DuraWater Fleck 5600

DuraWater Fleck 5600 Water Softener 12-Day Timer Valve Instruction Manual

Model: Fleck 5600 | Brand: DuraWater

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your DuraWater Fleck 5600 Water Softener 12-Day Timer Control Valve (110V). The Fleck 5600 is designed for whole-house water softening, featuring a simple mechanical design that is easy to understand and program. It is built with heavy-duty 3/8" wide plastic gears for durability and includes a non-corrosive, UV-resistant fiber-reinforced polymer valve body. The system is economical, with small annual power consumption, and is designed with double backwash for efficient operation.

2. Product Overview

The Fleck 5600 12-Day Timer Valve is a robust control unit for water softener systems. Its user-friendly controls allow for straightforward programming of regeneration cycles. Key features include:

  • Simple mechanical design for ease of use.
  • Ruggedly built timer with heavy-duty 3/8" wide plastic gears.
  • User-friendly and easy-to-program controls.
  • Non-corrosive, UV-resistant fiber-reinforced polymer valve body.
  • Economical operation with low annual power consumption.
  • Keeps time and activates piston/valve mechanics with a single motor.
  • Designed with double backwash for enhanced regeneration.

3. Components

The primary component included is the Fleck 5600 Timer Water Softener Control Valve. Additional parts for installation may vary based on your specific system configuration.

DuraWater Fleck 5600 Water Softener 12-Day Timer Valve

Figure 1: DuraWater Fleck 5600 Water Softener 12-Day Timer Valve.

DuraWater Fleck 5600 Water Softener 12-Day Timer Valve with accessories

Figure 2: DuraWater Fleck 5600 Water Softener 12-Day Timer Valve shown with various installation accessories.

4. Setup

4.1 Pre-Installation Checklist

  • Ensure all components are present and undamaged.
  • Verify the power supply is 110V as required by the valve.
  • Confirm water supply can be shut off and drained.
  • Have necessary plumbing tools and materials available.

4.2 Installation Guidelines

Installation of a water softener control valve typically involves plumbing connections to the main water line, a drain line, and a brine tank. Due to the complexity and potential for water damage, it is highly recommended that installation be performed by a qualified plumber or water treatment professional. Refer to the detailed plumbing diagrams provided with your complete water softener system for specific connection points.

4.3 Power Connection

Once the valve is physically installed and plumbed, connect the 110V power cord to a grounded electrical outlet. The timer will begin to operate.

5. Operating Instructions

The Fleck 5600 12-Day Timer Valve uses mechanical dials for setting. Follow these steps to configure your valve:

5.1 Setting Water Capacity

  1. Locate the 'CAPACITY' dial on the control head.
  2. Align the desired capacity setting (e.g., 30 for 3000 liters, assuming a 100x multiplier) with the white dot indicator.
  3. Ensure the arrow on the transparent dial is also aligned with the white dot.

Video 1: Instructions on setting the water capacity and time of day on the Fleck 5600 mechanical timer valve.

5.2 Setting Current Time

  1. After setting the flow rate scale, locate the 'TIME OF DAY' dial.
  2. Press the red button on the control head.
  3. Rotate the large gear until the current time (e.g., 9 AM) aligns with the 'TIME OF DAY' arrow.

5.3 Regeneration Process

The regeneration time is fixed. When the set flow value (capacity) is reached, the valve will initiate a regeneration cycle at the programmed regeneration time. This ensures your water softener is always ready to provide soft water.

6. Maintenance

Regular maintenance ensures the longevity and efficiency of your water softener system. Key maintenance tasks include:

  • Salt Level Monitoring: Periodically check the salt level in your brine tank. Ensure it remains above the water level to allow for proper brine solution formation.
  • Cleaning: Keep the exterior of the control valve clean and free from dust or debris.
  • System Checks: Occasionally observe the regeneration cycle to ensure it progresses through all stages correctly.
  • Professional Servicing: Consider annual professional servicing to inspect internal components and ensure optimal performance.

7. Troubleshooting

If you encounter issues with your Fleck 5600 valve, consider the following general troubleshooting steps:

  • No Soft Water: Check salt levels in the brine tank. Ensure the time of day and regeneration settings are correct. Verify the bypass valve is in the 'service' position.
  • Continuous Regeneration: Inspect the timer mechanism for any obstructions or damage. Ensure the red button is not stuck.
  • Water Leaks: Check all plumbing connections for tightness. Inspect the valve body for cracks or damage.
  • Timer Not Advancing: Ensure the unit is receiving power. Check for any mechanical obstructions preventing the gears from turning.

For persistent issues, consult a qualified water treatment professional.

8. Specifications

Attribute Value
Brand DuraWater
Model Fleck 5600 12-Day Timer Valve
Voltage 110V
Color Black
Material Plastic
Number of Settings 12 (Day Timer)
Product Dimensions 10 x 10 x 10 inches
Item Weight 10 pounds