uxcell DC 0-10V Analog Panel Voltage Gauge Volt Meter 91C4 Instruction Manual

Model: 91C4

1. Introduction

The uxcell 91C4 DC 0-10V Analog Panel Voltage Gauge is designed for measuring direct current (DC) voltage within a range of 0 to 10 volts. This instruction manual provides essential information for the safe installation, operation, and maintenance of the device. Please read this manual thoroughly before use.

2. Safety Information

Always observe the following safety precautions to prevent personal injury or damage to the meter and other equipment:

3. Product Overview

The uxcell 91C4 is a compact analog panel voltmeter featuring a clear scale and a moving coil mechanism. It is designed for flush panel mounting.

Front view of uxcell 91C4 DC 0-10V Analog Panel Voltmeter

Figure 1: Front view of the uxcell 91C4 DC 0-10V Analog Panel Voltmeter. This image displays the meter's face with its scale from 0 to 10 volts, the 'V' unit, the model number '91C4', and the accuracy class '2.5A'. The needle is positioned at zero, indicating no voltage input.

Dimensions of uxcell 91C4 DC 0-10V Analog Panel Voltmeter

Figure 2: Front and side view of the uxcell 91C4 DC 0-10V Analog Panel Voltmeter with key dimensions. The image shows the meter's width and height as 45mm (1.77 inches) and its depth as 36mm (1.42 inches), providing essential information for panel cutout and mounting.

4. Specifications

Model91C4
Measurement RangeDC 0-10V
Accuracy Class2.5 (Error Margin: ± 2.5%)
Graduation0.4V
Dimensions (L×W×T)45mm × 45mm × 36mm (1.77in × 1.77in × 1.42in)
Net Weight33g (1.16 oz)
Casing MaterialHigh-grade ABS Plastic
Shunt ResistorNot Required
Mounting TypePanel Mount

5. Setup and Installation

Follow these steps for proper installation of the voltage gauge:

  1. Prepare Panel Cutout: Create a square cutout in your panel with dimensions appropriate for the meter (approximately 45mm x 45mm). Ensure the cutout is clean and free of burrs.
  2. Insert Meter: Carefully insert the meter into the prepared panel cutout from the front.
  3. Secure Meter: From the rear of the panel, use the provided bolts and screws to secure the meter in place. Tighten them evenly to prevent damage to the meter casing.
  4. Rear view of uxcell 91C4 DC 0-10V Analog Panel Voltmeter with mounting hardware

    Figure 3: Rear view of the uxcell 91C4 DC 0-10V Analog Panel Voltmeter, illustrating the terminal posts and the included mounting hardware. This hardware, consisting of nuts, washers, and screws, is used to secure the meter firmly to a panel.

  5. Wiring:
    • Identify the positive (+) and negative (-) terminals on the back of the meter.
    • Connect the positive lead from the DC circuit to be measured to the meter's positive (+) terminal.
    • Connect the negative lead from the DC circuit to be measured to the meter's negative (-) terminal.
    • Ensure all connections are secure and insulated to prevent short circuits.
  6. Verify Connections: Double-check all wiring before applying power to the circuit.

6. Operating Instructions

Once installed and wired correctly, operating the uxcell 91C4 voltage gauge is straightforward:

  1. Apply Power: Turn on the power supply to the DC circuit being monitored.
  2. Read Measurement: The meter's needle will move across the scale to indicate the current DC voltage. Read the value directly from the scale.
  3. Close-up of uxcell 91C4 DC 0-10V Analog Panel Voltmeter scale

    Figure 4: Close-up view of the meter's face, emphasizing the clear voltage scale, the red needle, and the model markings. This detailed view assists users in accurately reading the measured voltage.

  4. Observe Range: Ensure the needle remains within the 0-10V range. Continuous operation above the maximum rated voltage may damage the meter.

7. Maintenance

The uxcell 91C4 voltage gauge requires minimal maintenance:

8. Troubleshooting

ProblemPossible CauseSolution
Meter needle does not move.No power to the circuit; incorrect wiring; meter malfunction.Verify power supply; check wiring for correct polarity and secure connections; if issues persist, meter may be faulty.
Meter needle shows incorrect reading.Incorrect wiring; meter calibration issue; external interference.Recheck wiring; ensure the measured voltage is within the meter's range; if possible, compare with a known accurate voltmeter.
Meter needle is stuck or erratic.Physical damage; internal component failure.Inspect for visible damage; if internal, meter may need replacement.

If troubleshooting steps do not resolve the issue, contact uxcell customer support.

9. Warranty and Support

For warranty information and technical support, please refer to the uxcell official website or contact their customer service department. Keep your purchase receipt for warranty claims.