1. Product Overview

The Johnson Controls EP-8000-1 Electro-Pneumatic Transducer is designed to convert an electrical input signal into a proportional pneumatic output pressure signal. Specifically, this model accepts a 10-20 VDC input and produces an 18-25 psi pneumatic output. It is part of the EP-8000 series, which offers both low-volume (non-relay) and high-volume (relay) output units.

Johnson Controls EP-8000 series Electro-Pneumatic Transducer

Figure 1: A Johnson Controls EP-8000 series Electro-Pneumatic Transducer (specifically showing an EP-8000-2 model, representative of the EP-8000-1). This image shows the compact, cylindrical device with electrical connections at the bottom and pneumatic ports on the side, along with labeling for input/output and adjustment points.

2. Key Features

  • Hypodermic Needle Test Point: Allows for easy and precise measurement of the output pressure signal.
  • Barbed Air Connections: Designed for secure attachment of 5/32 inch or 1/4 inch O.D. polytubing.
  • Compact and Simple Design: Facilitates straightforward installation on various mounting surfaces, including direct mounting on pneumatic valve actuators.
  • Factory Set, Adjustable Zero and Span: Enables convenient field calibration to ensure accurate performance.

3. Installation Guide

Proper installation is crucial for the optimal performance of the EP-8000-1 transducer. Follow these guidelines:

  1. Mounting: Select a suitable mounting surface. The compact design allows for direct mounting on pneumatic valve actuators or other flat surfaces. Ensure the mounting is secure and stable.
  2. Electrical Connections: Connect the 10-20 VDC input signal from your electric controller to the designated electrical terminals on the transducer. Refer to the wiring diagram provided with the product for correct polarity and terminal assignments.
  3. Pneumatic Connections: Attach 5/32 inch or 1/4 inch O.D. polytubing to the barbed air connections for the pneumatic output. Ensure connections are tight to prevent leaks.
  4. Air Supply: Connect a clean, dry, regulated air supply to the transducer's input port. The pressure range for the air supply should be within the transducer's specified limits.
  5. Initial Calibration (Zero and Span): While the unit is factory-set, field calibration may be necessary for specific applications. Use the accessible zero and span adjustment points to fine-tune the output pressure signal. A hypodermic needle can be used with the test point for accurate output pressure measurement during calibration.

Note: Always ensure power is disconnected before making any electrical connections. Consult local electrical codes and safety standards.

4. Operation

The EP-8000-1 transducer operates by converting a 10-20 VDC electrical input signal into a proportional 18-25 psi pneumatic output pressure. Once installed and calibrated, the unit will automatically adjust its pneumatic output based on the electrical input it receives from the control system.

  • Input Signal: The transducer continuously monitors the 10-20 VDC input signal.
  • Pneumatic Output: In response to the electrical input, the transducer modulates its internal components to produce a corresponding pneumatic pressure output within the 18-25 psi range.
  • Monitoring: The hypodermic needle test point can be used to verify the pneumatic output pressure at any time during operation.

5. Maintenance

The Johnson Controls EP-8000-1 is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure longevity and consistent performance.

  • Regular Inspection: Periodically inspect the transducer for any signs of physical damage, loose connections, or air leaks in the pneumatic tubing.
  • Cleaning: Keep the exterior of the unit clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Air Quality: Ensure the air supply to the transducer is clean and dry. Contaminants in the air supply can affect performance and lifespan.
  • Recalibration: If the output pressure appears inaccurate or drifts over time, recalibrate the zero and span settings as described in the Installation Guide.

6. Troubleshooting

If the EP-8000-1 transducer is not functioning as expected, consider the following troubleshooting steps:

  • No Pneumatic Output:
    • Verify electrical input (10-20 VDC) is present and correctly wired.
    • Check for a stable and sufficient air supply pressure.
    • Inspect pneumatic connections for leaks or blockages.
  • Incorrect Pneumatic Output:
    • Confirm the electrical input signal is within the specified 10-20 VDC range.
    • Recalibrate the zero and span settings.
    • Ensure the air supply pressure is stable and within the recommended range.
    • Check for any physical damage to the transducer.
  • Intermittent Operation:
    • Check all electrical and pneumatic connections for looseness.
    • Ensure the power supply to the electrical controller is stable.
    • Verify the air supply is free from moisture or contaminants.

If issues persist after performing these checks, contact Johnson Controls technical support.

7. Technical Specifications

SpecificationValue
Model NumberEP-8000-1
Input Signal10-20 VDC
Pneumatic Output18-25 psi (proportional)
Product Dimensions5 x 3 x 5 inches
Item Weight3.52 ounces
ManufacturerJohnson Controls Inc
First Available DateJuly 5, 2012
Air ConnectionsBarbed for 5/32 or 1/4 inch O.D. polytubing
CalibrationFactory set, fully adjustable zero and span

8. Warranty and Support

For detailed warranty information regarding your Johnson Controls EP-8000-1 Pneumatic Transducer, please refer to the documentation included with your purchase or visit the official Johnson Controls website. For technical assistance, troubleshooting beyond the scope of this manual, or to inquire about replacement parts, please contact Johnson Controls customer support directly.

Johnson Controls Official Website: www.johnsoncontrols.com

© 2023 Johnson Controls. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.