Introduction
This manual provides comprehensive instructions for the installation, setup, operation, and maintenance of your Utilitech In-Wall Digital Timer, product number #0192773 (Model TM-097 S). This device is designed to automate lighting and appliance control within your home, offering convenience and energy savings. Please read this manual thoroughly before installation and use.

Figure 1: Utilitech In-Wall Digital Timer #0192773 (Front Packaging)
This image displays the front of the product packaging for the Utilitech In-Wall Digital Timer. The timer unit, designed to fit into a standard wall plate, is visible through the clear plastic. Key features such as "Automatically adjusts for daylight saving time" and "Manual on/off override" are highlighted on the packaging.
Safety Information
WARNING: Risk of electric shock. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installing or servicing this device. If you are unsure about any part of these instructions, consult a qualified electrician.
- For indoor use only.
- Do not exceed the electrical ratings specified in this manual.
- Ensure all wire connections are secure and properly insulated.
- Neutral wire required and spare neutral wire included.
- Consult a licensed electrician if needed.
Package Contents
- Utilitech In-Wall Digital Timer (#0192773 / Model TM-097 S)
- Mounting Screws
- Wire Nuts
- Instruction Manual (this document)
Installation
Tools Required: Screwdriver, Wire Strippers, Voltage Tester.
- Turn Off Power: Locate the circuit breaker controlling the switch you are replacing and turn it OFF. Verify power is off using a voltage tester.
- Remove Existing Switch: Carefully remove the wall plate and unscrew the existing switch from the wall box. Disconnect the wires from the old switch, noting which wire was connected to which terminal.
- Identify Wires: You will typically find a Line (hot) wire, a Load wire (to the light/appliance), a Neutral wire, and a Ground wire. This timer requires a neutral wire for operation.
- Wire the Timer: Connect the wires from the wall box to the timer's corresponding wires using wire nuts. Refer to the wiring diagram (if provided with the physical product) for precise connections. Ensure the neutral wire from the wall box is connected to the timer's neutral wire.
- Mount the Timer: Carefully fold the wires into the wall box and secure the timer to the wall box using the provided screws.
- Install Wall Plate: Attach your existing rocker switch wall plate over the timer.
- Restore Power: Turn the power back ON at the circuit breaker.

Figure 2: Utilitech In-Wall Digital Timer #0192773 (Back Packaging)
This image shows the back of the product packaging, detailing electrical ratings, safety instructions, and the requirement for a neutral wire. It also lists the model number TM-097 S and UPC 827214004767.
Setup and Programming
The timer features a small digital display and buttons for programming. Specific programming steps may vary slightly, but the general process involves setting the current time and then defining your desired ON/OFF programs.
Setting Current Time and Day
- Press the SET button (or similar button) to enter time setting mode.
- Use the HOUR and MINUTE buttons to adjust the current time.
- Use the DAY button to set the current day of the week.
- Press SET again or wait for the display to return to normal operation.
Programming ON/OFF Schedules
The timer supports up to 9 ON/OFF settings (programs) per day, and automatically adjusts for daylight saving time.
- Press the PROG button to enter programming mode. The display will show "1 ON".
- Use HOUR and MINUTE buttons to set the desired ON time for program 1.
- Press PROG again. The display will show "1 OFF".
- Use HOUR and MINUTE buttons to set the desired OFF time for program 1.
- Repeat steps 1-4 for additional programs (up to 9).
- To exit programming, press the CLOCK button or wait for the display to time out.
Daylight Saving Time (DST) Adjustment
This timer automatically adjusts for Daylight Saving Time changes twice a year. No manual intervention is required for this feature.
Operating Instructions
Manual ON/OFF Override
To manually turn the connected device ON or OFF without affecting the programmed schedule, press the ON/OFF button located on the front of the timer. The timer will remain in the manually selected state until the next programmed event occurs, at which point it will resume its schedule.
Random Mode (if applicable)
Some models may include a random mode feature, often indicated by a light bulb icon or "RND" button. This mode can turn lights ON and OFF at random intervals within a set period to give the appearance of occupancy. Consult the physical product's specific button labels for this function.
Maintenance
- Cleaning: Wipe the timer's surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Power Outages: The timer has a built-in battery backup to retain settings during power outages. If the display is blank after a power outage, the battery may be depleted and require recharging (by restoring power) or replacement (if accessible).
- Inspection: Periodically check the timer and wall plate for any signs of damage or loose connections.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Timer display is blank. | No power to the timer; internal battery depleted. | Check circuit breaker. Ensure proper wiring. Allow time for internal battery to recharge once power is restored. |
| Timer does not turn ON/OFF at programmed times. | Incorrect time/day setting; programs not set correctly; manual override engaged. | Verify current time and day. Recheck programmed ON/OFF times. Ensure manual override is not active. |
| Connected device does not respond. | Loose wiring; faulty device; timer malfunction. | Turn off power and check wiring connections. Test the connected device with a standard switch. If issues persist, consult an electrician or contact support. |
| Daylight Saving Time not adjusting. | Feature not enabled or malfunction. | Ensure the timer is set to the correct region/mode for automatic DST adjustment (if applicable, though this model states it adjusts automatically). |
Specifications
- Product Number: #0192773
- Model: TM-097 S
- Brand: Utilitech
- Type: In-Wall Digital Timer
- Voltage: 125V AC, 60Hz
- General Use Rating: 15A
- Resistive Rating: 15A
- Tungsten Rating: 1000W
- Motor Rating: 1/2 HP
- Electronic Ballast: 500VA
- Standard Ballast: 120V, 60Hz, 8.3A
- Number of Settings: Up to 9 ON/OFF programs
- Features: Automatic Daylight Saving Time adjustment, Manual ON/OFF override, Astronomic features.
- Dimensions (Packaging): Approximately 7.1 x 4.9 x 2.1 inches
- Weight: Approximately 4 ounces
- UPC: 827214004767
Warranty and Support
For warranty information or technical support, please refer to the documentation included with your purchase or contact Utilitech customer service. Contact details are typically available on the manufacturer's website or product packaging.
Manufacturer: Utilitech
Distributed by: LG Sourcing Inc., P.O. Box 1535, N. Wilkesboro, NC 28659
Website: www.lgsourcing.com
Phone: 1-800-643-0067