Introduction
The B-Air VP-50 Air Mover is a powerful and energy-efficient unit designed for effective drying and air circulation in various environments. This manual provides essential information for the safe and optimal operation of your air mover. Please read all instructions carefully before use.
Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and personal injury.
- Ensure the unit is connected to a 110V/60Hz grounded outlet.
- Do not expose the unit to rain or use in damp locations.
- Keep children and pets away from the unit during operation.
- Do not operate the unit with a damaged cord or plug.
- Keep air inlets and outlets clear of obstructions.
- Always unplug the unit before performing any maintenance or cleaning.
Product Overview
The B-Air VP-50 Air Mover features a robust design and powerful performance for demanding tasks.
- Motor: Powerful and energy-efficient 1/4 HP sealed motor.
- Airflow: Maximum airflow capacity of 2950 CFM.
- Speed Control: Recessed and water-resistant 3-speed control switch.
- Positioning: Multiple drying positions (0°, 45°, and 90°).
- Stackability: Stacks firmly up to 5 units high for easy storage and transport.
- Housing: Extra tough, durable, and compact roto-molded housing design.
- Power Cord: 25 ft. commercial-grade power cord with wrap-around cord design.
- Stability: Non-marking and anti-skid rubber feet for secure placement.
- Filter: Optional filter kit available for added blower motor protection.

Figure 1: B-Air VP-50 1/4 HP Air Mover with handle and wheels.

Figure 2: Dimensions of the B-Air VP-50 Air Mover, showing its compact size.
Setup
- Unpacking: Carefully remove the air mover from its packaging. Inspect for any damage.
- Handle Assembly (if applicable): If your model includes a retractable handle, ensure it is securely attached and extends/retracts smoothly. Some models may require minor assembly for the handle and wheels.
- Placement: Position the air mover on a stable, level surface in the area requiring drying or air circulation. Ensure adequate clearance around the air inlets and outlets.
- Power Connection: Unwind the 25 ft. power cord completely. Plug the unit into a standard 110V/60Hz grounded electrical outlet.

Figure 3: The B-Air VP-50 Air Mover with its handle extended for easy transport.
Video 1: Demonstration of handle assembly and basic operation on a similar air mover model. Note: This video features a SUNMAX RT900a, which is a similar product, but not the exact B-Air VP-50.
Operating Instructions
- Power On: Locate the recessed control switch on the unit. Turn the dial from the 'OFF' position to select your desired speed setting (1, 2, or 3).
- Speed Selection: Choose from three available speeds to adjust the airflow intensity according to your needs. Speed 1 provides the lowest airflow, while Speed 3 provides the maximum airflow of 2950 CFM.
- Positioning: The B-Air VP-50 can be positioned in multiple angles to direct airflow precisely where needed. It supports 0° (flat on the ground), 45°, and 90° (vertical) drying positions. Adjust the unit to optimize drying for floors, walls, or ceilings.
- Daisy-Chaining (if applicable): The unit may feature auxiliary outlets. To connect multiple air movers, plug additional units into these outlets. Ensure the total amperage draw does not exceed the circuit breaker's limit (typically 12.0 Amps max with the unit off, 9.5 Amps max with the unit on).
- Power Off: To turn off the unit, rotate the control switch dial back to the 'OFF' position. Unplug the power cord from the outlet when not in use.

Figure 4: The B-Air VP-50 Air Mover positioned to direct airflow at an angle.

Figure 5: The air mover in use, drying a bathroom floor after a water incident.
Video 2: Overview and demonstration of a heavy-duty air mover, highlighting features like GFCI outlets, cord wrap, carpet clamp, multi-positioning, and ducting capabilities. Note: This video features an OdorStop OS2800, which is a similar product, but not the exact B-Air VP-50.
Maintenance
- Cleaning: Regularly wipe down the exterior of the unit with a damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Air Inlets/Outlets: Keep the air inlets and outlets free from dust, debris, and obstructions to ensure optimal airflow and prevent overheating.
- Power Cord: Inspect the power cord for any signs of damage (cuts, fraying) before each use. Do not use the unit if the cord is damaged. Utilize the wrap-around cord design for neat storage.
- Filter (Optional): If an optional filter kit is installed, follow the manufacturer's instructions for regular cleaning or replacement to maintain air quality and unit efficiency.
- Storage: Store the air mover in a cool, dry place when not in use. Its stackable design allows for efficient storage of multiple units.
Troubleshooting
- Unit Does Not Turn On:
- Check if the power cord is securely plugged into a grounded outlet.
- Verify that the outlet is functioning by plugging in another device.
- Ensure the control switch is set to one of the speed settings (1, 2, or 3) and not 'OFF'.
- If daisy-chaining, check the circuit breaker on the unit or the wall outlet.
- Reduced Airflow:
- Inspect air inlets and outlets for any blockages or debris.
- If an optional filter is installed, check if it is dirty and requires cleaning or replacement.
- Unusual Noise:
- Turn off and unplug the unit. Inspect the fan blades for any foreign objects.
- Ensure the unit is placed on a stable, level surface to prevent vibrations.
Specifications
| Feature | Specification |
|---|---|
| Brand | B-Air |
| Model Name | BA-VP-50H-GY |
| Output Power | 1/4 HP |
| Air Flow Capacity | 2950 CFM |
| Power Source | Corded Electric |
| Number of Power Levels | 3 |
| Item Weight | 25 Pounds |
| Product Dimensions | 20 x 26 x 24 inches |
| Cord Length | 25 ft. |
| Special Feature | Water Resistant |
| Housing | Roto-molded |
| Stackability | Up to 5 units |
Warranty and Support
For warranty information or technical support, please refer to the documentation included with your product or contact B-Air customer service directly. Keep your purchase receipt and serial number handy for any inquiries.