1. Product Overview
The KNACRO 2-Channel Relay Module is a versatile control unit designed for various automation and control applications. It features two independent high-power relays, each capable of switching loads up to DC 30V 30A or AC 250V 30A. The module incorporates optocoupler isolation for enhanced anti-interference capabilities, ensuring reliable operation by separating the control circuit from the load circuit. Each channel includes an LED indicator to show the relay's status.
This module is suitable for PLC automation equipment control, industrial system control, logistics network control, smart home product integration, and experimental development for electronic enthusiasts.
2. Key Features
- High-Power Relays: Equipped with two high-power relays, each supporting a maximum control load of DC 30V 30A or AC 250V 30A.
- Optocoupler Isolation: Each channel features optocoupler isolation, providing strong anti-interference ability and ensuring safety by separating control and load circuits.
- Safety Standards: Designed with an isolation slot between the control area and the load area, adhering to international safety standards.
- LED Indicators: Each relay channel includes an LED indicator to visually confirm its operational status.
- Wide Application: Ideal for PLC automation, industrial control systems, logistics networks, smart home devices, and various electronic development projects.
- Flexible Triggering: Supports both high-level and low-level trigger modes, adaptable to different control signals.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Supply Voltage | DC 24V |
| Quiescent Current | 5mA |
| Maximum Operating Current | 190mA |
| Trigger Mode | High and Low Level Trigger |
| Load Voltage (Max) | DC 30V / AC 250V |
| Load Current (Max) | 30A |
| Relay Life | > 100,000 times |
| Dimensions (L*W*H) | 70 * 72 * 22mm |
| Weight | 93g |
| Coil Voltage | 24 volts |
Trigger Voltage Ranges (for 24V module):
- Low-level trigger: 0-12V relay ON; 12-24V relay OFF.
- High-level trigger: 12-24V relay ON; 0-8.5V relay OFF.
4. Setup and Wiring
Proper wiring is crucial for the safe and correct operation of the relay module. Refer to the diagrams and instructions below for connecting the power supply, control signals, and load.
4.1 Module Layout

Figure 4.1: Top view of the KNACRO 2-Channel Relay Module. This image displays the two blue Songle relays, the input terminal block (DC+, GND, VCC, IN1, IN2, COM), and the output terminal blocks for the load connections (NO, NC, COM for each relay).

Figure 4.2: Angled view of the relay module, highlighting the input and output terminal blocks. The input block includes connections for power (DC+, GND, VCC) and control signals (IN1, IN2, COM), while the output blocks provide Normally Open (NO), Normally Closed (NC), and Common (COM) terminals for each relay.
4.2 Power Supply Connection
- Connect the positive terminal of your DC 24V power supply to the DC+ terminal on the module.
- Connect the negative terminal (ground) of your DC 24V power supply to the GND terminal on the module.
- The VCC terminal is typically connected to DC+ for the module's internal power, but can be isolated for specific applications. For standard use, connect VCC to DC+.
- Ensure the power supply voltage matches the module's rated voltage (DC 24V for this model).
4.3 Control Signal Connection
The module supports both high-level and low-level triggering. The trigger mode is selected via a jumper on the module (labeled "Low" and "High").

Figure 4.3: Close-up view of the jumper settings for selecting high or low-level trigger mode. The jumper connects the signal input (IN1, IN2) to either the "Low" or "High" pin, determining the active state of the control signal.
- Connect your control signal source (e.g., Arduino, PLC output) to the IN1 and IN2 terminals for Relay 1 and Relay 2, respectively.
- Connect the ground of your control signal source to the COM terminal on the module's input side.
- Jumper Setting:
- Low-Level Trigger: Position the jumper to connect the signal pin to the "Low" pin. The relay will activate when the input signal (IN1/IN2) is between 0-12V.
- High-Level Trigger: Position the jumper to connect the signal pin to the "High" pin. The relay will activate when the input signal (IN1/IN2) is between 12-24V.
4.4 Load Connection
Each relay provides three terminals for load connection: Normally Open (NO), Normally Closed (NC), and Common (COM).

Figure 4.4: Angled view of the relay module, focusing on the output terminal blocks. Each relay has three terminals: Normally Open (NO), Normally Closed (NC), and Common (COM), allowing for flexible load control configurations.
- Common (COM): This is the central terminal for the load circuit. Connect one side of your load's power source (or the load itself) to this terminal.
- Normally Open (NO): When the relay is OFF (not activated), there is no connection between COM and NO. When the relay is ON (activated), COM and NO are connected, completing the circuit.
- Normally Closed (NC): When the relay is OFF (not activated), COM and NC are connected. When the relay is ON (activated), the connection between COM and NC is broken.
- Connect your load according to your desired operation (e.g., for a load to turn ON when the relay activates, connect it between COM and NO).
- Ensure the load's voltage and current do not exceed the relay's maximum ratings (DC 30V 30A / AC 250V 30A).
5. Operation
Once the module is correctly wired and powered, its operation is determined by the control signals applied to the IN1 and IN2 terminals, in conjunction with the selected trigger mode.
5.1 Relay Activation
- When a control signal matching the selected trigger mode (high or low level) is applied to IN1 or IN2, the corresponding relay will activate.
- Upon activation, the LED indicator for that channel will illuminate.
- The internal contacts of the relay will switch: the connection between COM and NC will open, and the connection between COM and NO will close.
5.2 Relay Deactivation
- When the control signal is removed or changes to the inactive state (opposite of the trigger mode), the relay will deactivate.
- The LED indicator for that channel will turn off.
- The internal contacts will return to their default state: COM and NC will reconnect, and COM and NO will open.
Each relay operates independently, allowing for separate control of two distinct loads.
6. Maintenance
The KNACRO 2-Channel Relay Module is designed for reliable operation with minimal maintenance. Adhering to the following guidelines will help ensure its longevity:
- Cleanliness: Keep the module free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners.
- Environmental Conditions: Operate the module within its specified temperature and humidity ranges. Avoid extreme temperatures or high humidity environments.
- Connection Integrity: Periodically check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or damage.
- Load Management: Do not exceed the maximum specified load voltage and current for the relays. Overloading can significantly reduce relay life and cause damage.
- Physical Handling: Handle the module with care to avoid physical damage to components or solder joints.
7. Troubleshooting
If you encounter issues with your KNACRO 2-Channel Relay Module, refer to the following common problems and solutions:
| Problem | Possible Cause & Solution |
|---|---|
| Relay does not activate (LED off) |
|
| Relay activates but load does not turn ON/OFF |
|
| Module powers ON but relays chatter or behave erratically |
|
8. Warranty and Support
KNACRO products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided with your purchase or contact your retailer. If you encounter any issues or require technical assistance, please reach out to KNACRO customer support through the platform where the product was purchased.