1. Introduction
This manual provides essential instructions for the safe and effective operation, installation, and maintenance of the Winters DPG Series Digital Pressure Gauge. This device is designed for accurate pressure measurement across various industrial and scientific applications, with a range of 0 to 10000 PSI or -1 to +700 Bar. Please read this manual thoroughly before using the product.

Figure 1: Winters DPG Series Digital Pressure Gauge, displaying a pressure reading of 0.5.
2. Product Overview
The Winters DPG Series Digital Pressure Gauge offers precise digital pressure readings. Key features include a clear digital display, user-friendly controls, and robust construction suitable for demanding environments. It is available for various pressure ranges, including the 0 to 10000 PSI model.
- High Accuracy: Provides reliable pressure measurements.
- Wide Range: Supports pressure measurements from 0 to 10000 PSI.
- Durable Construction: Made with Acrylonitrile Butadiene Styrene (ABS) and Rubber for the casing, and 304SS Stainless Steel for the pressure connection.
- Digital Display: Easy-to-read digital readout.

Figure 2: The digital pressure gauge showing a zero reading, highlighting its accuracy of +/- 0.5%.

Figure 3: Examples of typical applications for the DPG Series gauge, such as air pressure systems, pharmaceutical manufacturing, food processing, and the automotive industry.
3. Setup and Installation
Proper installation is crucial for accurate readings and safe operation. Ensure the gauge is securely connected to the pressure source.
- Inspect the Gauge: Before installation, visually inspect the gauge for any signs of damage.
- Prepare Connection Point: Ensure the pressure connection point is clean and free of debris.
- Connect the Gauge: The DPG Series features a 1/4" NPT 304SS Stainless Steel connection. Carefully thread the gauge into the pressure port. Use appropriate sealing tape or compound if necessary, ensuring it does not obstruct the pressure port.
- Tighten Securely: Hand-tighten the gauge first, then use a wrench to tighten it securely. Do not overtighten, as this can damage the threads or the gauge.
- Verify Orientation: Ensure the gauge display is oriented for easy viewing.

Figure 4: Detail of the 1/4" NPT 304SS Stainless Steel connection, designed for secure and durable installation.

Figure 5: A closer view of the threaded connection, emphasizing the quality of the stainless steel material.
4. Operation
The DPG Series gauge features intuitive controls for power management and unit selection.

Figure 6: An annotated diagram detailing the functions of the Power and Menu buttons on the gauge.
4.1 Power Button
- Press: Turns the gauge ON for 1 minute. The backlight will stay on for 10 seconds. After 1 minute, the gauge turns OFF.
- Displays Battery Reading: The battery level is displayed during power ON.
- Tap: Turns the backlight back on for 10 seconds.
- Automatic Backlight: The backlight automatically activates when pressure changes by +10% of the scale (when the gauge is ON).
4.2 Menu Button
- Press: Changes pressure units. Available units include psi, mH2O, mbar, kPa (≤ 100 psi), psi, bar, Kg/cm², and MPa (2 160 psi).
4.3 General Functions Summary

Figure 7: A table providing a concise summary of the gauge's functions and their descriptions.
| Function | Description |
|---|---|
| ON/OFF | Long press to power on, or power off. |
| UNIT | Short press to change pressure units circularly. |
| BACK LIGHT | Short press, the back-light will light on for 10 seconds. |
| DISPLAY DIGITS | 4 Digits up to 5000 psi, 5 Digits for 10000 psi. |
| OPERATING/STORAGE TEMPERATURE | Operating: 14°F to 122°F (-10°C TO 50°C) Storage: -4°F to 167°F (-20°C TO 75°C) |
5. Maintenance
Regular maintenance ensures the longevity and accuracy of your digital pressure gauge.
- Cleaning: Wipe the gauge exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Battery Replacement: When the battery indicator shows low power, replace the batteries promptly to ensure continuous operation. Refer to the product specifications for battery type.
- Storage: Store the gauge in a clean, dry environment within the specified storage temperature range (-4°F to 167°F / -20°C to 75°C) when not in use.
- Calibration: For critical applications, periodic calibration by a certified laboratory is recommended to maintain accuracy. The product comes with a calibration certificate with traceability.
6. Troubleshooting
If you encounter issues with your DPG Series Digital Pressure Gauge, refer to the following common problems and solutions:
- Gauge Not Turning On:
- Check battery level. Replace batteries if low.
- Ensure the power button is pressed for a sufficient duration (long press for ON/OFF).
- Inaccurate Readings:
- Verify the gauge is properly installed and sealed to the pressure source.
- Ensure the operating temperature is within the specified range.
- Consider recalibration if accuracy issues persist, especially after prolonged use or exposure to extreme conditions.
- Display Not Visible / Backlight Issue:
- Tap the power button to activate the backlight for 10 seconds.
- Check battery level.
For issues not covered here, please contact customer support.
7. Specifications
| Attribute | Detail |
|---|---|
| Brand | Winters Instruments |
| Model Number | DPG Series |
| Pressure Range | 0 to 10000 PSI (or -1 to +700 Bar) |
| Accuracy | +/- 0.5% (as indicated in product images) |
| Connection Type | 1/4" NPT 304SS Stainless Steel |
| Material | Acrylonitrile Butadiene Styrene (ABS), Rubber (casing) |
| Item Weight | 14.08 ounces |
| Operating Temperature | 14°F to 122°F (-10°C to 50°C) |
| Storage Temperature | -4°F to 167°F (-20°C to 75°C) |
| Display Digits | 4 Digits (up to 5000 psi), 5 Digits (for 10000 psi) |
8. Warranty and Support
For warranty information, technical support, or service inquiries regarding your Winters DPG Series Digital Pressure Gauge, please contact Winters Instruments directly or refer to their official website.
You can also visit the Winters Instruments Store on Amazon for additional product information and support resources.
Please retain your purchase receipt and calibration certificate for warranty claims and service.