1. Important Safety Information
Please read this manual thoroughly before installing, operating, or performing maintenance on your Cata GL 45 X range hood. Keep this manual for future reference. Failure to follow these instructions could result in electric shock, fire, or injury.
- Ensure the electrical installation complies with local regulations and is performed by a qualified electrician.
- Always disconnect the appliance from the power supply before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Do not flambé under the range hood.
- Ensure adequate ventilation in the room when the range hood is used simultaneously with appliances burning gas or other fuels.
- The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
2. Setup and Installation
2.1 Unpacking
Carefully remove the range hood from its packaging. Inspect the appliance for any damage. Keep packaging materials away from children.
2.2 Location and Mounting
The Cata GL 45 X is an integrated kitchen hood designed for under-cabinet mounting. Ensure sufficient clearance above your cooking surface as per local safety regulations. The hood features an easy installation system.

Image: Cata GL 45 X Range Hood installed under a kitchen cabinet, showing its integrated design.
2.3 Dimensions
Refer to the diagram below for precise dimensions to ensure proper fit and installation.

Image: Technical drawing illustrating the dimensions of the Cata GL 45 X Range Hood.
2.4 Electrical Connection
The appliance operates on 220 Volts. Ensure the power supply is compatible. It is recommended that a qualified technician performs the electrical connection.
2.5 Ventilation Options
The hood supports both ducted and recirculation (ductless) ventilation. The discharge diameter is 150/125 mm for ducted installations. For recirculation, ensure active carbon filters are installed.
3. Operating Instructions
The Cata GL 45 X features a touch control panel for easy operation.

Image: Close-up view of the touch control panel with power level indicators and light controls.
3.1 Power Levels
The hood offers 4 extraction speeds: 3 standard levels and 1 Turbo level. Adjust the power according to the intensity of cooking fumes and odors.
- Level 1-3: For light to moderate cooking.
- Turbo Level: For intense cooking or strong odors, providing maximum extraction capacity of 820 m³/h.
3.2 LED Lighting
The integrated high-efficiency LED lights are adjustable in intensity, providing illumination for your cooking area.
3.3 Automatic Shut-off Timer
Utilize the automatic shut-off timer function to program the hood to continue operating for a set period after cooking, ensuring complete removal of residual fumes and odors.
3.4 Usage Recommendations
- Turn on the hood approximately 5 minutes before you begin cooking to establish an airflow.
- Use cooking zones closest to the wall to optimize fume capture.
- Avoid drafts during cooking, as this can interfere with the hood's effectiveness.
- Cover boiling pots and pans to reduce steam production.
- After cooking, keep the hood running for at least 5 to 15 minutes, depending on the intensity of fumes and odors generated.
4. Maintenance
4.1 Cleaning Metal Filters
The metal grease filters are dishwasher-safe and should be cleaned periodically to maintain optimal performance. The hood features a filter cleaning indicator to remind you when cleaning is due.

Image: View of the metal grease filters, designed for easy removal and cleaning.
4.2 Replacing Charcoal Filters (Recirculation Mode)
If your hood is operating in recirculation mode, the active charcoal filters (included) must be replaced regularly, typically every 3-6 months depending on usage. Refer to the specific instructions provided with the charcoal filters for replacement procedures.
4.3 Exterior Cleaning
Clean the stainless steel exterior with a soft cloth and a mild, non-abrasive cleaner. Avoid using harsh chemicals or abrasive materials that could damage the finish.
5. Troubleshooting
If you encounter issues with your Cata GL 45 X range hood, consult the following table before contacting customer service.
| Problem | Possible Cause | Solution |
|---|---|---|
| Low suction power | Clogged grease filters Improper ducting Obstruction in air outlet | Clean or replace grease filters Check ducting for bends or blockages Remove any obstructions |
| Excessive noise | Loose components Improper installation Ducting issues | Check for and tighten any loose parts Ensure secure mounting Inspect ducting for proper size and smooth path |
| Lights not working | Power supply issue Faulty LED module | Check power connection and circuit breaker Contact service for LED replacement |
| Control panel unresponsive | Power supply issue Panel dirty or wet | Check power connection Clean and dry the control panel thoroughly |
If the problem persists after attempting these solutions, please contact CATA customer support.
6. Specifications
Key technical specifications for the Cata GL 45 X Range Hood:
| Feature | Specification |
|---|---|
| Model Number | GL-45 X |
| Voltage | 220 Volts |
| Power | 280 Watts |
| Number of Speeds | 4 (3 + 1 Turbo) |
| Airflow Capacity | 820 m³/h (maximum) |
| Sound Level | 50 Decibels (minimum) |
| Dimensions (L x W x H) | 27.7 x 49.2 x 28 cm |
| Item Weight | 15 Kilograms |
| Energy Efficiency Class | A |
| Annual Energy Consumption | 58 kWh/year |
| Light Source Type | LED |
| Filter Type | Mesh (Dishwasher-safe metal filters) |
| Ventilation Type | Ductless/Recirculation |
| Material | Stainless steel |
| Controls Type | Touch |
Energy Label Information:

Image: EU Energy Label for the Cata GL 45 X Range Hood, indicating Class A energy efficiency and other performance metrics.
7. Warranty and Support
CATA products are manufactured using high-quality components and advanced techniques. For warranty information, please refer to the documentation provided at the time of purchase or visit the official CATA website. For technical support, spare parts, or service inquiries, please contact your local CATA service center or the retailer from whom you purchased the product.