Introduction
Thank you for choosing the Philips Viva Collection Masticating Juicer HR1887/81. This appliance is designed to extract juice from various fruits and vegetables efficiently, preserving nutrients through its slow juicing technology. Please read this instruction manual carefully before using the appliance and save it for future reference.

Image: Philips Viva Collection Masticating Juicer HR1887/81, showing the assembled unit with juice and pulp containers.
Important Safety Information
Read all instructions before use. Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and personal injury.
- Do not immerse the motor unit in water or any other liquid.
- Ensure the appliance is correctly assembled before operation.
- Keep hands and utensils out of the feeding tube during operation to prevent injury.
- Always unplug the appliance before cleaning or disassembling.
- Do not use the appliance if the cord, plug, or other parts are damaged.
- This appliance is for household use only.
Product Overview
Familiarize yourself with the components of your Philips Masticating Juicer HR1887/81.
- Pusher
- Feeding tube (XL 70mm)
- Auger (masticating screw)
- Filter
- Juice outlet with drip stop
- Pulp outlet
- Motor unit
- Juice container
- Pulp container

Image: Overview of the Philips Masticating Juicer, highlighting its slow juicing technology and XL feeding tube.
Setup and Assembly
Before first use, wash all detachable parts thoroughly.
- Place the motor unit on a stable, flat surface.
- Insert the filter into the juicing bowl, ensuring it clicks into place.
- Place the auger inside the filter.
- Attach the feeding tube assembly to the motor unit, aligning the arrows and twisting until it locks.
- Position the juice container under the juice outlet and the pulp container under the pulp outlet.
- Ensure the drip stop is closed before starting.
Video: A demonstration of assembling the Philips Viva Collection Masticating Juicer, showing how to attach the juicing components and containers.
Operating Instructions
Preparing Ingredients
- Wash fruits and vegetables thoroughly.
- For fruits with hard pits (e.g., peaches, plums), remove the pits.
- Peel fruits with thick skins (e.g., oranges, pineapples).
- The XL 70mm feeding tube can accommodate larger pieces, reducing pre-cutting. However, for very fibrous vegetables like celery, it is recommended to cut them into smaller pieces to prevent clogging.
Juicing Process
- Plug in the appliance.
- Switch on the juicer.
- Slowly feed the prepared ingredients into the feeding tube. Use the pusher only if necessary to guide ingredients.
- The juicer will extract juice into the juice container and separate pulp into the pulp container.
- Once juicing is complete, switch off the appliance and unplug it.
- Open the drip stop to release any remaining juice.


Images: The juicer demonstrating its XL feeding tube for whole fruits and the drip-stop feature to prevent spills.
Cleaning and Maintenance
Regular cleaning ensures optimal performance and longevity of your juicer.
Quick Clean (within 90 seconds)
- After juicing, switch off and unplug the appliance.
- Disassemble the feeding tube assembly, auger, and filter.
- Rinse all detachable parts under running water. Use the cleaning brush provided for the filter to remove any pulp residue.
- Wipe the motor unit with a damp cloth. Do not immerse it in water.
Deep Cleaning (Dishwasher Safe Parts)
- All detachable parts (feeding tube, auger, filter, juice container, pulp container) are dishwasher safe.
- Place them on the top rack of your dishwasher.
- Ensure parts are completely dry before reassembling or storing.

Image: The juicer highlighting its quick clean feature, allowing for easy rinsing of parts.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Appliance does not start. | Not properly assembled or plugged in. | Ensure all parts are correctly assembled and locked. Check if the power cord is securely plugged into a working outlet. |
| Low juice yield, wet pulp. | Ingredients too soft or fed too quickly. | Feed ingredients slowly. For very soft fruits, alternate with harder fruits/vegetables. Ensure the filter is clean. |
| Appliance stops during operation. | Overload protection activated. | Switch off and unplug. Remove any blockage. Let the appliance cool down for 15-30 minutes before restarting. |
| Excessive vibration or noise. | Improper assembly or hard ingredients. | Check assembly. Ensure ingredients are cut to appropriate size. |
Specifications
- Model: HR1887/81
- Brand: Philips
- Power: 150 Watts
- Product Dimensions: 39.5D x 44W x 18.5H Centimeters
- Special Feature: Dishwasher Safe, Wide Mouth (70mm XL feeding tube)
- Blade Material: Stainless Steel
- Cord Length: 1.05 m
- Color: White
- Included Components: Juicer
Warranty and Support
The Philips Viva Collection Masticating Juicer HR1887/81 comes with a 2-year warranty from the date of purchase.
For warranty claims, technical support, or service inquiries, please contact Philips customer support. Refer to your purchase documentation for specific contact details or visit the official Philips website.
You may also consider purchasing extended warranty plans for additional coverage, such as the 1-Year Philips Extended Warranty or the 2-Year Extended Warranty Plan by Onsitego, if available at the time of purchase.