1. Introduction

Thank you for choosing the Geko G80426 Indirect Oil Heater. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your 40 kW indirect oil heater. Please read this manual thoroughly before operating the device and keep it for future reference.

This heater is designed for professional use in well-ventilated areas, providing clean, dry heat. It operates on a 220-240V / 50Hz power supply.

2. Important Safety Instructions

WARNING: Failure to follow these safety instructions may result in fire, electric shock, serious injury, or death.

  • Always operate the heater in a well-ventilated area to prevent carbon monoxide poisoning.
  • Ensure the power supply matches the heater's requirements (220-240V / 50Hz).
  • Do not use the heater near flammable materials, liquids, or gases. Maintain a safe distance from walls and other objects.
  • Never leave the heater unattended while in operation.
  • Keep children and pets away from the heater.
  • Do not block the air intake or exhaust outlets.
  • If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
  • Disconnect the heater from the power supply before performing any maintenance or cleaning.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

3. Components Overview

Familiarize yourself with the main parts of your Geko G80426 Indirect Oil Heater:

Geko G80426 Indirect Oil Heater, black and yellow, with exhaust chimney and control panel.
Figure 1: Geko G80426 Indirect Oil Heater. An image showing the Geko G80426 Indirect Oil Heater. The heater features a black cylindrical body with a silver exhaust chimney on top. It is mounted on a black fuel tank base with wheels, supported by a yellow tubular frame that also serves as a handle. A control panel with digital displays is visible on the side.
  • Heater Body: The main cylindrical part where combustion occurs and heat is generated.
  • Exhaust Chimney: Located on top of the heater body, for expelling combustion gases.
  • Fuel Tank: The base of the heater, containing the fuel.
  • Wheels: For easy portability of the unit.
  • Handle/Frame: Yellow tubular frame for moving the heater.
  • Control Panel: Includes power switch, digital displays, and possibly a thermostat control.
  • Fuel Cap: For refilling the fuel tank.

4. Setup

  1. Unpacking: Carefully remove the heater from its packaging. Inspect for any damage that may have occurred during transit.
  2. Placement: Position the heater on a stable, level, non-combustible surface. Ensure adequate clearance from walls, ceilings, and any flammable materials (minimum 1 meter from all sides).
  3. Ventilation: Ensure the operating area is well-ventilated. The exhaust chimney must be properly installed and vented to the outside atmosphere, away from windows or air intakes.
  4. Fueling: Fill the fuel tank with appropriate fuel (e.g., diesel, kerosene) using a clean funnel. Do not overfill. Ensure the fuel cap is securely closed after fueling.
  5. Power Connection: Connect the power cord to a grounded 220-240V / 50Hz electrical outlet. Ensure the outlet is capable of handling the heater's power requirements.

5. Operating Instructions

  1. Starting the Heater:
    • Ensure all safety precautions are met.
    • Turn the main power switch on the control panel to the "ON" position.
    • The heater will initiate its startup sequence. This may involve a pre-heating phase.
    • Once started, the burner will ignite, and warm air will begin to flow.
  2. Adjusting Temperature (if applicable): Use the thermostat control (if present on your model) to set the desired temperature. The heater will cycle on and off to maintain this temperature.
  3. Monitoring Operation: Periodically check the heater during operation to ensure it is functioning correctly and that the exhaust is clear.
  4. Shutting Down the Heater:
    • Turn the main power switch to the "OFF" position.
    • The heater will enter a cool-down cycle to protect components. Do not unplug the heater during this cycle.
    • Once the cool-down cycle is complete, the heater will shut down completely.
    • Disconnect the power cord from the outlet.

6. Maintenance

Regular maintenance ensures the longevity and safe operation of your heater. Always disconnect the power supply before performing any maintenance.

  • Daily/Before Each Use:
    • Check fuel level.
    • Inspect power cord for damage.
    • Ensure air intake and exhaust are clear of obstructions.
  • Weekly/After 50 Hours of Operation:
    • Clean the exterior of the heater with a damp cloth.
    • Check fuel filter for debris and clean or replace if necessary.
    • Inspect the burner nozzle for carbon buildup and clean if needed.
  • Monthly/After 200 Hours of Operation:
    • Inspect and clean the fan blades.
    • Check electrical connections for tightness.
    • Have a qualified technician inspect the combustion chamber and heat exchanger.
  • Storage: When not in use for extended periods, drain the fuel tank, clean the heater thoroughly, and store it in a dry, dust-free environment.

7. Troubleshooting

Before contacting customer support, please refer to the following common issues and solutions:

ProblemPossible CauseSolution
Heater does not start.No power; low fuel; faulty switch.Check power connection; refill fuel tank; contact service.
Heater starts but shuts off quickly.Lack of oxygen; clogged fuel filter; dirty nozzle.Ensure adequate ventilation; clean/replace fuel filter; clean nozzle.
Excessive smoke or unusual odor.Improper combustion; wrong fuel type; clogged exhaust.Shut down immediately; check fuel type; clear exhaust; contact service.
Heater runs but no heat.Ignition failure; burner issue.Contact qualified service personnel.

8. Specifications

  • Model: G80426
  • Brand: Geko
  • Power Output: 40 kW
  • Power Supply: 220-240V / 50Hz
  • Dimensions (Package): 35 x 35 x 15 cm
  • Weight (Package): 30 kg
  • Material: High-quality material
  • Country of Origin: Poland

9. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your retailer. Keep your proof of purchase for warranty claims.

For further assistance, please contact Geko customer service or an authorized service center.

© 2026 Geko. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.