1. Introduction

The Amplim AMP1701 is a medical-grade non-contact infrared thermometer designed for fast and accurate temperature measurement. It is suitable for use on adults, children, and infants, providing a hygienic and convenient method for fever detection in various settings including home, clinics, and offices.

Amplim AMP1701 Non-Contact Infrared Forehead Thermometer

Image: The Amplim AMP1701 Non-Contact Infrared Forehead Thermometer, a white and gray device with a digital display.

2. Product Features

The Amplim AMP1701 thermometer offers several key features for reliable temperature measurement:

  • Non-Contact Measurement: Allows for hygienic temperature taking without physical contact.
  • Fast and Accurate Readings: Provides instant results for quick assessment.
  • Multi-Mode Functionality: Includes Forehead Mode for body temperature and Surface Mode for object temperature.
  • Color-Coded LCD Display: Screen changes color (Green, Orange, Red) to indicate temperature status (Normal, Elevated, High Fever).
  • Memory Storage: Stores up to 32 previous readings for tracking temperature trends.
  • Switchable Units: Easily toggle between Fahrenheit (°F) and Celsius (°C).
  • Fever Alarm: Audible and visual alarm for high fever detection.
  • Buzzer ON/OFF: Option to mute the device for quiet operation, especially at night.
  • Automatic Power-Off: Conserves battery life by shutting down after 30 seconds of inactivity.
  • Low Battery Indicator: Alerts when batteries need replacement.
  • FDA Cleared: Meets regulatory standards for medical devices.
Diagram illustrating Amplim AMP1701 thermometer features like forehead mode, surface mode, fever alarm, LCD display, accuracy, memory, fast readings, buzzer, Fahrenheit/Celsius, FDA cleared, and auto power off.

Image: Visual representation of the thermometer's key features, including icons for forehead mode, surface mode, fever alarm, and memory.

3. What's in the Box

Upon opening the package, you should find the following items:

  • 1 x Amplim AMP1701 Non-Contact Infrared Forehead Thermometer
  • 2 x AAA Batteries (included)
  • 1 x User Manual (this document)
  • 1 x One Year Warranty Card
  • 1 x Certificate
Amplim AMP1701 thermometer packaging showing contents and features.

Image: The product box displaying the thermometer and listing its contents and features.

4. Setup: Battery Installation

The thermometer requires two AAA batteries for operation. These are included in the package.

  1. Locate the battery compartment cover on the back of the thermometer.
  2. Slide the cover downwards to open the compartment.
  3. Insert the two AAA batteries, ensuring the positive (+) and negative (-) terminals are aligned correctly according to the markings inside the compartment.
  4. Slide the battery compartment cover back into place until it clicks securely.

Note: Always use new batteries and dispose of old batteries responsibly.

5. Operating Instructions

5.1. Power On/Off

  • To turn on: Press the PWR/SET button once. The display will show 'Body', '°F' or '°C', and a sound icon.
  • To turn off: The device will automatically power off after 30 seconds of inactivity to conserve battery.

5.2. Taking a Temperature Reading (Forehead Mode)

This mode is used for measuring human body temperature.

  1. Ensure the thermometer is in Body mode (indicated on the display). If not, refer to Section 5.3 to switch modes.
  2. Aim the thermometer at the center of the forehead, maintaining a distance of approximately 1.2 to 2 inches (3-5 cm) from the skin.
  3. Press the SCAN/OPT button once. The temperature reading will appear on the display almost instantly.
  4. The display backlight color indicates the temperature status:
    • Green: Normal temperature (e.g., below 99.1°F).
    • Orange: Elevated temperature (e.g., 99.3-100.2°F).
    • Red: High temperature / Fever (e.g., above 100.4°F).
Amplim AMP1701 thermometer showing color-coded display for normal, elevated, and high temperatures.

Image: Examples of the color-coded display indicating normal (green), elevated (orange), and high (red) temperatures.

5.3. Switching Between Forehead Mode and Surface Mode

The thermometer can measure both body temperature and surface temperature of objects.

  1. With the thermometer powered on, press and hold the PWR/SET button for 3 seconds to enter Setup Mode.
  2. Press the SCAN/OPT button to toggle between 'Body' (forehead mode) and 'Surface Temp' (surface mode).
  3. Press the PWR/SET button again to confirm your selection and exit Setup Mode.
Amplim AMP1701 thermometer demonstrating tri-mode functionality for body, liquid, and room temperature measurement.

Image: The thermometer being used to measure body temperature, liquid temperature, and room temperature, illustrating its tri-mode capability.

5.4. Switching Between Fahrenheit (°F) and Celsius (°C)

  1. With the thermometer powered on, press and hold the PWR/SET button for 3 seconds to enter Setup Mode.
  2. Press the MEM/ENTR button to toggle between °F and °C.
  3. Press the PWR/SET button again to confirm your selection and exit Setup Mode.

5.5. Memory Function

The thermometer automatically stores the last 32 temperature readings.

  • To view previous readings: With the thermometer powered on, press the MEM/ENTR button. Each press will cycle through the stored readings.
  • To clear memory: This function is typically performed through a specific setup menu option. Refer to the detailed manual for advanced memory management.

5.6. Buzzer ON/OFF

You can enable or disable the audible buzzer for temperature readings.

  1. With the thermometer powered on, press and hold the PWR/SET button for 3 seconds to enter Setup Mode.
  2. Press the SCAN/OPT button repeatedly until the buzzer icon appears/disappears or 'ON'/'OFF' is displayed.
  3. Press the PWR/SET button again to confirm your selection and exit Setup Mode.
Amplim AMP1701 thermometer showing night light mode with buzzer on/off option.

