Red Lion PAXD0000

Red Lion Controls/N-Tron PAXD0000 Universal DC Input Meter User Manual

Model: PAXD0000

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Red Lion Controls/N-Tron PAXD0000 Universal DC Input Meter. Please read this manual thoroughly before using the device and retain it for future reference.

The PAXD0000 is designed for universal DC input measurement applications, offering reliable performance in industrial environments.

2. Safety Information

Always observe standard safety precautions during installation and operation. Failure to comply with safety warnings may result in injury or damage to the equipment.

  • Ensure power is disconnected before performing any wiring or maintenance.
  • Installation and servicing should only be performed by qualified personnel.
  • Do not operate the device in environments exceeding its specified operating conditions.
  • Protect the device from moisture, dust, and extreme temperatures.

3. Product Overview

The Red Lion PAXD0000 Universal DC Input Meter features a clear digital display and intuitive control buttons for easy configuration and monitoring.

Front view of the Red Lion PAXD0000 Universal DC Input Meter display and control buttons.

Figure 1: Front panel of the PAXD0000 meter. This image shows the front panel of the PAXD0000 meter, featuring a red digital display showing '67.4 %' and five control buttons labeled DSP, PAR, F1, F2, and RST.

Front Panel Components:

  • Digital Display: High-visibility red LED display for showing measured values and menu parameters.
  • DSP Button: Used for display functions and navigating through display modes.
  • PAR Button: Used for accessing and setting parameter configurations.
  • F1 Button: Function button 1, typically for specific user-defined actions or menu navigation.
  • F2 Button: Function button 2, typically for specific user-defined actions or menu navigation.
  • RST Button: Reset button, used for resetting values or confirming selections.

4. Setup

4.1. Installation

The PAXD0000 is designed for panel mounting. Ensure adequate space for ventilation and wiring connections.

  1. Cut a panel cutout of the specified dimensions (refer to the product datasheet for exact measurements).
  2. Insert the meter into the cutout from the front.
  3. Secure the meter using the provided mounting clips from the rear of the panel.

4.2. Wiring

Refer to the wiring diagram provided with your device for specific terminal connections. Ensure all connections are secure and correctly polarized.

  • Power Supply: Connect the appropriate DC power supply to the designated power terminals. Verify voltage compatibility.
  • Input Signal: Connect the DC input signal to the input terminals. Observe polarity for accurate readings.
  • Output Connections (if applicable): If your model includes output options (e.g., relays, analog output), connect them according to your system requirements.

4.3. Powering On

Once all wiring is complete and verified, apply power to the device. The display should illuminate, and the meter will perform a self-test before showing the measured value.

5. Operating Instructions

5.1. Basic Measurement Display

Upon power-up, the meter will typically display the primary measured DC input value. Use the DSP button to cycle through various display modes, such as minimum, maximum, or other configured values.

5.2. Parameter Configuration

To access and modify device parameters:

  1. Press the PAR button to enter the parameter menu.
  2. Use the F1 and F2 buttons to navigate through the parameters.
  3. Press RST to select a parameter for editing.
  4. Use F1 and F2 to change the parameter value.
  5. Press RST again to confirm the new value and save it.
  6. Press PAR to exit the parameter menu.

Common parameters include input scaling, decimal point position, and alarm setpoints. Refer to the detailed programming guide for a complete list of parameters and their functions.

6. Maintenance

6.1. Cleaning

Clean the front panel with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these may damage the display or housing.

6.2. Calibration

The PAXD0000 is factory calibrated. If recalibration is required, refer to the advanced programming manual or contact Red Lion technical support. Recalibration should only be performed by trained personnel using certified equipment.

7. Troubleshooting

This section provides solutions to common issues. For problems not listed here, contact technical support.

Problem Possible Cause Solution
Display is blank No power, incorrect wiring, or power supply failure. Check power connections and supply voltage. Verify wiring against the diagram.
Incorrect readings Incorrect input wiring, scaling errors, or sensor issue. Verify input wiring polarity. Check parameter settings for scaling. Test input signal with a known source.
Buttons unresponsive Temporary software glitch or physical damage. Cycle power to the device. If problem persists, contact support.

8. Specifications

Feature Detail
Model PAXD0000
Brand Red Lion
Manufacturer Red Lion Controls
Input Type Universal DC Input
ASIN B07CZLSTMV
UPC 747356317894
Date First Available May 10, 2018

For complete technical specifications, refer to the official product datasheet available on the Red Lion website.

9. Warranty Information

Red Lion Controls products are typically covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please refer to the official Red Lion Controls warranty statement available on their website or contact your local distributor for detailed information.

Retain your proof of purchase for warranty claims.

10. Support

For technical assistance, troubleshooting, or further information regarding the PAXD0000 Universal DC Input Meter, please contact Red Lion Controls technical support.

You can also visit the official Red Lion website for product documentation, FAQs, and contact details. For general inquiries or to explore other products, visit the Red Lion Store on Amazon.

Related Documents - PAXD0000

Preview Red Lion PAX Series 1/8 DIN Analog Input Panel Meters - User Manual
Comprehensive user manual for the Red Lion PAX Series 1/8 DIN Analog Input Panel Meters, covering specifications, installation, wiring, programming, troubleshooting, and option cards for models PAXD, PAXP, PAXS, PAXT, and PAXH.
Preview Red Lion CUB5P Miniature Electronic 5-Digit Process Meter User Manual
Detailed user manual for the Red Lion CUB5P Miniature Electronic 5-Digit Process Meter, covering installation, wiring, programming, and specifications. Learn about its features, options, and operation.
Preview Red Lion CUB5 Miniature Electronic 8-Digit Dual Counter and Rate Indicator
Detailed specifications, installation guide, and programming manual for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Features include selectable LCD or LED backlighting, optional relay and serial communication modules, and NEMA 4X/IP65 sealing.
Preview Red Lion CUB®5 Miniature Electronic 8-Digit Dual Counter and Rate Indicator Manual
Comprehensive user manual for the Red Lion CUB®5, detailing its features as a miniature electronic 8-digit dual counter and rate indicator, including installation, programming, and communication options for industrial applications.
Preview Red Lion Technical Reference Catalog: Indication Products
Explore the comprehensive Red Lion Technical Reference Catalog, detailing a wide array of industrial indication products including panel meters, timers, counters, temperature controls, signal conditioners, tachometers, and sensors. Discover solutions for automation and control.
Preview Red Lion CL01 Paradigm 2x20 LCD Operator Interface Terminal Manual
Technical manual and specifications for the Red Lion CL01 Paradigm 2x20 LCD Operator Interface Terminal, covering features, installation, safety, and troubleshooting.