Lindby 9613070

Lindby Tommi Modern Plaster Wall Lamp User Manual

Model: 9613070

Brand: Lindby

Introduction

Thank you for choosing the Lindby Tommi Modern Plaster Wall Lamp. This manual provides essential information for the safe installation, operation, and maintenance of your new lighting fixture. Please read these instructions carefully before installation and retain them for future reference.

Important Safety Instructions

Package Contents

Verify that all components are present before beginning installation:

Specifications

Diagram showing the dimensions of the Lindby Tommi wall lamp: 100 cm length, 10.5 cm height, and 15 cm depth.

Image: Product dimensions diagram.

FeatureDetail
BrandLindby
Model NameTommi
Model Number9613070
Product Dimensions (L x W x H)15L x 100W x 10.5H centimeters
Weight3.1 Kilograms
MaterialPlaster
ColorWhite
StyleModern
Room TypeLiving Room
Indoor/Outdoor UseIndoor
Power SourceCorded Electric
Special FeaturesDimmable
Control MethodTouch (referring to switch type, likely external)
Light SourceLED (recommended, bulbs not included)
Number of Light Sources4
Voltage230 Volts
Light ColorWarm White (with appropriate bulbs)
Wattage25 watts (max per bulb)
Lamp FittingE14
Switch TypeRotary Switch (external, not integrated)
Water Resistance LevelNot Water Resistant
Brightness1000 lumens (with appropriate bulbs)
Mounting TypeWall Mount
Installation TypeRecessed Mount
Assembly RequiredNo (referring to the fixture itself, but installation is required)

Setup and Installation

Before you begin: Ensure the power supply to the installation area is turned off at the circuit breaker. It is recommended to have a qualified electrician perform the installation.

  1. Prepare the Mounting Location: Choose a suitable wall location for the lamp. Ensure there is adequate space and access to electrical wiring.
  2. Mark Drilling Points: Hold the mounting bracket (or the lamp itself if the bracket is integrated) against the wall at the desired installation height. Use a pencil to mark the drilling points for the screws.
  3. Drill Holes: Drill holes at the marked points. Insert appropriate wall anchors if necessary, depending on your wall material.
  4. Attach Mounting Bracket: Secure the mounting bracket to the wall using the provided screws. Ensure it is firmly attached.
    Close-up of the Lindby Tommi wall lamp's internal wiring and mounting bracket.

    Image: Internal view of the lamp showing the mounting bracket and wiring terminals.

  5. Electrical Connection: Connect the electrical wires from the wall to the lamp's terminal block.
    • Connect the live wire (usually brown or black) to the 'L' terminal.
    • Connect the neutral wire (usually blue) to the 'N' terminal.
    • Connect the earth wire (usually green/yellow) to the earth terminal (marked with ⚡).
    Ensure all connections are secure.
    Detailed view of the electrical wiring connections inside the Lindby Tommi wall lamp.

    Image: Close-up of the electrical terminal block for wiring connections.

  6. Install Light Bulbs: Insert four E14 base light bulbs (not included) into the lamp holders. Do not exceed 25 watts per bulb.
    Interior view of the Lindby Tommi wall lamp showing the E14 bulb sockets.

    Image: Interior of the lamp with bulb sockets visible.

  7. Mount the Lamp Fixture: Carefully align the lamp fixture with the mounting bracket and secure it in place. Ensure it is stable and flush against the wall.
  8. Restore Power: Once the installation is complete and all connections are secure, restore power at the main circuit breaker.
  9. Test the Lamp: Turn on the light switch to ensure the lamp is functioning correctly.
Installation Video Guide

Video: Product demonstration and installation guide for a similar wall lamp. This video illustrates the general installation process.

Video: Short demonstration of an LED wall light, showing its warm light output and elegant profile.

Operating Instructions

The Lindby Tommi wall lamp is designed for simple operation via a standard wall switch. If connected to a compatible dimmer switch, the light output can be adjusted.

Maintenance

Troubleshooting

ProblemPossible Cause / Solution
Lamp does not light up.
  • Check if the power supply is on at the circuit breaker.
  • Ensure the wall switch is in the 'ON' position.
  • Verify that the bulbs are correctly installed and not faulty. Replace if necessary.
  • Check electrical connections for looseness or incorrect wiring (consult a qualified electrician).
Light flickers.
  • Ensure bulbs are fully screwed in.
  • If using a dimmer, ensure both the bulbs and the dimmer switch are compatible with each other.
  • Loose wiring connection (consult a qualified electrician).
Lamp is physically damaged.
  • Due to the plaster material, the lamp can be fragile. Handle with care. Minor imperfections are normal for plaster products. For significant damage, contact customer support.

Warranty and Support

For warranty information, please refer to the terms and conditions provided at the point of purchase or contact your retailer. Lindby products are designed for quality and durability.

If you encounter any issues or require assistance, please contact Lindby customer support or your authorized dealer. Please have your model number (9613070) and purchase details ready.

For more information about Lindby products, visit the official Lindby brand store: Lindby Brand Store.