1. Introduction
Thank you for choosing the VEVOR High Pressure Hand Pump. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your 3-stage airgun PCP filling stirrup pump. Please read this manual thoroughly before use and retain it for future reference.
2. Safety Information
WARNING: This device operates under high pressure. Failure to follow safety instructions can result in serious injury or property damage.
- Always wear appropriate eye protection when operating the pump.
- Ensure all connections are secure before pressurizing.
- Do not exceed the maximum pressure rating of the pump (4500 PSI / 30 MPa) or the device being inflated.
- Keep hands and fingers clear of moving parts during operation.
- Do not modify the pump or its components. Use only original replacement parts.
- Keep out of reach of children.
- Avoid prolonged pumping without breaks to prevent overheating.
3. Package Contents
- 1 x Stirrup Pump 4500 psi (0-30 MPa)
- 1 x Set of O-rings, Complete Accessories and Tools
- 1 x Operation Instruction


4. Setup and Assembly
Follow these steps to assemble your VEVOR High Pressure Hand Pump:
- Attach the handle to the top of the pump shaft.
- Secure the base to the bottom of the pump cylinder using the provided tools.
- Connect the high-pressure hose to the pump's outlet. Ensure a tight seal.
- If necessary, install the appropriate adapter or nozzle for your specific inflation task.
Video: How to Install an Airgun Pump - Early Part
This video demonstrates the initial steps for installing and assembling the airgun pump, including attaching the handle and base components.
Video: How to Install an Airgun Pump - Later Part
This video continues the installation process, showing how to connect the high-pressure hose and other final assembly steps.
5. Operating Instructions
The VEVOR High Pressure Hand Pump is designed for efficient and labor-saving inflation of various high-pressure items.
- Place the pump on a stable, flat surface and firmly step on the base.
- Connect the pump hose securely to the item you wish to inflate.
- Begin pumping with smooth, consistent strokes. The 3-stage design reduces effort compared to traditional pumps.
- Monitor the pressure gauge (Figure 4) to ensure you do not exceed the recommended pressure for your item. The gauge provides accurate readings up to 4500 PSI (30 MPa).
- Once the desired pressure is reached, stop pumping and disconnect the hose.





6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your pump.
- Lubrication: Periodically apply the provided lubricant to the pump shaft and internal components as instructed.
- O-Ring Replacement: The pump comes with a set of spare O-rings. Replace worn or damaged O-rings promptly to maintain a proper seal and prevent air leaks.
- Moisture Filter: The built-in oil-water separator helps remove moisture. Regularly check and replace the desiccant filter material to ensure effective moisture removal.
- Cleaning: Keep the exterior of the pump clean and free from dirt and debris.
Video: How to Disassemble
This video provides a step-by-step guide on how to safely disassemble the pump for cleaning, lubrication, and replacement of internal components like O-rings.
7. Troubleshooting
If you encounter issues with your pump, refer to the following common problems and solutions:
- Pressure Loss: If the pressure gauge drops slowly after pumping, check all connections for tightness. Inspect O-rings for wear or damage and replace if necessary. Ensure the pressure relief screw is fully closed.
- Difficulty Pumping: Ensure the pump is adequately lubricated. Check for any obstructions in the air path.
- No Pressure Build-up: Verify that all internal seals and O-rings are correctly installed and not damaged. Refer to the disassembly video for inspection.
Video: How to Do Fault Detection
This video guides you through the process of identifying common faults and issues with the pump, helping you diagnose and resolve problems effectively.
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | DQT-3JH |
| Brand | VEVOR |
| Material | Stainless Steel |
| Item Weight | 6 Pounds (2.7 kg) |
| Product Dimensions (L x W x H) | 10"L x 5.2"W x 24.7"H (25.4 cm x 13.2 cm x 62.7 cm) |
| Power Source | Hand Pump |
| Air Flow Capacity | 5 Liters Per Minute |
| Maximum Pressure | 4500 Pound per Square Inch (30 MPa) |
| Operation Mode | Manual |
| Hose Length | 50 Centimeters (19.7 inches) |
| UPC | 719034896960 |

9. Warranty and Support
This VEVOR product is covered by a warranty as per the manufacturer's terms. For specific warranty details, please refer to the documentation included with your purchase or contact VEVOR customer support.
Return Policy: This product is eligible for a 30-day refund/replacement policy through Amazon.