Image: The thermometer display in night light mode, highlighting the buzzer on/off feature for quiet operation.

6. Important Notes and Safety Information

  • This thermometer is not intended as a substitute for consultation with a physician. Always seek professional medical advice for health concerns.
  • Forehead temperature is typically 0.5-1.0°F (0.3-0.6°C) lower than oral temperature. Average normal forehead temperature ranges from 97.0-98.9°F (36.1-37.2°C).
  • If the temperature displayed is lower than 89.6°F (32°C) or if the thermometer is aimed at the air instead of the forehead, the display may show 'Lo'. Retake the temperature by aiming the thermometer at the center of the forehead, between 1.2"-2" from the skin.
  • An impact or drop may damage the product accuracy. Handle with care.
  • Allow the thermometer to acclimate to ambient temperature for at least 30 minutes if there is a significant change in the environment (e.g., moving from outdoors to indoors).
  • Allow 3-5 seconds between consecutive measurements for optimal accuracy.
Important notes regarding thermometer usage and temperature interpretation.

Image: A close-up of the thermometer with important usage notes and disclaimers.

7. Normal Body Temperature Range

Normal body temperature can vary by age. The following table provides general reference ranges for forehead temperature:

Years0 - 23 - 1011 - 65> 65
°F97.5 - 100.497.0 - 100.096.6 - 99.796.4 - 99.5

Note: Temperature is higher than 109.4°F (43°C) is considered a critical fever.

8. Maintenance and Care

  • Cleaning: Wipe the thermometer with a soft cloth. For disinfection, use an alcohol wipe or a cloth dampened with isopropyl alcohol (70%). Do not immerse the thermometer in water or any cleaning solution.
  • Storage: Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it out of reach of children.
  • Battery Replacement: Replace batteries when the low battery indicator appears on the display. Ensure correct polarity when inserting new batteries.

9. Troubleshooting

  • 'Lo' Message: If the display shows 'Lo', it indicates the measured temperature is below 89.6°F (32°C) or the thermometer was not aimed correctly. Ensure the thermometer is aimed at the center of the forehead, 1.2"-2" from the skin, and retake the measurement.
  • Inaccurate Readings: Ensure the thermometer has acclimated to the ambient room temperature for at least 30 minutes. Avoid taking measurements immediately after strenuous activity, bathing, or eating. Ensure there is no hair or perspiration on the forehead.
  • No Display: Check if the batteries are inserted correctly and are not depleted. Replace batteries if necessary.

10. Specifications

  • Product Dimensions: 2.72 x 1.65 x 7.99 inches
  • Weight: 4.97 ounces
  • Power Source: 2 AAA batteries (included)
  • Measurement Range: Body Mode: 89.6°F - 109.4°F (32°C - 43°C)
  • Measurement Distance: 1.2" - 2" (3-5 cm)
  • Memory: 32 readings
  • Auto Power Off: 30 seconds
  • Display Type: Digital LCD with color-coded backlight
  • Material: Plastic
  • Special Features: °F/°C Switchable, No Mercury, Battery Operated, Low Battery Indicator, FDA Cleared, Fast Reading System, 3 Colors Fever Alarm, Buzzer ON/OFF, Ultra Fast, 32X Memory, Forehead/Surface Mode, High Accuracy, Large Display, Non-Contact, Ultra Clear Screen.

11. Warranty and Support

The Amplim AMP1701 Non-Contact Infrared Forehead Thermometer comes with a One Year Warranty. For any product issues, technical support, or warranty claims, please contact Amplim customer support.

Customer Support: customersupport@amplim.com

Related Documents - 1701

PreviewLEGO Star Trek USS Enterprise NCC-1701-D (10356) Building Instructions
Detailed step-by-step instructions for building the LEGO Star Trek USS Enterprise NCC-1701-D model (set 10356). A guide for adult fans and collectors.
PreviewLEGO Star Trek U.S.S. Enterprise NCC-1701-D (10356) Building Instructions
Detailed step-by-step building instructions for the LEGO Star Trek U.S.S. Enterprise NCC-1701-D model set 10356. Perfect for adult fans and LEGO collectors.
PreviewOlympus Lock Price List - Commercial Cabinet Locks and Accessories
Comprehensive price list for Olympus Lock's commercial grade cabinet locks, padlocks, and accessories, featuring detailed specifications, keying information, and ordering guides for institutional applications.
PreviewSonoStar CProbe Wireless Ultrasound Scanner User's Guide
Official user's guide for the SonoStar CProbe wireless probe type ultrasound scanner, detailing features, technical specifications, indications for use, safety precautions, and operating instructions for medical professionals.
PreviewAxonics Sacral Neuromodulation System PNE Lead Implant Manual
Guide detailing the implantation procedure for the Axonics Sacral Neuromodulation System PNE Lead (Model 1901) and Kit (Model 1701). Covers system components, safety warnings (Diathermy, MRI, EMI), patient activities, and handling instructions for this medical device.
PreviewManuel de l'électrode implantable PNE Axonics
Manuel d'implantation et d'utilisation pour l'électrode PNE (modèle 1901) et la trousse d'implantation (modèle 1701) du système Axonics Sacral Neuromodulation (SNM). Ce document détaille les spécifications, le contenu de l'emballage, les procédures de préparation, d'implantation, de test de stimulation et de retrait de l'électrode.