Moxa EDS-308-SS-SC

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Moxa EDS-308-SS-SC Unmanaged Industrial Ethernet Switch User Manual

1. Introduction

This manual provides essential instructions for the installation, operation, and maintenance of the Moxa EDS-308-SS-SC Unmanaged Industrial Ethernet Switch. To ensure safe and efficient use, please read this manual thoroughly before operating the device. Keep this manual for future reference.

2. Product Overview

2.1 Key Features

  • Unmanaged Industrial Ethernet Switch: Designed for plug-and-play operation without complex configuration.
  • Port Configuration: 6 x 10/100BaseTX Ethernet ports (RJ45) and 2 x 100BaseFX single-mode SC fiber ports.
  • Fiber Optic Connectivity: Single-mode fiber for extended distance communication.
  • Smart Relay Output Alarm: Provides an alarm contact for event notification, such as power failure or port link down.
  • Industrial Design: Rugged housing, wide operating temperature range, and redundant power inputs for reliable operation in harsh industrial environments.

2.2 Package Contents

Before installation, verify that the package contains the following items:

  • Moxa EDS-308-SS-SC Industrial Ethernet Switch
  • Terminal block for power input and relay output
  • Quick Installation Guide
  • Warranty Card

If any of these items are missing or damaged, please contact your sales representative immediately.

3. Hardware Description

3.1 Front Panel Layout

The front panel of the EDS-308-SS-SC switch features the Ethernet ports, fiber ports, LED indicators, and the model number label.

Front view of Moxa EDS-308-SS-SC Industrial Ethernet Switch

Figure 1: Front view of the Moxa EDS-308-SS-SC switch, showing the 6 RJ45 Ethernet ports (1-6), 2 SC fiber ports (7-8), and LED indicators for power and fault status.

3.2 Port Description

  • 10/100BaseTX Ports (RJ45): Ports 1 to 6 are 10/100 Mbps auto-sensing Ethernet ports with auto MDI/MDI-X function. These ports automatically detect the speed and duplex mode of the connected device and adjust accordingly.
  • 100BaseFX Ports (SC, Single Mode): Ports 7 and 8 are 100 Mbps fiber optic ports using SC connectors. These ports support single-mode fiber for long-distance communication.

3.3 LED Indicators

The EDS-308-SS-SC features several LED indicators to provide status information:

  • PWR1 (Green): Illuminates when power input 1 is active.
  • PWR2 (Green): Illuminates when power input 2 is active.
  • FAULT (Red): Illuminates when a power failure or a port link failure occurs.
  • Link/Act (Green, per port): Illuminates when a valid network link is established. Blinks when data is being transmitted or received.

3.4 Power Input and Relay Output Terminal Block

The device uses a removable terminal block for power input and relay output connections. This block is typically located on the top panel.

Angled view of Moxa EDS-308-SS-SC Industrial Ethernet Switch showing terminal block

Figure 2: Angled view of the Moxa EDS-308-SS-SC, highlighting the terminal block for power and relay output at the top, and the various ports on the front panel.

  • Power Input: Supports redundant dual DC power inputs (PWR1, PWR2) for enhanced reliability.
  • Relay Output: A single relay output for alarm events.

4. Installation and Setup

4.1 Safety Precautions

  • Ensure power is disconnected before installation or wiring.
  • Install the device in a well-ventilated area.
  • Properly ground the device to prevent electrical hazards and ensure stable operation.

4.2 Mounting Options

The EDS-308-SS-SC can be mounted on a DIN-rail or directly to a wall.

4.2.1 DIN-Rail Mounting

  1. Attach the DIN-rail mounting kit (if not pre-installed) to the rear panel of the switch.
  2. Hook the top of the DIN-rail clip over the top edge of the DIN-rail.
  3. Press the switch firmly against the DIN-rail until it snaps into place.

4.2.2 Wall Mounting

  1. Remove the DIN-rail attachment plate from the switch.
  2. Use screws to secure the wall mounting plate (if provided) to the switch.
  3. Mount the switch to a wall or cabinet surface using appropriate screws.

4.3 Wiring the Power Input

The EDS-308-SS-SC supports redundant 12/24/48 VDC power inputs. Connect the power sources to the PWR1 and PWR2 terminals on the terminal block. Ensure correct polarity.

  • PWR1: Connect the positive (+) and negative (-) wires of the first DC power source.
  • PWR2: Connect the positive (+) and negative (-) wires of the second DC power source (optional, for redundancy).

