Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of the ABB ACS880-01-124A-5 Variable Frequency Drive (VFD). The ACS880 series is designed for a wide range of industrial applications, offering precise motor control and energy efficiency. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures.
Safety Information
Always observe the following safety precautions to prevent injury or damage to the equipment:
- Ensure all power is disconnected and locked out before performing any work on the drive or motor.
- Only qualified personnel should install, operate, and maintain this equipment.
- Verify proper grounding of the drive and motor.
- Do not touch electrical components when power is applied.
- Protect the drive from moisture, dust, and extreme temperatures.
- Use appropriate personal protective equipment (PPE).
Product Overview
The ABB ACS880-01-124A-5 is a high-performance variable frequency drive designed for demanding industrial applications. It features robust construction, advanced control algorithms, and a user-friendly interface.

Figure 1: Front view of the ABB ACS880-01-124A-5 Variable Frequency Drive. This image shows the compact design of the VFD, with its control panel visible on the front face, indicating its suitability for wall-mount installations.
Key Features:
- Model: ACS880-01-124A-5
- Power Rating: 75 Hp (Heavy Duty), 100 Hp (Normal Duty)
- Supply Voltage: 3-Phase, 380-500V AC
- Enclosure: NEMA 1 / IP21
- Mounting: Wall Mount
- Special Features: Coated Boards for enhanced durability.
Specifications
| Parameter | Value |
|---|---|
| Part Number | 6438177322191 |
| Supply Voltage | 3-Phase, 380-500V AC |
| Normal Duty Horsepower | 100 HP (124A) |
| Heavy Duty Horsepower | 75 HP (96A) |
| IP/NEMA Rating | NEMA 1 / IP21 |
| Frame Size | R6 |
| Dimensions (H x W x D) | 28.6" x 9.8" x 14.1" |
| Weight | 99.2 Lbs |
| Recommended Fuses | High Speed Fuses, Class T Size 200A |
| Cooling Method | Air |
| Coated Boards | Yes |
Setup and Installation
Proper installation is crucial for the safe and reliable operation of the VFD. Refer to the detailed wiring diagrams and mounting instructions provided with the product packaging for specific guidance.
General Steps:
- Mounting: Securely mount the drive vertically on a flat, stable surface, ensuring adequate clearance for ventilation.
- Power Wiring: Connect the 3-phase AC supply (380-500V) to the input terminals. Ensure correct phase sequence.
- Motor Wiring: Connect the motor to the output terminals of the VFD. Use shielded cables for motor connections to minimize electromagnetic interference.
- Grounding: Establish a proper earth ground connection for the drive and motor.
- Control Wiring: Connect control signals (e.g., start/stop, speed reference) to the appropriate control terminals.
- Fuses: Install recommended high-speed fuses (Class T Size 200A) on the input power lines.
Note: Always consult local electrical codes and regulations during installation.
Operating Instructions
Once installed and wired correctly, the VFD can be powered on and configured. The ACS880 features an intuitive control panel for parameter setting and monitoring.
Basic Operation:
- Power On: Apply main power to the VFD. The control panel will illuminate.
- Parameter Setup: Navigate through the control panel menu to set essential motor parameters (e.g., motor nominal voltage, current, frequency, speed) and application-specific parameters.
- Start/Stop: Use the designated start/stop inputs (digital inputs or control panel buttons) to control motor operation.
- Speed Control: Adjust the motor speed using the configured speed reference (e.g., analog input, keypad, fieldbus).
- Monitoring: The control panel displays real-time operational data such as motor speed, current, voltage, and fault status.
For advanced programming and specific application modes, refer to the comprehensive ABB ACS880 programming manual.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your VFD. Always disconnect power before performing any maintenance.
- Cleaning: Periodically clean the exterior of the drive and ensure ventilation openings are free from dust and debris. Use a soft, dry cloth.
- Fan Check: Inspect cooling fans for proper operation and cleanliness. Replace if noisy or not functioning correctly.
- Terminal Connections: Annually check all electrical connections for tightness. Loose connections can cause overheating and damage.
- Capacitor Life: Power capacitors have a finite lifespan. Consult the drive's technical documentation for expected life and replacement intervals.
Troubleshooting
This section provides guidance for common issues. For detailed fault codes and advanced troubleshooting, refer to the drive's fault tracing manual.
| Problem | Possible Cause | Solution |
|---|---|---|
| Drive does not power on | No input power; Blown fuses | Check main power supply; Inspect and replace fuses. |
| Motor does not start | Incorrect control wiring; Parameter error; Fault active | Verify control connections; Check motor and application parameters; Clear active faults. |
| Overcurrent fault | Motor overload; Short circuit in motor wiring; Incorrect motor parameters | Reduce load; Check motor wiring for shorts; Verify motor parameters. |
| Overvoltage fault | High input voltage; Regenerative braking without braking resistor | Check input voltage; Install or check braking resistor. |