1. Introduction
This manual provides essential information for the safe and effective operation of your Ingco DM200 Digital Multimeter. Please read this manual thoroughly before use and retain it for future reference. The Ingco DM200 is a compact, battery-powered digital multimeter designed for measuring DC/AC voltage, DC current, resistance, diode, and continuity.
2. Safety Information
Always observe basic safety precautions when using this multimeter to avoid personal injury or damage to the meter or equipment under test.
- Do not exceed the maximum input values for any range.
- Use caution when working with voltages above 60V DC or 30V AC RMS, as these pose a shock hazard.
- Ensure the test leads are properly seated in the correct input terminals for the desired measurement.
- Do not use the meter if it is damaged or if the test leads are damaged.
- Always turn off the circuit power and discharge all high-voltage capacitors before measuring resistance, diodes, or continuity.
- Replace the battery immediately when the low battery indicator appears to ensure accurate readings.
3. Product Overview
The Ingco DM200 Digital Multimeter features a clear LCD display, a rotary switch for function selection, and input jacks for test leads. It is designed for ease of use and reliability in various electrical testing scenarios.

Image: The Ingco DM200 Digital Multimeter in use, measuring voltage from a power strip. The display shows '220 AC V'.

Image: The Ingco DM200 Digital Multimeter highlighting its multiple functions, including resistance, current, diode, and continuity measurements.
4. Setup
4.1. Battery Installation
The DM200 is powered by batteries. To install or replace batteries:
- Ensure the multimeter is turned OFF.
- Locate the battery compartment cover on the back of the unit.
- Unscrew the retaining screw(s) and remove the cover.
- Insert new batteries, observing the correct polarity (+/-).
- Replace the cover and secure it with the screw(s).
4.2. Connecting Test Leads
Connect the red test lead to the 'VΩmA' jack and the black test lead to the 'COM' jack for most voltage, resistance, and low current measurements. For high current (up to 10A) measurements, connect the red test lead to the '10A' jack and the black test lead to the 'COM' jack.
5. Operating Instructions
5.1. Powering On/Off
Turn the rotary switch from the 'OFF' position to any desired function to power on the multimeter. To power off, turn the rotary switch back to the 'OFF' position.
5.2. Function Selection
Rotate the central dial to select the desired measurement function (e.g., DCV, ACV, DCA, Resistance, Diode, Continuity).

Image: A user wearing gloves operating the Ingco DM200 Digital Multimeter, measuring voltage in an electrical panel. The display shows '393 AC V'.
5.3. Measuring DC Voltage (DCV)
- Connect the red test lead to 'VΩmA' and the black test lead to 'COM'.
- Set the rotary switch to the desired DCV range (e.g., 200mV, 2V, 20V, 200V, 600V).
- Connect the test leads across the DC voltage source to be measured.
- Read the voltage value on the LCD display.
5.4. Measuring AC Voltage (ACV)
- Connect the red test lead to 'VΩmA' and the black test lead to 'COM'.
- Set the rotary switch to the desired ACV range (e.g., 200V, 600V).
- Connect the test leads across the AC voltage source to be measured.
- Read the voltage value on the LCD display.
5.5. Measuring DC Current (DCA)
- For low current (μA/mA): Connect the red test lead to 'VΩmA' and the black test lead to 'COM'.
- For high current (10A): Connect the red test lead to '10A' and the black test lead to 'COM'.
- Set the rotary switch to the desired DCA range (e.g., 200μA, 20mA, 200mA, 10A).
- Open the circuit where current is to be measured and connect the multimeter in series with the load.
- Read the current value on the LCD display.
5.6. Measuring Resistance (Ω)
- Ensure the circuit is de-energized before measuring resistance.
- Connect the red test lead to 'VΩmA' and the black test lead to 'COM'.
- Set the rotary switch to the desired Resistance range (e.g., 200Ω, 2kΩ, 200kΩ, 2MΩ).
- Connect the test leads across the component to be measured.
- Read the resistance value on the LCD display.
5.7. Diode Test
- Ensure the circuit is de-energized.
- Connect the red test lead to 'VΩmA' and the black test lead to 'COM'.
- Set the rotary switch to the Diode symbol.
- Connect the red test lead to the anode and the black test lead to the cathode of the diode.
- Read the forward voltage drop on the display. Reverse the leads to check for open circuit (OL).
5.8. Continuity Test
- Ensure the circuit is de-energized.
- Connect the red test lead to 'VΩmA' and the black test lead to 'COM'.
- Set the rotary switch to the Continuity symbol.
- Connect the test leads across the component or circuit path.
- If the resistance is below approximately 50Ω, the buzzer will sound, indicating continuity.
5.9. Data Hold Function
Press the 'HOLD' button to freeze the current reading on the display. Press it again to release the hold function.
5.10. Backlight Function
Press the backlight button (often indicated by a sun or light bulb symbol) to illuminate the LCD display for better visibility in low-light conditions. Press it again to turn off the backlight.

Image: The Ingco DM200 Digital Multimeter with its LCD backlight activated, making readings clear in dark environments.
6. Maintenance
6.1. Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the input terminals free of dirt and moisture.
6.2. Battery Replacement
When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Prompt battery replacement ensures measurement accuracy.
6.3. Storage
If the meter is not to be used for an extended period, remove the batteries to prevent leakage and damage to the unit. Store the multimeter in a cool, dry place.
7. Troubleshooting
- No display or faint display: Check battery installation and charge. Replace batteries if necessary.
- 'OL' (Overload) displayed: The input value exceeds the selected range. Select a higher range or check if the circuit is open.
- Inaccurate readings: Ensure test leads are properly connected. Check battery level. Ensure the correct function and range are selected.
- No continuity beep: Check if the circuit is open or if the resistance is too high.
8. Specifications
The Ingco DM200 Digital Multimeter offers the following technical specifications:

Image: The Ingco DM200 Digital Multimeter with a list of its key features and specifications.
| Feature | Specification |
|---|---|
| Display Counts | 1999 |
| DC Voltage | 200mV / 2V / 20V / 200V / 600V |
| AC Voltage | 200V / 600V |
| DC Current | 200μA / 20mA / 200mA / 10A |
| Resistance | 200Ω / 2kΩ / 200kΩ / 2MΩ |
| Diode Test | Yes |
| Continuity Test | Yes (with buzzer) |
| Backlight | Yes |
| Data Hold | Yes |
| Low Battery Indication | Yes |
| Auto Power Off | Yes |
| Power Source | Battery Powered |
| Safety Rating | CAT III 600V, CE Marked |
| Dimensions (L x W x H) | 23 x 11.7 x 4.9 cm |
| Weight | 1 Kilogram |
9. Warranty
The Ingco DM200 Digital Multimeter comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and faulty materials under normal use. It does not cover damage caused by misuse, accident, unauthorized repair, or normal wear and tear. Please retain your proof of purchase for warranty claims.

Image: An official Ingco badge indicating a 1-year warranty for the product.
10. Support
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Ingco customer support through their official website or authorized service centers. Always refer to the model number DM200 when seeking support.
Official Website: www.ingco.com