1. Introduction
This manual provides essential information for the safe and effective operation of your Airthereal MA10K-PRO Ozone Generator. Please read all instructions carefully before use to ensure proper function and to prevent potential hazards. The Airthereal MA10K-PRO is designed for high-capacity ozone output, suitable for treating areas up to 3500+ square feet, to assist in odor removal and air purification.
2. Important Safety Information
WARNING: Ozone is a powerful oxidant and can be harmful if inhaled. This device must only be used in unoccupied spaces. Failure to follow these safety instructions can result in serious injury or death.
- Use Only in Unoccupied Spaces: Ensure no humans, pets, or plants are present in the area during operation.
- Ventilation Required: After treatment, allow a minimum of 30 to 60 minutes for the ozone to dissipate before re-entering the treated space. Open windows and doors upon re-entry to facilitate ventilation.
- Industrial Use Only: This device is intended for industrial applications as defined by regulatory guidelines, such as odor and smoke control in hotels, mold/odor remediation, or vehicle reconditioning, always in unoccupied spaces by trained personnel.
- Electrical Safety: Do not operate the unit with a damaged cord or plug. Keep the unit dry and away from water.
- California Restriction: This product is not available for sale in California due to state regulations.
Always refer to local regulations and guidelines regarding ozone generator usage.
3. Product Overview and Components
The Airthereal MA10K-PRO Ozone Generator is a compact and portable unit designed for efficient air treatment.

Figure 3.1: Front view of the Airthereal MA10K-PRO Ozone Generator, showing the timer knob, power indicator, and ozone output grille.
3.1 Main Components
- Ozone Output Grille: Front panel where ozone is released.
- Timer Knob: Used to set the operation duration (0-120 minutes) or continuous 'HOLD' function.
- Power Indicator Light: Illuminates when the unit is operating.
- Rear Fan: Facilitates air intake and ozone distribution.
- Power Inlet: For connecting the power cord.
- Handle: For portability.

Figure 3.2: Rear view of the ozone generator, displaying the fan and power connection port.
3.2 What's Included
- Airthereal MA10K-PRO Ozone Generator
- Power Cord
- User Manual (this document)
- "NO ENTRY" Door Tag

Figure 3.3: The Airthereal MA10K-PRO unit along with its user manual and a safety door tag.
4. Setup
- Prepare the Area: Remove all humans, pets, and plants from the space to be treated.
- Close Openings: Close all windows and exterior doors to contain the ozone.
- Place the Generator: Position the Airthereal MA10K-PRO in a central location within the treatment area, ensuring the ozone output grille is unobstructed.
- Connect Power: Plug the power cord into the unit's power inlet, then into a standard electrical outlet.
- Display Safety Tag: Place the "NO ENTRY" door tag on the entrance to the treated area to warn others.
5. Operating Instructions
The Airthereal MA10K-PRO features a simple control knob for setting treatment duration.

Figure 5.1: The control knob for setting the operational timer or continuous 'HOLD' mode.
- Determine Treatment Time: Refer to the recommended operating times based on the area size and odor intensity. A 150 sq.ft. space can be treated in approximately 10 minutes.
- Set the Timer: Rotate the control knob clockwise to select the desired treatment duration (0-120 minutes). For continuous operation, turn the knob to the 'HOLD' position.
- Activate: Once the timer is set, the unit will begin operation, and the power indicator light will illuminate.
- Exit the Area: Immediately leave the treated space and ensure it remains unoccupied.
- Post-Treatment Ventilation: After the set time has elapsed and the unit has turned off, wait at least 30 to 60 minutes before re-entering. Upon re-entry, open windows and doors to ventilate the area thoroughly.
5.1 Recommended Operating Time
The following table provides general guidelines for treatment duration based on room size. Actual times may vary depending on odor severity and room conditions.

Figure 5.2: Recommended operating times for various room sizes.
| Square Footage | Recommended Time |
|---|---|
| 200 sq ft | 10 minutes |
| 300 sq ft | 15 minutes |
| 500 sq ft | 30 minutes |
| 700 sq ft | 45 minutes |
| 1000 sq ft | 60 minutes |
| 1500 sq ft | 90 minutes |
| 2000+ sq ft | HOLD (Continuous) |
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your ozone generator.
6.1 Ozone Plate Cleaning and Replacement
The MA10K-PRO features an upgraded honeycomb ozone plate designed for a long service life of approximately 20,000 hours.

Figure 6.1: The long-lasting honeycomb ozone plate, responsible for ozone generation.
- Cleaning: Over time, dust and debris may accumulate on the ozone plate, reducing efficiency. Periodically, with the unit unplugged, carefully remove the ozone plate (refer to specific instructions in the full manual for removal) and clean it with a dry brush or a vacuum cleaner. Do not use water or liquid cleaners.
- Replacement: When ozone output significantly decreases, or after approximately 20,000 hours of use, the ozone plate may need replacement. Contact Airthereal customer service for replacement parts and detailed instructions.
6.2 Fan Cleaning
Ensure the rear fan grille remains clear of obstructions to maintain proper airflow. With the unit unplugged, use a soft brush or vacuum to remove any dust from the fan grille.

Figure 6.2: Internal view highlighting the fan, which provides 40% larger airflow for wider ozone distribution.
7. Troubleshooting
If you encounter issues with your Airthereal MA10K-PRO, refer to the following common troubleshooting steps:
- Unit Not Turning On:
- Ensure the power cord is securely plugged into both the unit and a working electrical outlet.
- Check if the timer knob is set to a duration or 'HOLD' position.
- Verify the power outlet is functional by plugging in another device.
- Low Ozone Output:
- The ozone plate may be dirty. Refer to Section 6.1 for cleaning instructions.
- The ozone plate may have reached the end of its service life and requires replacement.
- Ensure the fan grille is not obstructed, allowing for proper airflow.
- Unusual Noises:
- A slight sizzling sound and dim blue-purple glow are normal during operation, indicating corona discharge.
- If loud or grinding noises occur, unplug the unit immediately and contact customer support.
For issues not resolved by these steps, please contact Airthereal customer support.
8. Specifications
Technical specifications for the Airthereal MA10K-PRO Ozone Generator:
| Specification | Value |
|---|---|
| Model | MA10K-PRO |
| Power Supply | AC 110V / 60Hz (for USA and Canada) |
| Power Consumption | 110W |
| Ozone Production | 10,000mg/h |
| Air Flow Volume | 100 CFM |
| Noise Level | < 45 Decibels |
| Timer | 0-120 minutes / HOLD |
| Product Dimensions | 7.1"D x 9.3"W x 6.8"H (180 x 237 x 175 mm) |
| Weight | 6.6 lbs (3 kg) |
| Application Area | Up to 3500+ sq ft |
| Ozone Plate Lifespan | 20,000 hours |
9. Warranty and Support
Airthereal is a US brand established in 2018, committed to providing quality air purification solutions. For warranty information, technical assistance, or replacement parts, please contact our dedicated stateside customer service team. Refer to the official Airthereal website or the product packaging for current contact details.