ELEKTRO-PLAST AK3-AT1-GL-M-X
ELEKTROPLAST AK3-AT1-GL-M-X Circuit Breaker Panel User Manual
Model: AK3-AT1-GL-M-X (2208-01: 1-reihig für 17 Module)
1. Introduction
This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of your ELEKTROPLAST AK3-AT1-GL-M-X Circuit Breaker Panel. This stable fuse box is constructed from ABS plastic, making it ideal for installation in damp rooms and outdoors due to its IP65 protection class.
Key features include:
- Integrated top-hat rail with space for 16 circuit breakers (16TE).
- Integrated PE+N terminals.
- Transparent, darkened front door for visibility of internal components.
- Multiple cable entry points on the side, top, and bottom.
- Spacious interior for convenient wiring.
2. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel in accordance with all local and national electrical codes.
- Always disconnect power at the main service panel before installing or servicing the circuit breaker panel.
- Use appropriate personal protective equipment (PPE), including insulated gloves and safety glasses.
- Ensure all connections are secure and properly insulated.
- Do not operate the panel if it is damaged or if any components are missing.
3. Setup and Installation
The ELEKTROPLAST AK3-AT1-GL-M-X is designed for screw-in installation.
3.1 Mounting
The panel is suitable for both indoor and outdoor use, including damp environments, thanks to its IP65 protection rating. Securely mount the panel to a stable surface using appropriate screws through the designated mounting points. Ensure the mounting surface can support the weight of the panel and its contents.
3.2 Cable Entry
The enclosure features pre-marked or knock-out cable entry points on the side, top, and bottom. Select the appropriate entry points for your wiring needs. Use suitable cable glands or conduits to maintain the IP65 rating and protect wiring from environmental factors.
3.3 Internal Wiring
The spacious interior of the panel facilitates easy wiring. Install circuit breakers onto the integrated top-hat rail. Connect the PE (Protective Earth) and N (Neutral) conductors to the integrated PE+N terminals as required by your electrical system design and local codes.

Figure 1: ELEKTROPLAST AK3-AT1-GL-M-X Circuit Breaker Panel. This image shows a white, rectangular ELEKTROPLAST circuit breaker panel with a transparent, darkened front door. The panel features screw holes for mounting and visible cable entry points on the sides and top. The clear door allows visibility of internal components, such as the DIN rail and terminals.
4. Operation
The ELEKTROPLAST AK3-AT1-GL-M-X panel is designed for straightforward operation.
4.1 Accessing Circuit Breakers
The transparent, darkened front door provides a clear view of the installed circuit breakers and their status indicators without needing to open the panel. To access the circuit breakers for switching or maintenance, unlatch and open the front door. Ensure the door is securely latched shut after use to maintain the IP65 protection.
4.2 Circuit Breaker Functionality
Operate the circuit breakers according to their individual manufacturer's instructions. The integrated top-hat rail is designed to securely hold standard DIN rail mounted circuit breakers and other modular devices.
5. Maintenance
Regular maintenance ensures the longevity and safe operation of your circuit breaker panel.
5.1 Cleaning
Clean the exterior of the panel periodically with a soft, damp cloth. Avoid using abrasive cleaners or solvents that could damage the plastic material or the transparent door. Ensure the panel is dry before re-energizing if power was disconnected for cleaning.
5.2 Inspection
Periodically inspect the panel for any signs of damage, such as cracks in the housing or door, loose screws, or corrosion. Check that all cable glands are tight and that the door seal is intact to maintain the IP65 rating. If any damage is found, consult a qualified electrician for repair or replacement.
6. Troubleshooting
If you experience issues with your circuit breaker panel, consider the following:
- No Power to Circuits: Check if the main circuit breaker or individual branch circuit breakers are tripped. Reset them if necessary. Ensure the main power supply to the panel is active.
- Frequent Tripping: This may indicate an overload or a short circuit in the connected electrical system. Consult a qualified electrician to diagnose and resolve the underlying issue.
- Water Ingress: If water is found inside the panel, immediately disconnect power and contact a qualified electrician. This indicates a breach in the IP65 seal, which must be repaired to prevent hazards.
For any complex electrical issues, always consult a qualified and licensed electrician. Do not attempt repairs beyond your expertise.
7. Specifications
| Attribute | Detail |
|---|---|
| Brand | ELEKTRO-PLAST |
| Model Number | AK3-AT1-GL-M-X |
| Size | 2208-01: 1-reihig für 17 Module |
| Material | Plastic (ABS) |
| Color | Klar (Clear) |
| Style | Protection |
| Product Dimensions (D x W x H) | 5.43"D x 10.63"W x 5.43"H |
| Finish Type | Polished |
| Installation Type | Screw-in (Einschrauben) |
| Item Weight | 1.67 Kilograms / 3.67 pounds |
| Specification Met | Watersense (Note: This specification may be atypical for this product type.) |
| Manufacturer | Elektro Plast |
| Part Number | SB-122 |
| Item Package Quantity | 1 |
| Batteries Included/Required | No |
| Date First Available | September 18, 2020 |
8. Warranty and Support
For information regarding product warranty, technical support, or replacement parts, please contact ELEKTRO-PLAST customer service directly. Refer to the product packaging or the manufacturer's official website for contact details.