1. Introduction

This manual provides detailed instructions for the proper installation, operation, and maintenance of the RectorSeal Dura G-O-N 82763 3-inch Nozzle and Escutcheon. The Dura G-O-N is designed to effectively divert water away from building foundations, reducing the risk of moisture-related damage.

2. Safety Information

Always observe basic safety precautions during installation and maintenance. Wear appropriate personal protective equipment (PPE) such as safety glasses and gloves. Ensure the work area is clear of obstructions. If you are unsure about any step, consult a qualified plumbing professional.

3. Components

The RectorSeal Dura G-O-N 82763 package includes the following:

  • Dura G-O-N Nozzle (3-inch)
  • Escutcheon with Security Ring
RectorSeal Dura G-O-N 82763 Nozzle and Escutcheon, top-down view

Figure 1: Top-down view of the Dura G-O-N Nozzle and Escutcheon.

Front view of the RectorSeal Dura G-O-N 82763 Nozzle and Escutcheon

Figure 2: Front view of the Dura G-O-N Nozzle and Escutcheon.

4. Setup and Installation

The Dura G-O-N nozzle is designed for direct installation onto PVC drain pipe. Its marine-grade ASA polymer construction with a bonded, threaded, and sealed PVC insert allows for quick and secure gluing.

  1. Prepare the PVC Pipe: Ensure the end of the PVC drain pipe is clean, dry, and free of burrs.
  2. Apply PVC Cement: Apply a suitable PVC cement to the exterior of the PVC drain pipe and the interior of the Dura G-O-N nozzle's PVC insert. Follow the cement manufacturer's instructions for application and curing times.
  3. Attach the Nozzle: Firmly push the Dura G-O-N nozzle onto the PVC drain pipe, twisting slightly to ensure even distribution of cement and a secure bond. Hold in place for the recommended time.
  4. Install the Escutcheon: Position the escutcheon against the wall, aligning it with the nozzle. The escutcheon is furnished with a security ring for enhanced attachment. Secure the escutcheon to the wall using appropriate fasteners (not included) through the pre-drilled holes.
  5. Curing Time: Allow the PVC cement to cure completely before water is introduced to the system, as per the cement manufacturer's guidelines.

Installation Video Resources

Video 1: Overview of RectorSeal Dura G-O-N Nozzle & Escutcheon. This video demonstrates the product's features and benefits in diverting water from foundations.

Video 2: RectorSeal 3" Dura G-O-N Product Demonstration. This video provides a closer look at the 3-inch Dura G-O-N model, highlighting its design and function.

5. Operating Instructions

The RectorSeal Dura G-O-N is a passive drainage component. Once properly installed, it operates by directing water flow from the downspout away from the building's foundation. No manual operation is required.

6. Maintenance

Regular maintenance ensures optimal performance and longevity of your Dura G-O-N nozzle and escutcheon.

  • Periodic Inspection: Periodically check the nozzle and escutcheon for any signs of damage, cracks, or loose connections.
  • Cleaning: Clear any debris, leaves, or other obstructions from the nozzle opening and the surrounding area to ensure unimpeded water flow. The optional bird screen (if installed) should also be checked and cleaned.
  • Foundation Check: Regularly inspect the area around the foundation to confirm that water is being effectively diverted and no pooling occurs.

7. Troubleshooting

If you encounter issues with your Dura G-O-N, consider the following:

  • Water Pooling Near Foundation: Check for blockages within the nozzle or the connecting PVC pipe. Ensure the ground around the foundation slopes away from the building to facilitate proper drainage.
  • Loose Escutcheon: Re-tighten or replace fasteners securing the escutcheon to the wall.
  • Damaged Components: If any part of the nozzle or escutcheon is cracked or broken, replacement may be necessary.

8. Specifications

FeatureDetail
Model Number82763
MaterialMarine Grade ASA Polymer
Inlet Connection Size3 Inches
Inlet Connection TypePVC (bonded, threaded, sealed insert)
Outlet Connection Size3 Inches
Exterior FinishBronze
Dimensions (L x W x H)9 x 9 x 6 inches
Item Weight1.2 pounds
Included ComponentsGlue On Nozzle, Escutcheon

9. Warranty and Support

For warranty information or technical support regarding your RectorSeal Dura G-O-N 82763 Nozzle and Escutcheon, please contact RectorSeal customer service directly. Refer to the official RectorSeal website or product packaging for current contact details.

Related Documents - 82763

Preview RSH-50 Surge Protection Device Installation Instructions and Warranty
Installation instructions and warranty information for the RectorSeal RSH-50 Surge Protection Device with Non-Fused Disconnect Box 120/240 VAC, 60A. Includes product details, wiring diagrams, safety notices, and warranty coverage.
Preview Rectorseal No. 5 Premium Multi-Purpose Pipe Thread Sealant Safety Data Sheet
Safety Data Sheet for Rectorseal No. 5, a premium multi-purpose pipe thread sealant. Provides information on hazards, first aid, handling, storage, and disposal.
Preview RectorSeal AquaGuard AG-1200+ Installation Instructions
Detailed installation instructions for the RectorSeal AquaGuard AG-1200+ magnetic float switch, including safety precautions, mounting, and wiring diagrams for conventional and communicating HVAC systems.
Preview RectorSeal AG-9100 AquaGuard Remote Alarm Installation and Warranty Guide
Comprehensive installation instructions, wiring diagrams, safety guidelines, and limited warranty information for the RectorSeal AG-9100 AquaGuard Remote Alarm system. Learn how to properly mount, wire, and test your AG-9100 alarm.
Preview RectorSeal Outset Seal Installation Guide and Product Information
Detailed guide for installing the RectorSeal Outset Seal, a solution for protecting indoor areas from air leakage, moisture, and rodent intrusion where HVAC linesets exit structures. Includes parts list and step-by-step instructions.
Preview RectorSeal AquaGuard AG-1200+ Installation Instructions
Detailed installation and wiring instructions for the RectorSeal AquaGuard AG-1200+ magnetic float switch, designed for HVAC systems. Includes safety warnings, step-by-step guides for drain pan mounting and electrical connections in both conventional and communicating HVAC systems.