1. Introduction
This manual provides detailed instructions for the installation, configuration, and operation of the BFT ALENA SW2 D113811 00004 control board. This control unit is designed for managing one or two 230V gate operators. Please read this manual carefully before proceeding with installation or operation to ensure proper functionality and safety.
2. Safety Information
Important Safety Instructions:
- Installation and maintenance must be performed by qualified personnel only.
- Disconnect power before performing any work on the control board or connected operators.
- Ensure all electrical connections comply with local regulations and standards.
- Keep children and unauthorized persons away from the gate area during operation.
- Regularly check the system for proper operation and safety device functionality.
3. Product Overview
The BFT ALENA SW2 D113811 00004 is a sophisticated control board featuring dip switches and potentiometers for precise configuration. It includes extractable terminal blocks for easier wiring, an integrated radio receiver for remote control, and supports pedestrian opening functionality. The board incorporates safety verification and self-diagnosis features to ensure reliable operation.
Figure 1: Placeholder image for the BFT ALENA SW2 D113811 00004 Control Board. This image indicates that a specific product image is not available.
Key Features:
- Control for one or two 230V operators.
- Extractable terminal blocks with color-coded standard for simplified wiring.
- Dip switch and potentiometer programming for precise adjustments.
- Integrated radio receiver for remote control operation.
- Pedestrian opening function.
- Safety verification and self-diagnosis capabilities.
4. Setup and Installation
4.1 Mounting the Control Board:
- Choose a suitable, protected location for mounting the control board, away from direct weather exposure.
- Secure the control board enclosure firmly using appropriate fasteners.
4.2 Electrical Connections:
- Ensure the main power supply is disconnected before making any connections.
- Connect the 230V AC power supply to the designated terminal blocks. Refer to the wiring diagram provided with the product for specific terminal assignments.
- Connect the gate operator(s) motors to the respective output terminals.
- Wire all safety devices (e.g., photocells, safety edges) to their dedicated input terminals.
- Connect any command devices (e.g., push buttons, key switches) to the appropriate input terminals.
- Utilize the extractable, color-coded terminal blocks for organized and secure wiring.
4.3 Initial Configuration (Dip Switches and Potentiometers):
- Refer to the detailed wiring and configuration diagrams included with your product for specific settings.
- Use the dip switches to select the desired operating logic (e.g., 3-step, 4-step, automatic closing).
- Adjust potentiometers for parameters such as motor force, pause time, and sensitivity of safety devices.
- Perform a self-learning procedure for the gate travel limits if applicable to your operator model.
5. Operating Instructions
The BFT ALENA SW2 D113811 00004 control board supports various operating modes and functions:
- Standard Operation: Activate the gate using a remote control or wired command device. The gate will open or close according to the configured logic.
- Pedestrian Opening: If configured, a separate command can activate a partial opening of the gate for pedestrian access.
- Safety Device Activation: In case of obstruction detected by safety devices (e.g., photocells), the gate will stop or reverse its movement to prevent injury or damage.
- Integrated Radio Receiver: To program new remote controls, follow the specific instructions provided in the full product manual for pairing transmitters with the integrated receiver.
6. Maintenance
Regular maintenance ensures the longevity and safe operation of your gate system. Perform the following checks periodically:
- Visual Inspection: Check all wiring for signs of wear, damage, or loose connections. Ensure the control board enclosure is sealed and free from moisture or debris.
- Safety Device Test: Regularly test all safety devices (photocells, safety edges) to ensure they are functioning correctly.
- Operator Check: Inspect the gate operators for smooth movement, lubrication, and any unusual noises.
- Cleaning: Keep the control board and its components clean and free from dust. Use a soft, dry cloth for cleaning.
For any complex maintenance or repairs, contact a qualified technician.
7. Troubleshooting
This section provides guidance for common issues. For more complex problems, consult a qualified technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Gate does not respond to commands. | No power, faulty remote control, safety devices activated, loose wiring. | Check power supply. Replace remote battery or re-program. Inspect safety devices for obstructions. Verify all connections. |
| Gate stops unexpectedly. | Obstruction detected by safety devices, motor overload, incorrect force setting. | Clear any obstructions. Check motor for issues. Adjust motor force potentiometer. |
| Pedestrian opening not working. | Incorrect dip switch setting, faulty command input. | Verify dip switch configuration for pedestrian function. Test the command input device. |
The self-diagnosis feature of the ALENA SW2 board can provide error codes or indicators. Refer to the full product manual for a list of these codes and their meanings.
8. Specifications
- Manufacturer: B.F.T. S.P.A.
- Model Number: D113811 00004 (ALENA SW2)
- Power Supply: 230V (for one or two operators)
- Control Type: Dip switch and potentiometer based
- Features: Extractable terminal blocks, integrated radio receiver, pedestrian opening, safety verification, self-diagnosis.
- Package Dimensions: 0.01 x 0.01 x 0.01 cm
- Item Weight: 10 grams
- ASIN: B07G3BQRTX
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact BFT customer service directly. Keep your proof of purchase for warranty claims.