Ving CWFL-1500

Industrial Water Chiller S&A CWFL-1500 User Manual

Model: CWFL-1500 | Brand: Ving (S&A)

1. Introduction

This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of the S&A CWFL-1500 Industrial Water Chiller. The CWFL-1500 is specifically designed for cooling 1500W fiber lasers, featuring dual independent refrigeration circuits to provide separate cooling for both the fiber laser and its laser head. Please read this manual thoroughly before operating the unit to ensure proper function and longevity.

S&A CWFL-1500 Industrial Water Chiller, front angled view

Figure 1: Front angled view of the S&A CWFL-1500 Industrial Water Chiller, showing the main unit with cooling fan on top, control panel, and caster wheels.

2. Safety Information

Always adhere to the following safety precautions to prevent injury or damage to the equipment.

3. Product Overview

The S&A CWFL-1500 chiller is designed for precise temperature control of fiber lasers. Key components and features include:

Front view of S&A CWFL-1500 chiller showing control panel and power switch

Figure 2: Front view of the S&A CWFL-1500, highlighting the digital control panel, power switch, and water pressure gauge.

Rear view of S&A CWFL-1500 chiller showing water inlets, outlets, and drain

Figure 3: Rear view of the S&A CWFL-1500, illustrating the various water inlet and outlet ports (Inlet L, Outlet L, Inlet H, Outlet H) and the drain valve.

4. Setup Instructions

  1. Unpacking: Carefully remove the chiller from its packaging. Inspect for any shipping damage.
  2. Placement: Position the chiller on a flat, stable surface. Ensure there is sufficient space (at least 20cm) around the unit for proper air circulation. The caster wheels allow for easy movement.
  3. Water Filling:
    • Locate the back-mounted fill port.
    • Fill the tank with approximately 14 liters of clean, pure, impurity-free water (e.g., purified water, distilled water, deionized water).
    • Monitor the visual water level indicator to avoid overfilling.
  4. Connecting to Laser System:
    • Connect the chiller's water inlets and outlets (Rp1/2" + Rp1/2") to the corresponding ports on your fiber laser and laser head. Ensure connections are secure and leak-free.
    • The dual circuits are typically labeled for high (H) and low (L) temperature requirements, corresponding to the laser head and fiber laser respectively.
  5. Power Connection: Connect the chiller to a dedicated AC 1P 220~240V, 50Hz power outlet. Ensure the power supply is stable and grounded.
  6. Refrigerant Charge: (Important Note: Refrigerant is not included.) The chiller requires 1100g of R-410a refrigerant. This must be charged by a certified HVAC technician before initial operation.

5. Operating Instructions

  1. Initial Power On: After completing all setup steps, turn on the main power switch. The digital temperature controllers will illuminate.
  2. Temperature Setting: The intelligent temperature control function will automatically adjust the water temperature within the range of 5°C to 35°C based on ambient temperature. Manual adjustments can be made via the digital controller interface if specific temperatures are required, referring to the controller's dedicated manual for detailed programming.
  3. Monitoring: Regularly check the digital display for current water temperatures and the water pressure gauge. Pay attention to any alarm indicators.
  4. Normal Operation: The chiller will maintain the set temperature by cycling the compressor and cooling fan as needed. The dual circuits operate independently to provide optimal cooling for both the laser and laser head.
  5. Shutdown: To turn off the chiller, press the main power switch. For extended periods of non-use, it is recommended to drain the water.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your chiller.

7. Troubleshooting

This section addresses common issues you might encounter. For problems not listed here, contact technical support.

ProblemPossible CauseSolution
Chiller not powering onNo power supply; power cord damaged; main switch offCheck power connection; inspect power cord; ensure main switch is on.
Water temperature too highInsufficient water; blocked condenser; ambient temperature too high; cooling fan malfunctionCheck water level and refill; clean condenser and filters; ensure adequate ventilation; check cooling fan operation.
Alarm activatedWater flow anomaly; over-temperature; sensor errorCheck water circulation; verify water level; consult digital controller manual for specific alarm codes.
Water leakageLoose connections; damaged hoses or sealsTighten all connections; inspect hoses and seals for damage and replace if necessary.

8. Specifications

Detailed technical specifications for the S&A CWFL-1500 Industrial Water Chiller.

ParameterValue
ModelCWFL-1500
VoltageAC 1P 220~240V
Frequency50Hz
Current3.4~20.3A
Power Consumption3.58kW
Electric Assisted Power0.55kW + 0.6kW
RefrigerantR-410a
Refrigerant Charge1100g
Temperature Precision±0.5℃
Temperature Control Range5°C ~ 35°C
ReducerCapillary
Pump Power0.55kW
Tank Capacity14 Liters
Inlet and OutletRp1/2" + Rp1/2"
Max. Pump Pressure4.4bar
Rated Flow2L/min + >15L/min
MaterialStainless Steel
Installation TypeStand-alone
ManufacturerSign-in-China

9. Warranty and Support

For warranty information, please refer to the documentation provided at the time of purchase. Warranty terms and conditions may vary.

For technical support, service, or spare parts, please contact the manufacturer, Sign-in-China, or your authorized distributor. Provide your product model (CWFL-1500) and serial number (if applicable) when seeking assistance.

You can also visit the Ving Store on Amazon for product information and potential support resources: Ving Store.

Related Documents - CWFL-1500

Preview S&A CWFL Series Industrial Chiller User Manual
User manual for the S&A CWFL series industrial chillers, covering models CWFL-500, CWFL-1000, CWFL-1500, CWFL-2000, and CWFL-3000. Provides information on overview, model illustration, parts, installation, operation, maintenance, and troubleshooting.
Preview CWFL-3000/4000/6000 Fiber Laser Special Chiller User Manual - S&A
User manual for the S&A CWFL-3000, CWFL-4000, and CWFL-6000 series fiber laser special chillers. Provides installation, operation, parameter adjustment, alarm, communication, and troubleshooting information for industrial use.
Preview CWFL-3000/4000/6000 Fiber Laser Special Chiller User Manual
This user manual provides detailed information on the S&A CWFL-3000, CWFL-4000, and CWFL-6000 series fiber laser special chillers. It covers installation procedures, unit introduction, parameter adjustments, alarm and communication outputs, MODBUS RS-485 communication functions, and simple troubleshooting steps. Designed for industrial use, these chillers are essential for maintaining optimal operating temperatures for laser systems.
Preview S&A CWFL-1000/1500/2000/3000 Industrial Chiller User Manual
Comprehensive user manual for S&A CWFL series industrial chillers (models 1000, 1500, 2000, 3000), covering installation, operation, maintenance, troubleshooting, and technical specifications.
Preview CWFL-800/1000/1500 Dual Temperature Industrial Chiller User Manual
User manual for the S&A CWFL-800, CWFL-1000, and CWFL-1500 Dual Temperature Industrial Chillers, covering installation, operation, parameters adjustment, specifications, and troubleshooting. Includes detailed instructions and safety precautions.
Preview CWFL-2000 Fiber Laser Special Chiller User Manual | S&A
Comprehensive user manual for the S&A CWFL-2000 Fiber Laser Special Chiller. Includes installation, operation, parameter adjustment, troubleshooting, and alarm information.