty charger, loose connections, deeply discharged battery.Check charger functionality and connections. If deeply discharged, try a specialized charger with a recovery mode or consult a professional.
Short operating time after full chargeBattery aging, frequent deep discharges, incorrect charging.Ensure proper charging parameters are used. If the battery is old, it may be reaching the end of its lifespan and require replacement.
Battery terminals corrodedExposure to moisture, loose connections.Clean terminals with a wire brush and a mixture of baking soda and water. Ensure connections are tight.
Battery casing is swollen or damagedOvercharging, internal fault, excessive heat.Immediately discontinue use. This indicates a serious internal issue. The battery is unsafe and must be replaced and recycled properly.

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact customer support or a qualified technician.

7. Specifications

Detailed technical specifications for the Green Cell AGM06 12V 9Ah VRLA battery.

Green Cell AGM06 battery with dimensions labeled

Image 7.1: The Green Cell AGM06 battery with its physical dimensions (length, width, height) clearly indicated in millimeters.

SpecificationValue
Model NumberAGM06
Voltage12V
Capacity9Ah
TechnologyAGM VRLA (Absorbent Glass Mat Valve Regulated Lead-Acid)
Terminal TypeFaston 250 (F2)
Maximum Charge Current2.7A
Internal Resistance (at 25°C)≤25 mΩ
Dimensions (L x W x H)151 x 65 x 95 mm
Weight1.65 kg
Expected LifespanMore than 5 years (in optimal conditions)
ManufacturerCSG S.A. (Green Cell)

8. Warranty and Support

Warranty Information:

The Green Cell AGM06 battery comes with a 2-year manufacturer's warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

Customer Support:

For technical assistance, warranty claims, or further inquiries, please refer to the contact information provided with your purchase or visit the official Green Cell website. When contacting support, please have your product model (AGM06) and purchase details ready.

9. Related Product Video

This video provides additional information about hermetic lead-acid batteries and their applications, which may be relevant to your Green Cell AGM06 battery.

Video 9.1: An informational video titled "Tecnoware Hermetische loodbatterij 12V 9Ah - voor UPS, Alarm- en camerabewakingssystemen - Faston...". This video demonstrates the applications and features of a 12V 9Ah hermetic lead-acid battery, suitable for UPS, alarm, and video surveillance systems.

Ask a question about this manual