Bajaj DC 2050 DLX

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Bajaj DC 2050 DLX 70L Desert Air Cooler User Manual

Model: DC 2050 DLX

1. Introduction

Thank you for choosing the Bajaj DC 2050 DLX 70L Desert Air Cooler. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new appliance. Please read these instructions carefully before use and retain them for future reference.

Package Contents:

  • 1 x Bajaj DC 2050 DLX 70L Desert Air Cooler
  • User Manual
Bajaj DC 2050 DLX 70L Desert Air Cooler front view

Image 1.1: Front view of the Bajaj DC 2050 DLX 70L Desert Air Cooler.

2. Safety Instructions

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.

  • Ensure the power supply voltage matches the rating indicated on the appliance.
  • Do not operate the cooler with a damaged cord or plug.
  • Always unplug the cooler before filling water, cleaning, or performing any maintenance.
  • Do not immerse the cooler, cord, or plug in water or other liquids.
  • Keep the cooler away from children and pets.
  • Place the cooler on a stable, level surface.
  • Ensure adequate ventilation around the cooler.
  • Do not block air inlets or outlets.
  • Avoid using extension cords unless absolutely necessary and ensure they are rated for the appliance's power.

3. Setup

3.1 Unpacking

  1. Carefully remove the cooler from its packaging.
  2. Remove all packing materials, including any protective films or tapes.
  3. Inspect the cooler for any damage. If damaged, do not operate and contact customer support.

3.2 Placement

  • Place the air cooler on a firm, level surface.
  • For optimal cooling, position the cooler near an open window or door to draw in fresh air and allow humid air to escape.
  • Ensure there is at least 15-20 cm of space around the back and sides of the cooler for proper airflow.

3.3 Filling the Water Tank

  1. Ensure the cooler is unplugged from the power outlet.
  2. Locate the water inlet on the top of the cooler.
  3. Carefully pour clean water into the inlet until the water level indicator reaches the 'MAX' mark. Do not overfill. The tank capacity is 70 liters.
  4. Close the water inlet cover securely.
Top view of Bajaj DC 2050 DLX cooler with water inlet open

Image 3.1: Top view showing the water inlet for filling the tank.

Side view of Bajaj DC 2050 DLX cooler showing water level indicator

Image 3.2: Side view illustrating the water level indicator.

3.4 Power Connection

Plug the power cord into a suitable electrical outlet. Ensure the outlet is properly grounded.

4. Operating Instructions

The Bajaj DC 2050 DLX features simple knob controls for fan speed and cooling/swing functions.

Top panel of Bajaj DC 2050 DLX cooler with control knobs

Image 4.1: Control panel with fan and swing/pump knobs.

4.1 Power On/Off

  • To turn on the cooler, rotate the 'FAN' knob clockwise from the 'OFF' position.
  • To turn off the cooler, rotate the 'FAN' knob counter-clockwise to the 'OFF' position.

4.2 Adjusting Fan Speed

The cooler offers three fan speed settings: Low, Medium, and High.

  • Rotate the 'FAN' knob to select your desired speed: 1 (Low), 2 (Medium), or 3 (High).

4.3 Activating Cooling (Pump) and Swing Function

  • To activate the cooling function (water pump), rotate the 'SWING/PUMP' knob to the 'PUMP' position. Ensure the water tank is filled.
  • To activate the automatic swing function (louvers oscillate), rotate the 'SWING/PUMP' knob to the 'SWING' position.
  • To activate both cooling and swing, rotate the 'SWING/PUMP' knob to the 'SWING + PUMP' position.

    Video 4.1: Demonstration of the Bajaj DC 2050 DLX air cooler in operation, showing airflow and general function.

4.4 Using the Ice Chamber

For enhanced cooling, the cooler is equipped with an ice chamber.

  1. Open the ice chamber lid, usually located on the top of the cooler.
  2. Place ice cubes into the chamber.
  3. Close the lid securely. The melting ice will cool the water, providing colder air.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your air cooler.

5.1 Cleaning the Water Tank

  1. Unplug the cooler from the power supply.
  2. Drain any remaining water from the tank using the drain plug at the bottom/rear.
  3. Wipe the inside of the tank with a soft cloth and mild detergent. Rinse thoroughly with clean water.
  4. Ensure the tank is dry before refilling or storing.

5.2 Cleaning/Replacing Cooling Pads (Hexacool Technology)

The Hexacool pads are designed for efficient cooling and are anti-bacterial. Periodically inspect and clean them.

  1. Unplug the cooler.
  2. Carefully remove the back and side panels to access the cooling pads.
  3. Gently rinse the pads under running water to remove dust and mineral deposits. Do not scrub aggressively.
  4. Allow the pads to air dry completely before reinserting them.
  5. If pads are heavily soiled or damaged, replace them with genuine Bajaj Hexacool pads.
Rear view of Bajaj DC 2050 DLX cooler showing cooling pads

Image 5.1: Rear view displaying the cooling pads.

5.3 DuraMarine Pump

The DuraMarine Pump is designed with higher insulation for increased durability and protection against moisture. No specific user maintenance is required for the pump itself, but ensuring clean water and regular tank cleaning will prolong its life.

5.4 Exterior Cleaning

Wipe the exterior of the cooler with a soft, damp cloth. Do not use abrasive cleaners or solvents.

6. Troubleshooting

If you encounter issues with your air cooler, refer to the following table for common problems and solutions.

Problem Possible Cause Solution
Cooler does not turn on. No power supply.
Power cord not properly connected.
Check power outlet.
Ensure power cord is securely plugged in.
No cooling effect. Water tank empty.
Pump not activated.
Cooling pads are dry or clogged.
Fill water tank.
Turn 'SWING/PUMP' knob to 'PUMP' or 'SWING + PUMP'.
Clean or replace cooling pads.
Weak airflow. Fan speed set too low.
Air inlets/outlets blocked.
Increase fan speed.
Clear any obstructions around the cooler.
Unpleasant odor. Stagnant water or dirty cooling pads. Drain and clean the water tank.
Clean cooling pads.
Water leakage. Overfilling the water tank.
Drain plug not secured.
Do not overfill the tank.
Ensure drain plug is tightly closed.

If the problem persists after attempting these solutions, please contact Bajaj customer support.

7. Specifications

Feature Detail
Brand Bajaj
Model Name DC 2050 DLX
Water Tank Capacity 70 Litres
Air Flow Capacity 3400 Cubic Feet Per Minute (5600 CMH Peak)
Air Throw 80 Feet
Number of Speeds 3
Material Polypropylene (PP)
Mounting Type Freestanding
Controls Type Knob
Item Weight 19.5 kg (19500 Grams)
Dimensions (D x W x H) 50D x 64W x 108.5H Centimeters
Energy Consumption 200 Watts
Noise Level 70 Decibels
Special Features Adjustable Speed, DuraMarine Pump, Hexacool Technology Pads, Turbo Fan Technology, Ice Chamber
Bajaj DC 2050 DLX cooler with dimensions labeled

Image 7.1: Dimensions of the Bajaj DC 2050 DLX Air Cooler.

8. Warranty and Support

8.1 Product Warranty

  • The Bajaj DC 2050 DLX Air Cooler comes with a 1-year warranty on the product.
  • The DuraMarine Pump is covered by a separate 2-year warranty by Bajaj Electricals Ltd.
  • Please retain your purchase receipt for warranty claims.

8.2 Customer Support

For any warranty claims, installation services, or product-related inquiries, please reach out to Bajaj Consumer Care. Refer to the contact information provided in your warranty card or visit the official Bajaj website for details.

© 2023 Bajaj Electricals Ltd. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.