1. Introduction

Thank you for choosing the AERMEC SLG350W Inverter Air Conditioner. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new air conditioning system. Please read this manual thoroughly before using the appliance and keep it for future reference.

The AERMEC SLG350W is a 3.5 KW (12000 BTU) Inverter Split System Air Conditioner designed for optimal cooling and heating performance, utilizing R32 gas for improved environmental efficiency.

2. Safety Information

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.

3. Product Overview

The AERMEC SLG350W is a split-system air conditioner consisting of an indoor unit and an outdoor unit, connected by refrigerant piping and electrical wiring. It features inverter technology for energy efficiency and precise temperature control.

Aermec SLG350W Indoor and Outdoor Units with Remote Control

Figure 3.1: Overview of the Aermec SLG350W air conditioner system, showing the indoor unit, outdoor unit, and remote control. The indoor unit is a sleek white rectangular shape, and the outdoor unit is a compact, white rectangular box with a fan grille.

Aermec SLG350W Air Conditioner with R32 Gas and Inverter Logos

Figure 3.2: A closer view of the Aermec SLG350W air conditioner, highlighting its R32 refrigerant and Inverter technology. This image shows the indoor unit, outdoor unit, and remote control, with additional graphical icons indicating R32 gas, cooling/heating functions, monosplit system, and inverter technology.

Key Features:

4. Setup and Installation

Installation of the AERMEC SLG350W split system air conditioner requires specialized tools and knowledge. It is mandatory that installation be performed by a certified and qualified HVAC technician. Improper installation can lead to refrigerant leaks, electrical hazards, and damage to the unit, voiding the warranty.

4.1 Pre-Installation Checks

4.2 Indoor Unit Placement

4.3 Outdoor Unit Placement

4.4 Electrical Connections

All electrical wiring must comply with local codes and regulations. A dedicated circuit breaker is recommended.

4.5 Refrigerant Piping and Drainage

Proper vacuuming of the refrigerant lines is crucial before charging the system. Ensure the condensate drain line is sloped correctly to allow for continuous drainage.

5. Operating Instructions

Your AERMEC SLG350W air conditioner is operated primarily via the included remote control.

5.1 Remote Control Functions

The remote control allows you to adjust various settings:

5.2 Operating Modes

5.3 Wi-Fi Control (Optional)

If you have purchased and installed the optional WIFIKIT10, you can control your air conditioner remotely using a dedicated smartphone or tablet application. Refer to the Wi-Fi kit's separate instructions for setup and usage.

6. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always disconnect power before performing any maintenance.

6.1 Air Filter Cleaning (Indoor Unit)

The prefilter should be cleaned every two weeks or more frequently depending on usage and air quality.

  1. Open the front panel of the indoor unit.
  2. Remove the air filters.
  3. Clean the filters with a vacuum cleaner or wash them with lukewarm water (below 40°C).
  4. Allow the filters to dry completely in a shaded area before reinstalling.
  5. Close the front panel.

6.2 Outdoor Unit Cleaning

Periodically clean the outdoor unit's coil and fan blades to remove dust, leaves, and debris. This should ideally be done by a professional technician during annual servicing.

6.3 Seasonal Checks

7. Troubleshooting

Before contacting service, check the following common issues and solutions:

ProblemPossible CauseSolution
Unit does not startNo power; Remote control batteries low; Timer set.Check power supply/breaker; Replace batteries; Cancel timer setting.
Insufficient cooling/heatingDirty air filter; Obstruction at air inlet/outlet; Temperature setting incorrect; Room too large.Clean air filter; Remove obstruction; Adjust temperature; Consult technician for proper sizing.
Water leakage from indoor unitDrain hose clogged or kinked; Improper installation.Check and clear drain hose; Contact qualified technician for inspection.
Unusual noiseLoose parts; Fan obstruction; Compressor issue.Turn off unit and inspect for loose parts; Contact qualified technician.

If the problem persists after attempting these solutions, please contact a qualified service technician. Do not attempt to repair the unit yourself.

8. Specifications

Technical specifications for the AERMEC SLG350W Inverter Air Conditioner:

FeatureValue
Model NumberSLG350W
Cooling Capacity3.2 kW (12000 BTU)
Heating Capacity3.5 kW
Power Consumption (Cooling)1.0 kW
Power Consumption (Heating)1.0 kW
Energy Efficiency Class (Cooling)A++
Energy Efficiency Class (Heating)A+
SEER (Seasonal Energy Efficiency Ratio)6.1
SCOP (Seasonal Coefficient of Performance)4.0
Refrigerant TypeR32
Installation MethodSplit System
Special FeaturesInverter Compressor, Wi-Fi Ready (with optional kit)
Filter TypePrefilter

9. Warranty and Support

9.1 Warranty Information

The AERMEC SLG350W air conditioner comes with a limited warranty. Please refer to the warranty card included with your product for specific terms, conditions, and duration. Keep your purchase receipt as proof of purchase for warranty claims.

9.2 Customer Support

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact AERMEC customer support or your authorized dealer.

Please visit the official AERMEC website for the most up-to-date contact information and service center locations.

Related Documents - SLG350W

Preview AERMEC SLG Serie Installationshandbuch | Klimaanlagen Installation & Wartung
Umfassendes Installationshandbuch für AERMEC SLG Serie Split-Klimaanlagen (200W-700W). Enthält detaillierte Anleitungen zur Installation, Wartung, Fehlerbehebung und technische Daten für Modelle wie SLG200W, SLG250W, SLG350W, SLG500W, SLG700W.
Preview AERMEC FK260 FK360 Use and Installation Manual
Comprehensive guide for the installation, operation, and maintenance of AERMEC FK260 and FK360 air conditioning units, covering safety, features, technical specifications, and troubleshooting.
Preview AERMEC CMP231 Air Conditioner User Manual
Comprehensive user manual for the AERMEC CMP231 air conditioner, covering operation, warnings, troubleshooting, technical data, and maintenance procedures.
Preview AERMEC Remote Controller User Manual
Comprehensive user manual for the AERMEC remote controller, detailing all functions, operations, and settings for your air conditioning unit, including mode selection, fan speed, timers, and special features.
Preview AERMEC SRP Heat Pumps: Technical, Installation, and Maintenance Manual
Comprehensive guide for AERMEC SRP heat pumps, detailing technical specifications, installation procedures, operational limits, and maintenance guidelines for optimal performance and longevity. Covers models SRP 10, SRP 14M, SRP 14T, and SRP 19.
Preview Manuale Utente Telecomando AERMEC WLRC
Guida completa all'uso del telecomando AERMEC WLRC per condizionatori d'aria, con spiegazioni dettagliate delle funzioni, modalità operative, impostazioni e icone del display.