4.4 Wiring the Relay Output

The relay output provides a dry contact for alarm signaling. Connect external alarm devices (e.g., warning lights, buzzers) to the relay output terminals on the terminal block. The relay will activate (close or open, depending on configuration) when a fault condition is detected.

4.5 Grounding the Switch

Connect the grounding wire from the grounding screw on the switch to a proper earth ground. This is crucial for electrical safety and to protect the device from electromagnetic interference (EMI).

4.6 Network Connection

4.6.1 Ethernet (RJ45) Ports

Connect standard Cat5e or better Ethernet cables from your network devices (e.g., PCs, PLCs, other switches) to the RJ45 ports (1-6) on the EDS-308-SS-SC. The auto MDI/MDI-X function eliminates the need for crossover cables.

4.6.2 Fiber Optic (SC) Ports

Connect single-mode fiber optic cables with SC connectors to ports 7 and 8. Ensure that the transmit (TX) fiber from one device connects to the receive (RX) port of the other device, and vice-versa.

5. Operating Instructions

5.1 Powering On

After all connections are securely made, apply power to the switch. The PWR1 and/or PWR2 LEDs should illuminate green, indicating successful power-up.

5.2 Checking Network Connectivity

Once network devices are connected to the switch, observe the Link/Act LEDs for each port:

  • A solid green Link/Act LED indicates a successful network link.
  • A blinking green Link/Act LED indicates active data transmission or reception.
  • If the Link/Act LED is off, check the cable connection and the status of the connected device.

5.3 Alarm Functionality

The FAULT LED will illuminate red and the relay output will activate if a power failure (both PWR1 and PWR2 off) or a port link failure (any connected port loses link) occurs. This provides immediate notification of critical events.

6. Maintenance

6.1 General Care

  • Keep the switch clean and free from dust and debris.
  • Ensure adequate ventilation around the device to prevent overheating.
  • Avoid exposing the switch to extreme temperatures, humidity, or corrosive environments beyond its specified operating conditions.

6.2 Cleaning

Use a soft, dry cloth to clean the exterior of the switch. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device. Do not use abrasive cleaners or solvents.

6.3 Fiber Optic Port Cleaning

Regularly inspect and clean fiber optic connectors to ensure optimal performance. Use specialized fiber optic cleaning tools and procedures to avoid damaging the delicate fiber ends.

7. Troubleshooting

This section provides solutions to common issues you might encounter with the EDS-308-SS-SC switch.

ProblemPossible CauseSolution
No Power (PWR LEDs off)
  • No power supply connected.
  • Faulty power supply.
  • Incorrect wiring.
  • Verify power supply connection.
  • Check power supply functionality.
  • Ensure correct polarity and secure wiring to the terminal block.
No Link (Link/Act LED off)
  • Faulty or disconnected network cable.
  • Connected device is off or faulty.
  • Incorrect fiber connection (TX/RX swapped).
  • Check and re-seat network cables. Try a different cable.
  • Verify the connected device is powered on and functioning.
  • For fiber, ensure TX connects to RX and vice-versa. Clean fiber connectors.
FAULT LED is Red
  • Power failure (both PWR1 and PWR2 off).
  • Port link failure on one or more ports.
  • Check power supplies and connections.
  • Inspect all connected network cables and devices for link status.
Network Communication Issues
  • IP address conflicts (if devices are configured statically).
  • Excessive network traffic.
  • Faulty network interface card (NIC) on connected device.
  • Verify IP configurations of connected devices.
  • Monitor network traffic.
  • Test with a different network device.

8. Specifications

ModelEDS-308-SS-SC
Ethernet Ports6 x 10/100BaseTX (RJ45, Auto MDI/MDI-X)
Fiber Optic Ports2 x 100BaseFX (SC Connector, Single Mode)
Input Voltage12/24/48 VDC (Redundant Dual Inputs)
Power ConsumptionMax. 4.8 W @ 24 VDC (Typical)
Alarm Contact1 Relay Output, 1A @ 24 VDC
Operating Temperature-40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Relative Humidity5 to 95% (non-condensing)
HousingIP30 Aluminum Alloy
Dimensions (W x H x D)53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
MountingDIN-rail, Wall Mount
StandardsIEEE 802.3, 802.3u, 802.3x
UPC747356312011

9. Warranty and Support

Moxa products are backed by a standard warranty. For detailed warranty information, terms, and conditions, please refer to the official Moxa website or the warranty card included with your product.

For technical support, product documentation, or to report issues, please visit the Moxa support portal or contact your local authorized Moxa distributor. Ensure you have your product model number (EDS-308-SS-SC) and serial number ready when seeking support.

© 2023 Moxa Inc. All rights reserved. Information is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.