Introduction
This instruction manual provides essential information for the safe and effective use of ReliOn 30 Gauge Ultra-Thin Lancets. These lancets are designed for blood sampling to monitor blood glucose levels. Please read this manual thoroughly before use and retain it for future reference.
Important Safety Information
- Single Use Only: Lancets are for single use only. Reusing a lancet can cause infection and dull the tip, leading to increased pain.
- Do Not Share: Never share lancets or lancing devices with other individuals. This can transmit bloodborne pathogens.
- Proper Disposal: Always dispose of used lancets in an approved sharps container immediately after use.
- Keep Out of Reach of Children: Store lancets and lancing devices safely away from children.
- Sterility: Do not use if the protective cap or seal is damaged or missing.
Setup
Before performing a blood glucose test, ensure you have a ReliOn 30 Gauge Ultra-Thin Lancet, a compatible lancing device (sold separately), and a blood glucose meter with test strips.
- Wash Hands: Thoroughly wash your hands with soap and warm water. Dry them completely.
- Prepare Lancing Device: Remove the cap from your lancing device according to its specific instructions.
- Insert Lancet: Insert a new, sterile ReliOn 30 Gauge Ultra-Thin Lancet firmly into the lancing device.
- Remove Protective Disk: Twist off the protective disk from the lancet and save it for safe disposal after use. Do not discard the protective disk yet.
- Replace Lancing Device Cap: Carefully replace the cap on your lancing device.
- Adjust Depth Setting: Set the penetration depth on your lancing device to an appropriate level. Start with a shallower setting and adjust deeper if needed to obtain a sufficient blood sample.

Image: ReliOn 30 Gauge Ultra-Thin Lancets in their original packaging, showing the product name and gauge size.
Operating Instructions
Follow these steps to obtain a blood sample for glucose testing:
- Select Puncture Site: Choose a clean, dry area on your fingertip, preferably on the side, or an alternate site as recommended by your healthcare professional and lancing device instructions.
- Position Lancing Device: Place the lancing device firmly against the chosen puncture site.
- Activate Lancing Device: Press the release button on your lancing device to prick the skin.
- Obtain Blood Sample: Gently squeeze the area around the puncture site to form a small drop of blood. Avoid excessive squeezing, which can dilute the sample.
- Apply Blood to Test Strip: Touch the blood drop to the designated area on your blood glucose test strip, allowing it to draw in the sample. Follow your blood glucose meter's instructions for testing.
Maintenance
Proper maintenance primarily involves the safe disposal of used lancets.
- Recap Lancet: After obtaining your blood sample, carefully remove the lancing device cap. Place the protective disk (saved from step 4 of Setup) back onto the exposed lancet tip.
- Dispose Safely: Immediately dispose of the used, recapped lancet into an FDA-cleared sharps disposal container. If a sharps container is not available, use a heavy-duty plastic container (e.g., laundry detergent bottle) with a tight-fitting lid, clearly labeled "SHARPS – DO NOT RECYCLE."
- Do Not Reuse: Never attempt to clean or sterilize a used lancet for reuse.
Troubleshooting
If you encounter issues while using ReliOn 30 Gauge Ultra-Thin Lancets, consider the following:
- Difficulty Obtaining Blood Sample:
- Ensure your hands are warm before testing.
- Verify the lancing device depth setting is appropriate for your skin type. Adjust to a deeper setting if necessary.
- Try a different puncture site.
- Ensure you are adequately hydrated.
- Increased Pain During Puncture:
- Always use a new, sterile lancet for each test. Dull lancets cause more pain.
- Ensure the lancing device is held firmly against the skin to minimize movement during puncture.
- Consider using alternate sites if approved by your healthcare professional and lancing device.
Specifications
| Feature | Detail |
|---|---|
| Gauge | 30 Gauge (Ultra-Thin) |
| Quantity | 200 Lancets per pack (typically sold in multi-packs) |
| Compatibility | Compatible with most lancing devices (sold separately) |
| Sterility | Sterile, for single use only |
Warranty and Support
ReliOn 30 Gauge Ultra-Thin Lancets are consumable medical supplies. For specific product support, warranty information, or to report any issues, please refer to the contact details provided with your lancing device or contact ReliOn customer service directly. Always consult your healthcare professional for medical advice regarding your diabetes management.